Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:V18345-2010421001
V18345-2010421001 | ABB TZIDC Positioner Analog Feedback
Manufacturer: ABB
Product No.: V18345-2010421001
Product Type: Valve Positioner Module
Product Origin: Sweden
Payment:T/T, Western Union
Weight: 1700g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
Product Overview
The V18345-2010421001 is a TZIDC electro-pneumatic positioner from ABB, designed for precise valve control on linear and rotary actuators. Features 4–20 mA two-wire input, HART communication, double-acting fail-safe output, and plug-in analog position feedback (4–20 mA). Aluminum IP65/NEMA 4X housing. Weight: 1.7 kg.
Analog Position Feedback Module
Range 4–20 mA with configurable split ranges. Two-wire circuitry, power supply 24 V DC (10–30 V DC) or 48 V DC (20–48 V DC, no explosion protection). Action direct or reverse (configurable). Characteristic deviation <1%. Without a signal from the positioner, the module sets output to >20 mA (alarm level).
Technical Specifications
| Parameter | Specification |
|---|---|
| Part Number | V18345-2010421001 |
| Manufacturer | ABB |
| Type | TZIDC Electro-Pneumatic Positioner |
| Input Signal | 4–20 mA (two-wire) |
| Communication | HART, LKS local connector |
| Output / Safe Position | Double acting, fail safe |
| Analog Position Feedback | 4–20 mA, configurable split ranges |
| Feedback Power Supply | 24 V DC (10–30 V DC) / 48 V DC (20–48 V DC, non-Ex) |
| Feedback Deviation | <1% |
| Supply Pressure | 1.4–6 bar (20–90 psi) |
| Air Consumption | <0.03 kg/h / 0.015 scfm |
| Housing Material | Aluminum, varnished, RAL 9005 |
| Protection Class | IP65 / NEMA 4X |
| Pneumatic Connections | G 1/4 or 1/4-18 NPT |
| Electrical Connections | Cable: 1/2-14 NPT; Air pipe: 1/4-18 NPT |
| Digital Input | 0–5 V DC (logical 0), 11–30 V DC (logical 1) |
| Digital Output | 5–11 V DC (NAMUR DIN 19234) |
| Weight | 1.7 kg |
Installation & Maintenance
Mounting
Mount to linear actuators per DIN/IEC 534/NAMUR or rotary actuators per VDI/VDE 3845. Mechanical position indicator provides visual feedback. Mounting orientation has no measurable influence on performance.
Air Supply
Use instrument air free of oil, water, and dust. Supply pressure 1.4–6 bar (20–90 psi). Do not exceed actuator max operating pressure. Air consumption <0.03 kg/h independent of supply pressure.
Electrical Connection
Connect 4–20 mA two-wire signal. HART communication via 20 mA signal line. Analog position feedback module provides 4–20 mA output proportional to valve position. Cable entry: 1/2-14 NPT.
Engineering Advantages
Double-Acting Fail-Safe
Fail-safe output moves actuator to safe position on electrical power failure. For double-acting actuators, output 1 is depressurized and output 2 is pressurized, ensuring reliable safety operation.
Integrated Analog Feedback
Plug-in analog position feedback module (4–20 mA) provides accurate valve position indication. Configurable split ranges and direct/reverse action. Outputs >20 mA alarm level when no positioner signal is present.
Robust Environmental Protection
IP65/NEMA 4X aluminum housing with electrostatic epoxy varnish resists corrosion and dust. Mechanical position indicator and HART communication enable easy commissioning and remote diagnostics.
Technical FAQs
Q1: What is the fail-safe behavior on electrical power failure?
A1: Double-acting fail-safe. Output 1 is depressurized and the valve moves to its safe position. The second output is additionally pressurized.
Q2: Does this model include analog position feedback?
A2: Yes. The plug-in analog position feedback module provides 4–20 mA output with configurable split ranges and <1% deviation.
Q3: What supply pressure range does this positioner require?
A3: 1.4–6 bar (20–90 psi). Do not exceed the maximum operating pressure of the actuator.
Goşmaça spesifikasiýalar
- Kümüş
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
How Can You Tune GE RX3i and RX7i Ethernet for Heavy Industry?
Intermittent Ethernet timeouts on GE RX3i and RX7i controllers are among the hardest faults in heavy process plants, ...
-
Why Does FCS Redundancy Not Protect Your HIS Configuration?
This article examines the operational risks of Yokogawa CENTUM VP HIS lockups and explains why FCS controller re...
-
How Does 1756 Analog I/O Calibration Drift Affect PLC Accuracy?
This article examines calibration drift in Allen-Bradley ControlLogix 1756 analog I/O modules, presenting quanti...
-
Why Do 31% of ABB 800xA S800 IO Hot Swaps Fail in DCS Systems?
ABB 800xA S800 hot swap failures rarely stem from defective hardware. Field data from 142 card replacement jobs shows...
-
How Do You Diagnose Degraded MTL Surge Protection Devices?
This article presents field-proven diagnostic checks, aging benchmarks, and installation rules for MTL surge pro...
-
How Can You Stop Nuisance Trips on Bently Nevada TSI Systems?
Nuisance trips on Bently Nevada TSI racks cost power and oil & gas plants $18,000 to $45,000 per event and occur ...