Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:VFD150C43A-21
VFD150C43A-21 Delta C2000 Series 15KW Motor Drive Unit
Manufacturer: Delta
Product No.: VFD150C43A-21
Product Type: AC Drive
Product Origin: CN
Payment:T/T, Western Union
Weight: 5400g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Delta VFD150C43A-21 C2000 Series AC Drive
The VFD150C43A-21 is a Delta C2000 series variable frequency drive. This compact, 20 HP drive is designed for reliable motor control in industrial environments. It features a built-in braking chopper for effective motor deceleration.
Core Technical Specifications
- Brand & Model: Delta VFD150C43A-21
- Product Series: C2000
- Input Power: 3-Phase, 460V AC
- Output Power: 20 HP (15 kW)
- Output Current (Heavy Duty): 32 A
- Frame Size: B
- Key Feature: Built-in braking chopper (requires external braking resistor).
- Protection Rating: IP20
Physical Data & Features
- Weight: 11.88 lbs (5.4 kg)
- Dimensions: 190 mm x 190 mm x 320 mm (7.48" x 7.48" x 12.6")
- Built-in EMC Filter: No (external filter may be required for compliance).
- Built-in DC Reactor: No
- Communication: CANopen card not included (optional).
- Application: Suitable for pumps, fans, conveyors, and other applications requiring variable speed control of 20HP motors.
Frequently Asked Questions
-
Q: What is the difference between "Heavy Duty" and "Super Heavy Duty" current ratings?
A> "Heavy Duty" (32A) is for constant torque applications (e.g., conveyors, positive displacement pumps). "Super Heavy Duty" (24A) is for variable torque applications (e.g., centrifugal fans/pumps) where lower current is acceptable. -
Q: How do I use the built-in braking chopper?
A> The chopper is ready to connect to an external dynamic braking resistor. You must select and install a properly sized resistor to dissipate the braking energy. -
Q: What does the "-21" suffix indicate?
A> It typically denotes a specific hardware version or feature set. In this case, it often indicates a 460V input model with specific control options.
Additional Specifications
- Black
- Gray
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Can DCS Intelligent Regulation Fix Thermal Power Energy Imbalance?
This article explains how intelligent DCS regulation with MPC and cloud-based control solves energy-production imbala...
-
Can Continuous Automation Iteration Cut Factory Costs by 18-25%?
Static industrial control systems create hidden annual cost increases of 18-25%. Phased PLC and DCS program iteration...
-
Can Anti-Interference Hardware End 38% of Automation Downtime?
Field data from chemical, wind, and automotive plants proves that industrial hardware with full IEC 61000-4 EMC certi...
-
How Does Full-Lifecycle Management Optimize PLC and DCS Assets?
Traditional industrial asset management relies on manual logging and reactive troubleshooting, causing 15–20% annual ...
-
Can an Integrated Spare Chain Slash Downtime?
Unplanned equipment failures cost Chinese factories ¥636,000 per hour. Traditional cross-border spare procurement tak...
-
Why Do 30% of Automation Upgrades Fail Due to Integration Gaps?
This technical article explains how digital-intelligent fusion overcomes fragmented workshop operations using industr...
