Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:330908-00-30-10-01-CN
Bently Nevada 330908-00-30-10-01-CN ClickLoc Probe
Manufacturer: Bently Nevada
Product No.: 330908-00-30-10-01-CN
Product Type: 3300 NSv Probe
Product Origin: USA
Payment:T/T, Western Union
Weight: 140g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
Product Overview
The 330908-00-30-10-01-CN is an industrial eddy current displacement sensor from Bently Nevada’s specialized 3300 NSv (Narrow System) series. Purpose-built for critical machinery diagnostics—including fluid-film bearing vibration, thrust position, and high-speed shaft observation—this non-contacting proximity probe excels in locations with narrow physical clearances or small target diameters. It features an elongated 3.0-inch AISI 304 stainless steel case, fully threaded without an unthreaded segment, and an integrated 1.0-meter FEP-insulated coaxial cable. This specific configuration features a miniature ClickLoc connector fitted with a rugged factory connector protector, alongside regional country-specific approvals for seamless integration into localized hazardous or regulated zones.
Core Technical Advantages
- Aggressive Chemical Resilience: Engineered with advanced material bonding that significantly outclasses legacy 3300 RAM probes, allowing long-term, direct deployment inside harsh process gas compressors.
- Precision Side-View Dynamics: Exceptional side-view immunity ensures tight mechanical installations can occur near cross-sectional walls without side-loading interference or corrupted gap calibration.
- Connector Protection Shielding: The 01 Option Code supplies a specialized connector protector over the miniature ClickLoc junction, keeping the high-frequency coaxial mating point secure against fluid ingress and mechanical strain.
- Extended Installation Geometry: A 3.0-inch overall case length provides deep penetration clearance through outer machine blocks or thick bracket housings, ensuring the probe tip aligns perfectly with the target.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Manufacturer | Bently Nevada (Baker Hughes) |
| Full Part Number | 330908-00-30-10-01-CN |
| Transducer Product Line | 3300 NSv Proximity Transducer System |
| Mounting Thread Profile | 3/8-24 UNF (Unarmored) |
| Case Length Dimension (-30) | 3.0 Inches overall case length / 0.0 in unthreaded |
| Total Cable Length Option (10) | 1.0 Meter (39 Inches) 75 Ω FEP-Insulated Coaxial |
| Connector Configuration (01) | Miniature coaxial ClickLoc connector with connector protector |
| Agency Approval Suffix (-CN) | Country Specific hazardous area certification |
| Linear Measuring Range | 1.5 mm (60 mils) — spanning 0.25 mm to 1.75 mm from target |
| Incremental Scale Factor (ISF) | 7.87 V/mm (200 mV/mil) nominal scale output |
| Probe DC Resistance (RPROBE) | 4.2Ω ± 0.5Ω (Center conductor to outer shield for 1.0m length) |
| Core Materials | Polyphenylene sulfide (PPS) tip / AISI 304 Stainless Steel case |
| Estimated Physical Weight | Approx. 34g (excluding connector protector extensions) / Package weight approx. 140g |
Engineering Installation & Maintenance
- Torque Limitations: Threading the 3/8-24 probe into place requires a recommended installation torque of 11.3 N·m (100 in·lb), absolute maximum rated at 33.9 N·m (300 in·lb). Exceeding this boundary risk cracking or deforming the stainless steel casing. The coaxial connector assembly should be tightened finger-tight up to a ceiling of 0.56 N·m (5 in·lb).
- Thread Depth Limit: Maximum thread engagement within the machinery entry port is restricted to 0.563 inches to shield the inner mechanism from over-penetration hazards.
- Minimum Cable Bend Radius: Maintain a minimum continuous bend radius of 25.4 mm (1.0 inch) when routing the 1-meter FEP coaxial line across conduits or brackets to maintain core insulation integrity.
- Target Area and Shaft Scale: The flat shaft target requires a minimum diameter of 8.9 mm (0.35 in), with a recommended minimum of 13 mm (0.5 in). If checking smaller axial shafts, expect a scale factor shift; adjusting the probe closer to the target can mitigate this variance.
Why Choose This Model
- Drop-in Heritage Compatibility: Fully interchangeable mechanically and electrically with legacy Bently Nevada 3300 RAM series equipment, enabling direct upgrades without updating control panel Proximitor monitors.
- Long-Distance Integrity: Delivers linear frequency responses of 0 to 10 kHz (+0, -3 dB typical) and can route signals across up to 305 meters (1,000 feet) of field wiring using three-conductor shielded triad cabling.
- Viton O-Ring Sealing: Incorporates an internal Viton O-ring pressure barrier built into the case frame, safeguarding structural gas boundaries under heavy machine pressure differentials.
- Lightweight Structural Integration: Weighing only approximately 34 grams, this lightweight sensor minimizes parasitic mass loading on small bracket assemblies while remaining completely stiff and resilient under heavy machine G-forces.
Technical FAQs
Q1: What is the purpose of the "-CN" suffix on this probe configuration?
A1: The "-CN" suffix indicates that the proximity probe is certified with country-specific hazardous area and environmental approvals necessary for targeted regional regulations.
Q2: Why does this probe show a higher nominal DC resistance than the 0.5-meter models?
A2: Because this variant includes an extended 1.0-meter integral cable, the natural internal wire resistance increases the nominal scale to 4.2Ω ± 0.5Ω.
Q3: How does the connector protector function during maintenance?
A3: The pre-installed protector acts as a sleeve over the ClickLoc interconnect, preventing grease, fluids, and fine particulates from compromising the high-frequency coaxial transmission signal path.
Goşmaça spesifikasiýalar
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
Can a Multi-Vendor PM Checklist Cut PLC Downtime?
This article presents a standardized annual preventive maintenance checklist for mixed-vendor industrial control envi...
-
Why Emerson Hot Redundancy Retrofit Slashes Downtime by 96%?
Process plants relying on GE Fanuc single PLCs face 47% of unplanned outages from controller failure, costing $38,000...
-
Cut Migration Engineering Hours by 60% – How Does It Work?
This technical guide examines the operational risks and engineering overhead of maintaining separate GE Proficy HMI a...
-
Is Your 1756 Supply Chain Risking Production?
Counterfeit 1756 modules cause 68% of unplanned PLC downtime. This guide covers a four-step verification method, real...
-
Why Do 72% of Analog Loop Failures Trace Back to Wiring Errors?
This technical guide presents field-verified wiring protocols for integrating Emerson Rosemount 4–20mA HART transmitt...
-
GE Fanuc VersaMax: Did It Replace Obsolete ABB AC500-ECO?
This technical case study details a complete control system retrofit for a 1200m³/day municipal water plant. Our team...