Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:TSXASY800
TSXASY800 Schneider Analog Output Module 8 Channel 13-Bit
Manufacturer: Schneider
Product No.: TSXASY800
Product Type: Analog Output Module
Product Origin: FR
Payment:T/T, Western Union
Weight: 460g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
Schneider Electric TSXASY800 Analog Output Module
Product Overview
The Schneider Electric TSXASY800 is an analog output module for the TSX Micro and Modicon Premium PLC platforms. It features 8 analog output channels with 13-bit + sign conversion, supporting current (0-20 mA, 4-20 mA) and voltage (±10 V) outputs. The module provides 1000 Vrms isolation between channels and bus/ground. Weight is 0.46 kg (1.01 lbs).
Specifications
| Parameter | Value |
|---|---|
| Brand | Schneider Electric |
| Model | TSXASY800 |
| Product Line | TSX Micro / Modicon Premium |
| Product Type | Analog Output Module |
| Output Channels | 8 |
| Output Types | Current (0-20 mA, 4-20 mA), Voltage (±10 V) |
| A/D Conversion | 13 bits + sign (±10 V), 13 bits (current) |
| Conversion Time | 5 ms |
| Measurement Resolution | 1.28 mV (±10 V), 2.56 µA (current) |
| Accuracy (25 °C) | 0.14% (±10 V), 0.21% (current) |
| Accuracy (0-60 °C) | 0.28% (±10 V), 0.52% (current) |
| Isolation (Channels to Bus) | 1000 Vrms |
| Isolation (Channels to Ground) | 1000 Vrms |
| Output Voltage Limits | ≤ 30 V |
| Load Impedance (Current) | < 600 Ω (0-20 mA, 4-20 mA) |
| Load Impedance (Voltage) | > 1000 Ω (±10 V) |
| Max Load Inductance | 300 µH |
| Max Load Capacitance | 0.1 µF |
| Protection | Short-circuit, Overload |
| Electrical Connection | 1 x SUB-D 25 connector |
| Current Consumption | 200 mA @ 5 VDC, 300 mA @ 24 VDC |
| Power Consumption | 5 W |
| Module Format | Standard |
| Protection Rating | IP20 |
| Operating Temperature | 0 to 60 °C |
| Storage Temperature | -25 to 70 °C |
| Relative Humidity (Operation) | 10-95% (non-condensing) |
| Weight | 0.46 kg (1.01 lbs) |
| EAN | 3389110876369 |
| Country of Origin | France (FR) |
Certifications
- UL 508, CSA C22.2 No 142
- CSA C22.2 No 213 Class I Division 2 Groups A, B, C, D
- IEC 61131-2
- 93/68/EEC, 73/23/EEC, 89/336/EEC, 92/31/EEC
- Marine: BV, RINA, DNV, LR, ABS, RMRS, GL
- CE Marked
Key Features
- 8 analog output channels
- Supports current (0-20 mA, 4-20 mA) and voltage (±10 V) outputs
- 13-bit + sign conversion for precise output
- 1000 Vrms isolation between channels and bus/ground
- Fast response time of 1 ms per channel
- Short-circuit and overload protection
- Measurement resolution 1.28 mV (±10 V), 2.56 µA (current)
- Single SUB-D 25 connector for electrical connection
- Marine certified (BV, RINA, DNV, LR, ABS, RMRS, GL)
- Class I Division 2 hazardous location approved
- IP20 protection rating
Installation Notes
Install the module in a TSX Micro or Modicon Premium PLC rack. Connect field wiring using the SUB-D 25 connector. For current outputs, ensure load impedance is below 600 Ω. For voltage outputs, load impedance must exceed 1000 Ω. Maximum load inductance is 300 µH and maximum load capacitance is 0.1 µF. Maintain operating temperature between 0 and 60 °C with relative humidity 10-95% (non-condensing). The module requires 24 VDC power supply and consumes 5 W.
FAQs
Q1: How many output channels does the TSXASY800 have?
A1: 8 analog output channels.
Q2: What output types does this module support?
A2: Current (0-20 mA, 4-20 mA) and voltage (±10 V) outputs.
Q3: What is the response time per channel?
A3: 1 ms per channel.
Goşmaça spesifikasiýalar
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
How to Diagnose GE PACSystem PLC Faults Fast?
GE PACSystem PLC faults disrupt factory automation and process control. This article explains field-proven diagnosis ...
-
How Does ABB Robot Integration Boost Automotive Throughput?
ABB robot integration helps automotive plants cut material handling stoppages and raise throughput. Success depends o...
-
How Does Bently Nevada Vibration Analysis Catch Faults?
Bently Nevada vibration analysis helps industrial automation teams detect rotating machinery faults early by combinin...
-
How Do GE Edge Gateways Enable Zero-Downtime Data Collection?
GE industrial edge gateways let plants collect real-time PLC and DCS data without stopping production. They read lega...
-
How Does Honeywell SCADA Unify Multi-Site Manufacturing?
Honeywell SCADA enables manufacturers to unify monitoring across three to eight distributed plants while preserv...
-
How Do Eddy Current Probes Protect Rotating Machinery?
Bently Nevada eddy current proximity sensors deliver precise shaft displacement data for turbine and compressor prote...