Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:V18347-2041150001
TZIDC-120 Foundation Fieldbus Positioner ABB | V18347-2041150001
Manufacturer: ABB
Product No.: V18347-2041150001
Product Type: Valve Positioner Module
Product Origin: Sweden
Payment:T/T, Western Union
Weight: 1700g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
ABB V18347-2041150001 TZIDC-120 Electro-Pneumatic Positioner
Product Overview
ABB V18347-2041150001 is a TZIDC-120 intelligent, configurable electro-pneumatic positioner for FOUNDATION Fieldbus communication. Features varnished aluminum case with mechanical position indicator and IP65 (NEMA 4X) protection. Mounts to linear actuators per DIN/IEC 534/NAMUR or rotary actuators per VDI/VDE 3845. ATEX EEx ia IIC T6 intrinsically safe certified. Single acting fail safe action. Cable connection M20x1.5 and air pipe 1/4-18 NPT. Weight 1.7 kg.
Model Number Decoder
| Position | Code | Meaning |
|---|---|---|
| Base | V18347 | TZIDC-120 Positioner for FOUNDATION Fieldbus |
| Case/Mounting | 20 | Aluminum case with mechanical position indicator |
| Input/Communication | 4 | FOUNDATION Fieldbus |
| Explosion Protection | 1 | ATEX EEx ia IIC T6 |
| Output/Safe Position | 1 | Single acting, fail safe |
| Connections | 5 | Cable M20x1.5, Air 1/4-18 NPT |
| Shutdown Function | 0 | Without |
| Mech Feedback Kit | 00 | Without |
| Design | 1 | Standard |
Technical Specifications
| Parameter | Value |
|---|---|
| Brand | ABB |
| Model | V18347-2041150001 |
| Type | TZIDC-120 Electro-Pneumatic Positioner |
| Communication | FOUNDATION Fieldbus |
| Explosion Protection | ATEX EEx ia IIC T6 intrinsically safe |
| Action | Single Acting, Fail Safe |
| Position Indicator | Mechanical, built in |
| Protection Class | IP65, NEMA 4X |
| Housing Material | Aluminum, epoxy resin varnish |
| Electrical Connection | M20x1.5 (2 threads, 1 gland, 1 plug) |
| Pneumatic Connection | G 1/4 or 1/4-18 NPT |
| Screw Terminals | Max 1.0 mm² (options), max 2.5 mm² (analog) |
| Operating Temperature | 40°C to +85°C |
| Temperature with SJ2-S1N | 25°C to +85°C |
| Humidity Operational | 95% annual average, condensation permissible |
| Humidity Storage | 75% annual average, non condensing |
| Weight | 1.7 kg |
Installation
Mount on linear actuators per DIN/IEC 534/NAMUR or rotary actuators per VDI/VDE 3845. Connect FOUNDATION Fieldbus cable at M20x1.5 cable entry. Use 1 thread with cable gland and 1 with pipe plug. Connect air supply at G 1/4 or 1/4-18 NPT. Do not expose terminals to strain. For ATEX intrinsically safe installation, observe EEx ia IIC T6 temperature limits and certified barriers. Verify IP65 seal after installation.
Features
TZIDC-120 intelligent configurable positioner with indicator and operator panel. FOUNDATION Fieldbus digital communication for advanced diagnostics. Built in mechanical position indicator for visual feedback. ATEX EEx ia IIC T6 intrinsically safe certification. Single acting fail safe action for power failure safety. Aluminum case with epoxy resin varnish IP65 NEMA 4X. Operating temperature 40°C to +85°C. Humidity tolerance 95% with condensation permissible. Weight 1.7 kg.
FAQ
Q1: What communication protocol does this positioner use?
A1: FOUNDATION Fieldbus digital communication. Supports advanced diagnostics and remote configuration via the fieldbus network.
Q2: What is the explosion protection rating?
A2: ATEX EEx ia IIC T6 intrinsically safe. Suitable for Zone 1 hazardous area installation with certified barriers.
Q3: What is the action type and temperature range?
A3: Single acting fail safe action. Operating temperature 40°C to +85°C. Humidity 95% annual average with condensation permissible.
Goşmaça spesifikasiýalar
- Kümüş
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
What Logic Changes Cut SIS False Trips by 94%?
This article examines practical logic modification and parameter tuning methods for ABB 800xA HI SIL3 safety ins...
-
Why Do FTE Redundancy Failovers Lock Up in DCS?
Honeywell FTE delivers sub-500 ms failover for Experion PKS, yet field records show 38% of outages stem from installa...
-
How Does the Bently Nevada 3500/42M Vibration Module Drift?
This technical guide examines the Bently Nevada 3500/42M vibration module within industrial automation architect...
-
What Causes IC694MDL Fault Codes in GE RX3i PLC Systems?
This guide explains GE RX3i IC694MDL discrete I/O fault codes, key electrical parameters, ESD and torque requirements...
-
What CFC Rules Cut PCS7 Batch Abort Rates Fast?
This article presents enforceable CFC programming governance rules for Siemens PCS7 DCS batch plants, covering b...
-
What Makes the 1769-L3ER Ideal for Compact Skid Automation?
This guide explains how the Allen-Bradley 1769 CompactLogix L3ER bridges the gap between micro PLCs and large DC...