Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:VFD7A3MS43PNSAA
VFD7A3MS43PNSAA Delta MS300 3kW 7.3A 480V Variable Frequency Drive
Manufacturer: Delta
Product No.: VFD7A3MS43PNSAA
Product Type: AC Drive
Product Origin: CN
Payment:T/T, Western Union
Weight: 1500g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Description
Product Overview
The Delta VFD7A3MS43PNSAA is a high-performance micro-vector AC drive from the MS300 series, specifically optimized for precise motor control in industrial automation. This 3kW (4HP) inverter supports both Induction Motors (IM) and Permanent Magnet (PM) motors, offering exceptional versatility for diverse machinery. With an apparent output power of 5.6 kVA and a rated output current of 7.3A, the unit features a space-saving IP20 Plate design. This drive operates within a 380-480V supply range, providing a robust power solution for high-torque applications including pumps, fans, and conveyor systems.
Technical Configuration & Efficiency Data
The hardware architecture of this drive focuses on thermal stability and energy efficiency to reduce long-term operational costs.
Power Efficiency and Loss Profiles
This module demonstrates significant energy efficiency across its operating spectrum. At 90% frequency and 100% load, power loss is managed at 128.5W (2.29% relative loss). For low-load conditions at 0% frequency and 25% current, the loss scales down to a minimal 82.5W. Additionally, the unit maintains an ultra-low standby loss of 8W, making it one of the more energy-conscious options in the micro-drive category.
Thermal and Electrical Performance
Designed for reliability in demanding environments, the drive supports a maximum operating temperature of 50°C. It is compatible with 50/60 Hz supply frequencies, ensuring seamless integration into global industrial grids. The derivative model VFD7A3MS43PNSART provides identical technical performance and electrical characteristics, ensuring consistency across different regional variants of the MS300 line.
Technical Specifications
| Feature | Specification |
|---|---|
| Model Number | VFD7A3MS43PNSAA |
| Rated Power Output | 3 kW (4 HP) |
| Rated Output Current | 7.3 A |
| Supply Voltage | 380 - 480 V (3-Phase) |
| Apparent Output Power | 5.6 kVA |
| Protection Rating | IP20 (Plate) |
| Max Operating Temp | 50 °C |
| Shipping Weight | Approx. 1.5 kg (Frame Size B) |
Installation & Engineering Guide
Successful integration of the MS300 series drive requires adherence to specific mounting and wiring protocols to ensure safety and longevity.
Mounting and Thermal Management
The compact IP20 Plate housing is ideal for side-by-side cabinet installation. To prevent overheating, ensure that the internal cooling path is unobstructed and maintain proper vertical orientation. The relative power loss profile indicates that while the unit is efficient, adequate ventilation must be provided to dissipate the 128.5W peak heat load effectively during continuous operation at 7.3A.
Electrical Protection
The drive features comprehensive protection circuits, including overcurrent, overvoltage, and ground fault detection. When wiring the 380-480V supply, use high-quality industrial grade cables and ensure proper grounding of the IP20 chassis. For PM motor applications, verify that the back-EMF constants are correctly programmed to maintain stable control throughout the frequency range.
Engineering Advantages
- Optimized Micro Footprint: Engineered for space-efficiency without compromising on torque or computational power.
- Dual Motor Support: Single-drive solution for both standard induction and high-efficiency permanent magnet motors.
- Integrated Safety: Features built-in Safe Torque Off (STO) functionality to meet modern safety standards.
- High Resolution Control: Precise 50/60 Hz frequency management for smooth acceleration and deceleration curves.
Technical FAQs
Q1: What distinguishes the -AA variant from the -RT variant?
A1: The -RT variant is a derivative model often associated with specific logistics or regional packaging standards, but it is electrically identical to the primary model.
Q2: Can this drive operate in temperatures exceeding 50°C?
A2: While the rated maximum is 50°C, operating at higher temperatures may require de-rating the output current below 7.3A to protect internal electronics.
Q3: Is the standby power consumption really as low as 8W?
A3: Yes, the MS300 series is designed with modern power-saving circuitry to minimize idle losses when the drive is not actively powering a motor.
Goşmaça spesifikasiýalar
- Black
- Gray
Scalar (V/f)
Vector
AC-powered
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
Can DCS Intelligent Regulation Fix Thermal Power Energy Imbalance?
This article explains how intelligent DCS regulation with MPC and cloud-based control solves energy-production imbala...
-
Can Continuous Automation Iteration Cut Factory Costs by 18-25%?
Static industrial control systems create hidden annual cost increases of 18-25%. Phased PLC and DCS program iteration...
-
Can Anti-Interference Hardware End 38% of Automation Downtime?
Field data from chemical, wind, and automotive plants proves that industrial hardware with full IEC 61000-4 EMC certi...
-
How Does Full-Lifecycle Management Optimize PLC and DCS Assets?
Traditional industrial asset management relies on manual logging and reactive troubleshooting, causing 15–20% annual ...
-
Can an Integrated Spare Chain Slash Downtime?
Unplanned equipment failures cost Chinese factories ¥636,000 per hour. Traditional cross-border spare procurement tak...
-
Why Do 30% of Automation Upgrades Fail Due to Integration Gaps?
This technical article explains how digital-intelligent fusion overcomes fragmented workshop operations using industr...