Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:330908-00-15-05-02-00
Bently Nevada 330908-00-15-05-02-00 1.5-Inch Case Probe
Manufacturer: Bently Nevada
Product No.: 330908-00-15-05-02-00
Product Type: 3300 NSv Probe
Product Origin: USA
Payment:T/T, Western Union
Weight: 150g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
Product Overview
The 330908-00-15-05-02-00 is a high-reliability industrial proximity probe from Bently Nevada’s specialized 3300 NSv (Narrow System) series. Engineered primarily for fluid-film bearing vibration, thrust position, and speed tracking, this non-contacting eddy current probe is optimized for applications with restricted installation space or small target shafts. It features a compact 1.5-inch AISI 304 stainless steel case, an unthreaded length profile, and an integral 0.5-meter FEP-jacketed coaxial cable terminating in a miniature ClickLoc connector. This model offers high-integrity physical sealing and enhanced chemical resistance, allowing it to interface seamlessly with industrial process compressors and high-speed turbomachinery.
Core Technical Advantages
- Enhanced Chemical Resistance: Upgraded material construction provides significantly higher chemical resilience compared to legacy 3300 RAM probes, making it safe for harsh process gas environments.
- Optimized Cross-Talk Suppression: Superior side-view characteristics over previous 3000-series 190 probes ensure precise gap measurements without interference from adjacent mechanical structures.
- ClickLoc Interconnect Security: Fitted with a miniature coaxial ClickLoc connector (02 Option Code) that establishes an IP67-rated, vibration-proof mating link with extension cables.
- Wide Thermal Range Performance: Certified to operate stably across extreme temperature boundaries from -52°C up to +177°C, maintaining signal consistency under heavy machinery operational cycles.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Manufacturer | Bently Nevada (Baker Hughes) |
| Full Part Number | 330908-00-15-05-02-00 |
| Transducer Product Line | 3300 NSv Proximity Transducer System |
| Mounting Thread Size | 3/8-24 UNF (Without protective armor) |
| Case Length Dimension (-15) | 1.5 Inches (Overall case length) / 0 in Unthreaded |
| Total Cable Length Option (05) | 0.5 Meters (20 Inches) 75 Ω FEP-Insulated Coaxial |
| Linear Measuring Range | 1.5 mm (60 mils) — spanning 0.25 mm to 1.75 mm from target |
| Incremental Scale Factor (ISF) | 7.87 V/mm (200 mV/mil) nominal scale output |
| Probe DC Resistance (RPROBE) | 4.0Ω ± 0.5Ω (Center conductor to outer shield) |
| Recommended Gap Setting | 1.0 mm (40 mils) standard installation distance |
| Probe Materials | Polyphenylene sulfide (PPS) tip / AISI 304 Stainless Steel case |
| Estimated Physical Weight | 14g to 150g (Lightweight sensor body design) |
Engineering Installation & Maintenance
- Torque Limitations: When executing standard mounting into a threaded 3/8-24 port, apply the recommended seating installation torque of 11.3 N·m (100 in·lb). Absolute maximum rated installation torque must not exceed 33.9 N·m (300 in·lb) to prevent housing distortion. For the miniature connector-to-connector interface, use finger-tight execution up to a maximum limit of 0.56 N·m (5 in·lb).
- Thread Engagement Bound: Ensure that the maximum length of thread engagement inside the machine housing does not exceed 0.563 inches to prevent internal mechanics collision.
- Cable Bending Parameters: Maintain a minimum structural bend radius of 25.4 mm (1.0 inch) across the entire 0.5-meter FEP coaxial line during routine field wiring routing to eliminate core shielding micro-fractures.
- Target Size Guidelines: For optimum scale factor calibration, the minimum flat shaft target area diameter is 8.9 mm (0.35 in), with a recommended standard minimum of 13 mm (0.5 in). Axial position reading on smaller surfaces requires reduced gaps to maintain scale factor fidelity.
Why Choose This Model
- Backward Compatibility: Physically and electrically interchangeable with previous-generation Bently Nevada 3300 RAM proximity components, enabling easy retrofitting without modifying existing control room monitors.
- High-Frequency Signal Path: Supports a broad frequency response from 0 to 10 kHz (+0, -3 dB typical), allowing reliable vibration diagnosis up to 305 meters (1,000 feet) away using heavy-gauge three-conductor shielded triad field cables.
- Differential Pressure Sealing: Equipped with an internal Viton O-ring seal specifically designed to contain high differential pressures between the probe tip and outer case framework.
Technical FAQs
Q1: What does the -00 option code signify at the end of the part configuration?
A1: The final -00 suffix denotes that specialized agency hazardous approvals are not required for this standard stock specification model layout.
Q2: What is the Deviation from Best Fit Straight Line (DSL) error metric for this probe?
A2: The module maintains tight calibration tolerances, featuring a DSL variance of less than ±0.06 mm (±2.3 mils) over its entire 1.5 mm tracking curve.
Q3: Is this product brand new or reconditioned surplus stock?
A3: We supply this item exclusively as 100% brand new and original unit condition inside its authentic factory protective packing, covered by a full 12-month mechanical performance warranty.
Goşmaça spesifikasiýalar
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
Can a Multi-Vendor PM Checklist Cut PLC Downtime?
This article presents a standardized annual preventive maintenance checklist for mixed-vendor industrial control envi...
-
Why Emerson Hot Redundancy Retrofit Slashes Downtime by 96%?
Process plants relying on GE Fanuc single PLCs face 47% of unplanned outages from controller failure, costing $38,000...
-
Cut Migration Engineering Hours by 60% – How Does It Work?
This technical guide examines the operational risks and engineering overhead of maintaining separate GE Proficy HMI a...
-
Is Your 1756 Supply Chain Risking Production?
Counterfeit 1756 modules cause 68% of unplanned PLC downtime. This guide covers a four-step verification method, real...
-
Why Do 72% of Analog Loop Failures Trace Back to Wiring Errors?
This technical guide presents field-verified wiring protocols for integrating Emerson Rosemount 4–20mA HART transmitt...
-
GE Fanuc VersaMax: Did It Replace Obsolete ABB AC500-ECO?
This technical case study details a complete control system retrofit for a 1200m³/day municipal water plant. Our team...