Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:TSXCTY2A
TSXCTY2A Schneider Counter Module 40kHz 2 Channel TSX Micro
Manufacturer: Schneider
Product No.: TSXCTY2A
Product Type: Counter Module
Product Origin: FR
Payment:T/T, Western Union
Weight: 320g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
Schneider Electric TSXCTY2A Counter Module
Product Overview
The Schneider Electric TSXCTY2A is an auxiliary output counter module designed for TSX Micro and Modicon Premium PLCs. It features 2 channels with 40 kHz counting frequency and operates under EN/IEC 61131 standards. The module supports 2/3-wire proximity sensors (PNP/NPN) and incremental encoders. Weight is 0.32 kg (0.71 lbs).
Specifications
| Parameter | Value |
|---|---|
| Brand | Schneider Electric |
| Model | TSXCTY2A |
| Product Line | TSX Micro / Modicon Premium |
| Product Type | Counter Module / Auxiliary Output Module |
| Channels | 2 |
| Counting Frequency | 40 kHz |
| Electrical Circuit Type | Auxiliary Output EN/IEC 61131 |
| Cycle Time | 5 ms |
| Response Time | < 2.5 ms |
| Input Logic | Current Sink (Positive Logic) |
| Input Compatibility | 2/3-wire PNP/NPN sensors, Incremental encoder (10-30V totem pole, 5V DC RS422) |
| Sensor Input Voltage | 24 V, 18 mA |
| Auxiliary Input | 24 V, 7 mA (preset, enable, read) |
| Encoder Input | 5 V, 18 mA |
| Voltage State 1 (Sensors) | ≥ 11 V |
| Voltage State 1 (Encoder) | ≥ 2.4 V |
| Voltage State 0 (Sensors) | ≤ 5 V |
| Voltage State 0 (Encoder) | ≤ 1.2 V |
| Output Voltage | 24 VDC |
| Nominal Output Current | 0.5 A |
| Output Voltage Limits | 19-30 V |
| Power Dissipation | 4.5-6 W |
| Current Consumption | 280 mA @ 5 VDC, 30 mA @ 24 VDC |
| Module Format | Standard |
| Local Signalling | RUN, I/O, ERR, 2x CH LEDs |
| Electrical Connection | 1 x HE-10 (20 pins), 2 x SUB-D 15 |
| Operating Temperature | 0 to 60 °C |
| Storage Temperature | -25 to 70 °C |
| Relative Humidity | 5-95% (non-condensing) |
| Weight | 0.32 kg (0.71 lbs) |
| EAN | 3389110756975 |
Key Features
- 2 channels with 40 kHz counting frequency
- Complies with EN/IEC 61131 standards
- Supports 2/3-wire PNP/NPN proximity sensors
- Compatible with incremental encoders (10-30V totem pole, 5V DC RS422)
- Response time under 2.5 ms for prompt reactions
- 24 VDC output with 0.5 A nominal current
- Thermal overload and short-circuit protection
- Reverse polarity protection via reverse diode
- Diagnostic LEDs for RUN, I/O, ERR, and channel status
Installation Notes
Install the module in a TSX Micro or Modicon Premium PLC rack. Connect sensors using the HE-10 20-pin connector or SUB-D 15 connectors. Ensure input voltage limits are observed: 19-30 V for sensors and auxiliary inputs, 5.5 V maximum for encoder inputs. The module provides 24 VDC output for connected devices. Maintain operating temperature between 0 and 60 °C with 5-95% relative humidity (non-condensing).
FAQs
Q1: What is the counting frequency of the TSXCTY2A?
A1: 40 kHz across 2 channels.
Q2: What input types are compatible with this module?
A2: 2/3-wire PNP/NPN proximity sensors and incremental encoders (10-30V totem pole or 5V DC RS422).
Q3: What is the output rating of this module?
A3: 24 VDC output with 0.5 A nominal current and 19-30 V output voltage limits.
Goşmaça spesifikasiýalar
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
How to Diagnose GE PACSystem PLC Faults Fast?
GE PACSystem PLC faults disrupt factory automation and process control. This article explains field-proven diagnosis ...
-
How Does ABB Robot Integration Boost Automotive Throughput?
ABB robot integration helps automotive plants cut material handling stoppages and raise throughput. Success depends o...
-
How Does Bently Nevada Vibration Analysis Catch Faults?
Bently Nevada vibration analysis helps industrial automation teams detect rotating machinery faults early by combinin...
-
How Do GE Edge Gateways Enable Zero-Downtime Data Collection?
GE industrial edge gateways let plants collect real-time PLC and DCS data without stopping production. They read lega...
-
How Does Honeywell SCADA Unify Multi-Site Manufacturing?
Honeywell SCADA enables manufacturers to unify monitoring across three to eight distributed plants while preserv...
-
How Do Eddy Current Probes Protect Rotating Machinery?
Bently Nevada eddy current proximity sensors deliver precise shaft displacement data for turbine and compressor prote...