Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:TSXAEY1600
TSXAEY1600 Schneider Analog Input Module 16 Channel 12-Bit
Manufacturer: Schneider
Product No.: TSXAEY1600
Product Type: Analog Input Module
Product Origin: FR
Payment:T/T, Western Union
Weight: 340g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
Schneider Electric TSXAEY1600 Analog Input Module
Product Overview
The Schneider Electric TSXAEY1600 is a high-level analog input module for the TSX Micro and Modicon Premium PLC platforms. It features 16 analog input channels with 12-bit A/D conversion, supporting current (0-20 mA, 4-20 mA) and voltage (±10 V, 0-10 V, 0-5 V, 1-5 V) input types. The module provides 1000 Vrms isolation between channels and bus/ground. Weight is 0.34 kg (0.75 lbs).
Specifications
| Parameter | Value |
|---|---|
| Brand | Schneider Electric |
| Model | TSXAEY1600 |
| Product Line | TSX Micro / Modicon Premium |
| Product Type | Analog Input Module |
| Input Channels | 16 High-Level Analog Inputs |
| Input Types (Current) | 0-20 mA, 4-20 mA |
| Input Types (Voltage) | ±10 V, 0-10 V, 0-5 V, 1-5 V |
| A/D Conversion | 12 bits |
| Nominal Read Cycle Time | 51 ms |
| Fast Read Cycle Time | 3 ms + 3 ms per channel used |
| Measurement Error (25 °C) | 0.1% of full scale (voltage), 0.16% (current) |
| Measurement Error (0-60 °C) | 0.13% of full scale (voltage), 0.32% (current) |
| Isolation (Channels to Bus) | 1000 Vrms |
| Isolation (Channels to Ground) | 1000 Vrms |
| Input Overvoltage Protection | -15 to 15 V (state 0), -30 to 30 V (state 1) |
| Electrical Connection | 2 x SUB-D 25 connectors |
| Current Consumption | 270 mA @ 5 VDC |
| Module Format | Standard |
| Protection Rating | IP20 |
| Operating Temperature | 0 to 60 °C |
| Storage Temperature | -25 to 70 °C |
| Relative Humidity (Operation) | 10-95% (non-condensing) |
| Weight | 0.34 kg (0.75 lbs) |
| EAN | 3389110726114 |
| Country of Origin | France (FR) |
Certifications
- IEC 1131
- Marine: BV, GL, LR, DNV, RINA, ABS, RMRS
- CE Marked
Key Features
- 16 high-level analog input channels
- Supports current (0-20 mA, 4-20 mA) and voltage (±10 V, 0-10 V, 0-5 V, 1-5 V) inputs
- 12-bit analog-to-digital conversion for precise measurement
- 1000 Vrms isolation between channels and bus/ground
- Fast read cycle time: 3 ms + 3 ms per channel
- Nominal read cycle time: 51 ms
- Measurement error 0.1% of full scale at 25 °C (voltage)
- Input overvoltage protection -30 to 30 V at state 1
- Two SUB-D 25 connectors for electrical connection
- Marine certified (BV, GL, LR, DNV, RINA, ABS, RMRS)
- IP20 protection rating
Installation Notes
Install the module in a TSX Micro or Modicon Premium PLC rack. Connect field wiring using the two SUB-D 25 connectors. Observe input overvoltage limits of -15 to 15 V at state 0 and -30 to 30 V at state 1. Maintain operating temperature between 0 and 60 °C with relative humidity 10-95% (non-condensing). The 1000 Vrms isolation protects both the bus and ground paths. For marine applications, the module holds certifications from all major classification societies.
FAQs
Q1: What input types does the TSXAEY1600 support?
A1: Current inputs (0-20 mA, 4-20 mA) and voltage inputs (±10 V, 0-10 V, 0-5 V, 1-5 V).
Q2: What is the A/D conversion resolution?
A2: 12-bit analog-to-digital conversion.
Q3: What is the isolation rating of this module?
A3: 1000 Vrms between channels and bus, and 1000 Vrms between channels and ground.
Goşmaça spesifikasiýalar
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
How to Diagnose GE PACSystem PLC Faults Fast?
GE PACSystem PLC faults disrupt factory automation and process control. This article explains field-proven diagnosis ...
-
How Does ABB Robot Integration Boost Automotive Throughput?
ABB robot integration helps automotive plants cut material handling stoppages and raise throughput. Success depends o...
-
How Does Bently Nevada Vibration Analysis Catch Faults?
Bently Nevada vibration analysis helps industrial automation teams detect rotating machinery faults early by combinin...
-
How Do GE Edge Gateways Enable Zero-Downtime Data Collection?
GE industrial edge gateways let plants collect real-time PLC and DCS data without stopping production. They read lega...
-
How Does Honeywell SCADA Unify Multi-Site Manufacturing?
Honeywell SCADA enables manufacturers to unify monitoring across three to eight distributed plants while preserv...
-
How Do Eddy Current Probes Protect Rotating Machinery?
Bently Nevada eddy current proximity sensors deliver precise shaft displacement data for turbine and compressor prote...