Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:TSXDMZ28DT
TSXDMZ28DT Schneider | 16 Input 12 Output Module | 24VDC
Manufacturer: Schneider
Product No.: TSXDMZ28DT
Product Type: I/O Base
Product Origin: FR
Payment:T/T, Western Union
Weight: 425g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
Product Overview
The Schneider TSXDMZ28DT is a discrete solid state I/O base designed for Modicon TSX Micro automation platforms. It provides 16 discrete inputs and 12 discrete outputs operating at 24V DC with positive logic. Drawing 132 mA, this module delivers 3.5W power dissipation per module and 0.15W per channel. Weighing 0.425 kg, it suits compact industrial control panels.
Technical Configuration
Inputs require at least 11V for state 1 and less than 5V for state 0, with 7 mA input current and 3.4 Ohm impedance. Inputs accept 2-wire and 3-wire proximity sensors. Outputs maintain 19-30V with 0.625A current limit and 48 Ohm load impedance. Protection features include zener diode overvoltage protection, current limiter and electronic circuit breaker short-circuit protection, and reverse polarity diode.
Technical Specifications
| Parameter | Value |
|---|---|
| Manufacturer | Schneider Electric |
| Product Line | Modicon TSX Micro |
| Part Number | TSXDMZ28DT |
| EAN | 3389110540451 |
| Product Type | Discrete solid state I/O base DC |
| Discrete Inputs | 16 (1 HE-10 connector) |
| Discrete Outputs | 12 (screw terminal block) |
| Operating Voltage | 24 V DC |
| Input Voltage Limits | ≥ 11 V at state 1, < 5 V at state 0 |
| Input Current | 7 mA |
| Input Impedance | 3.4 Ohm |
| Output Voltage Limits | 19-30 V |
| Output Current Limits | 0.625 A |
| Max Leakage Current | 0.5 mA at state 0 |
| Residual Voltage | 0.3 V |
| Load Impedance | 48 Ohm |
| Switching Frequency | < 0.6/LI² Hz |
| Output Response Time | ≤ 0.5 ms |
| Input Response Time | 0.1...7.5 ms |
| Isolation Voltage | 1500 V for 1 second |
| Current Consumption | 132 mA |
| Power Dissipation | 3.5 W by module, 0.15 W by channel, 5 W input |
| Paralleling of Outputs | Yes, 2 maximum |
| Dimensions (H x W x L) | 5.5 x 18.0 x 26.0 cm |
| Net Weight | 0.425 kg (0.937 lbs) |
| Operating Temperature | -20°C to 55°C |
| Standards | IEC 1131-2 Type 1 |
Installation Guide
Mount the module into a compatible TSX Micro PLC rack using the 1 HE-10 connector for inputs and screw terminal blocks for outputs. Verify input voltage reaches at least 11V for state 1 activation. Confirm output loads do not exceed 0.625A and maintain minimum 48 Ohm impedance. Connect 2-wire or 3-wire proximity sensors to the discrete inputs. Ensure proper grounding to preserve the 1500V isolation rating.
Engineering Advantages
This module combines 16 inputs and 12 outputs in a single compact unit, reducing panel space requirements. Solid state outputs deliver fast 0.5 ms response times for precise control. Triple protection (overvoltage, short-circuit, reverse polarity) safeguards connected equipment. Paralleling up to 2 outputs supports higher current load applications. Wide -20°C to 55°C operating range suits diverse industrial conditions.
Technical FAQs
Q1: How many inputs and outputs does the TSXDMZ28DT provide?
A1: This module includes 16 discrete inputs and 12 discrete outputs operating at 24V DC with positive logic.
Q2: What protection features are integrated into the outputs?
A2: Outputs include zener diode overvoltage protection, current limiter and electronic circuit breaker short-circuit protection, and reverse polarity diode.
Q3: What is the output response time?
A3: The TSXDMZ28DT delivers ≤ 0.5 ms output response time for both state transitions.
Goşmaça spesifikasiýalar
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
How to Diagnose GE PACSystem PLC Faults Fast?
GE PACSystem PLC faults disrupt factory automation and process control. This article explains field-proven diagnosis ...
-
How Does ABB Robot Integration Boost Automotive Throughput?
ABB robot integration helps automotive plants cut material handling stoppages and raise throughput. Success depends o...
-
How Does Bently Nevada Vibration Analysis Catch Faults?
Bently Nevada vibration analysis helps industrial automation teams detect rotating machinery faults early by combinin...
-
How Do GE Edge Gateways Enable Zero-Downtime Data Collection?
GE industrial edge gateways let plants collect real-time PLC and DCS data without stopping production. They read lega...
-
How Does Honeywell SCADA Unify Multi-Site Manufacturing?
Honeywell SCADA enables manufacturers to unify monitoring across three to eight distributed plants while preserv...
-
How Do Eddy Current Probes Protect Rotating Machinery?
Bently Nevada eddy current proximity sensors deliver precise shaft displacement data for turbine and compressor prote...