Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:6ES7441-1AA03-0AE0
Siemens | 6ES7441-1AA03-0AE0 Communication Module Brand New
Manufacturer: Siemens
Product No.: 6ES7441-1AA03-0AE0
Product Type: Communication Module
Product Origin: DE
Payment:T/T, Western Union
Weight: 720g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
SIEMENS 6ES7441-1AA03-0AE0 SIMATIC S7-400 CP 441-1 Communication Module
The SIEMENS 6ES7441-1AA03-0AE0, also cataloged as the CP 441-1 Communication Module, operates as a single-channel point-to-point interface with variable interface modules for 20 mA (TTY), RS 232C (V.24), and RS 422/485 connections within SIMATIC S7-400 platforms.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 6ES7441-1AA03-0AE0 |
| Brand | Siemens |
| Product Type | CP 441-1 Communication Module |
| Series | SIMATIC S7-400 |
| Weight | 720 g (approx.), interface module 100 g |
| Dimensions (W x H x D) | 25 mm x 290 mm x 210 mm |
| Rated Supply Voltage | 5 VDC and 24 VDC |
| Current from Backplane Bus | 700 mA max at 5 VDC (without interface module) |
| Interface Modules | 20 mA (TTY), RS 422/485 (X.27), RS 232C (V.24) |
| Interface Module Consumption | 300 mA max at 5 V; 45 mA max at 24 V (TTY) |
| Number of Interfaces | 1, variable |
| Shielded Cable Length | 1000 m (TTY), 10 m (RS 232), 1200 m (RS 422/485) |
| Transmission Rate | 38.4 kbit/s max overall; 19.2 kbit/s max on TTY |
| Integrated Protocols | 3964 (R), ASCII, Printer |
| Connections | 8 overall |
| Configuration Software | STEP 7 with own parameter assignment forms |
| Memory per Interface | 1 to 5 kbyte parameters; 0 to 55 kbyte message texts |
Variable Interface Physics and Protocol Handling
Unit weight is approximately 720 g with an interface module at approximately 100 g, dimensions of 25 mm width, 290 mm height, and 210 mm depth. The CP 441-1 accepts interchangeable interface modules for 20 mA (TTY), RS 232C (V.24), and RS 422/485 (X.27) physics. Shielded cable lengths are limited to 1000 m for TTY, 10 m for RS 232, and 1200 m for RS 422/485. Transmission rate reaches 38.4 kbit/s on RS 422/485 and RS 232, and 19.2 kbit/s on TTY across 3964 (R), ASCII, and printer drivers. Supported printers include HP-Deskjet, HP-Laserjet, IBM-Proprinter, and user-defined models. The module supports 8 connections overall with S7 extended communication. Backplane bus current draw is 700 mA maximum at 5 VDC without an interface module; interface modules draw up to 300 mA at 5 V and 45 mA at 24 V. Parameter memory requirements on the S7-CPU memory card are 1 to 5 kbyte for parameters and 0 to 55 kbyte for message texts. Configuration uses STEP 7 with dedicated parameter assignment forms. A configuration package is included on CD.
Frequently Asked Questions
Q: What is the weight and physical size of the 6ES7441-1AA03-0AE0?
A: Approximately 720 g, with dimensions of 25 mm width, 290 mm height, and 210 mm depth. The interface module weighs approximately 100 g.
Q: What interface physics does the CP 441-1 support?
A: Interchangeable interface modules for 20 mA (TTY), RS 232C (V.24), and RS 422/485 (X.27).
Q: What is the maximum cable length for each interface type?
A: 1000 m for TTY, 10 m for RS 232, and 1200 m for RS 422/485, all with shielded cable.
Field Installation Guidelines
Insert the module into the S7-400 rack and secure the mounting screws. Install the required interface module before energizing. Verify 5 VDC and 24 VDC supply availability. Route shielded cable within the limits of the installed interface physics: 1000 m for TTY, 10 m for RS 232, and 1200 m for RS 422/485. Ground the shield at one end. Confirm the protocol and printer driver configuration in STEP 7 matches the connected device before commissioning. Verify the S7-CPU memory card has capacity for up to 55 kbyte of message texts. Install the configuration package from CD before parameter assignment.
Goşmaça spesifikasiýalar
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
Is Compact DCS Better Than PLC for Small Plants?
This article examines the ABB AC700F Freelance DCS as a compact control solution for small batch process plants ...
-
What Makes ControlEdge UCD Ideal for Water Treatment DCS?
Honeywell ControlEdge UCD DCS delivers DCS-grade reliability in a compact, PLC-like footprint suited to mid-size muni...
-
Why Is Redundant DCS Essential for 24/7 Process Automation?
ABB Freelance AC900F redundant DCS delivers hot standby CPU switching within 5 ms, hot-swappable S700 I/O, and verifi...
-
What Makes Honeywell C200 DCS Installation Standards So Critical?
This article examines Honeywell Experion PKS C200 DCS installation standards, key technical parameters, CPU and I/O f...
-
How Can You Avoid Hidden Faults in Logix5000 PLC Migration?
Allen-Bradley Logix5000 migration involves far more than a firmware flash. Version jumps from V20 to V30 can add 0.4 ...
-
How Do Thermal Stress and Aging Affect Ovation I/O Module Life?
This article explains how thermal stress, vibration and capacitor aging degrade Emerson Ovation I/O modules in power ...