Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:6ES7422-5EH10-0AB0
Siemens 6ES7422-5EH10-0AB0 | SM 422 DO 16 Module
Manufacturer: Siemens
Product No.: 6ES7422-5EH10-0AB0
Product Type: Digital Output Module
Product Origin: DE
Payment:T/T, Western Union
Weight: 1020g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
Product Overview
The Siemens 6ES7422-5EH10-0AB0 is an SM 422 digital output module for the SIMATIC S7-400 automation system. It provides 16 isolated outputs rated for DC 20-125 V with 1.5 A output current. Weighing approximately 1.02 kg, this module delivers reliable actuator control with integrated diagnostics and electronic short-circuit protection for demanding industrial applications.
Technical Configuration
This module offers 16 outputs arranged in two groups of 8. Output voltage for signal "1" is minimum L+ (-1.0 V) with a permitted current range of 10 mA to 1.5 A and peak current up to 3 A for 10 ms. Output delay is maximum 2 ms from "0" to "1" and maximum 13 ms from "1" to "0" for resistive loads. Parallel connection of two outputs supports redundant load control and performance enhancement within the same group.
Technical Specifications
| Parameter | Value |
|---|---|
| Manufacturer | Siemens |
| Part Number | 6ES7422-5EH10-0AB0 |
| Product Type | SM 422 Digital Output Module |
| Series | SIMATIC S7-400 |
| Number of Outputs | 16, isolated in 2 groups of 8 |
| Output Voltage Range | DC 20-125 V |
| Output Current (Rated) | 1.5 A |
| Output Current Range | 10 mA to 1.5 A |
| Peak Current | Max 3 A for 10 ms |
| Residual Current (Signal 0) | Max 0.5 mA |
| Output Delay (0 to 1) | Max 2 ms (resistive load) |
| Output Delay (1 to 0) | Max 13 ms (resistive load) |
| Switching Frequency (Resistive) | Max 10 Hz |
| Switching Frequency (Inductive) | Max 0.5 Hz (IEC 947-5-1, DC 13) |
| Short-Circuit Protection | Electronic, threshold typically 4 to 5 A |
| Replacement Fuse | 8 A / 250 V, fast-acting |
| Parallel Outputs | Supported (same group only) |
| Weight | Approx. 1.02 kg |
Installation Guide
Install the SM 422 module in a compatible S7-400 rack slot and secure the front connector. Before replacing the fuse, always unplug the front connector to prevent electric shock hazard. Distribute high-current loads between the two output groups for optimal performance. To reset a disconnected output after a short circuit, first set the output signal to 0, then back to 1. Mechanical power contact may produce voltage pulses lasting up to 0.5 ms at the outputs.
Engineering Advantages
This module provides 16 isolated outputs in two groups, enabling flexible actuator control with group-level isolation. Electronic short-circuit protection with a 4-5 A threshold safeguards connected equipment. The wide DC 20-125 V output range accommodates diverse actuator types without additional interface components. Integrated diagnostics support proactive maintenance and rapid fault identification. Parallel output capability within the same group enables redundant load control for critical applications.
Technical FAQs
Q1: What is the output current rating of the 6ES7422-5EH10-0AB0?
A1: This module provides 1.5 A rated output current per channel, with a permitted range of 10 mA to 1.5 A and peak current up to 3 A for 10 ms.
Q2: Can two outputs be paralleled for higher current?
A2: Yes, parallel connection of two outputs is supported for redundant load control and performance enhancement, but only within the same output group.
Q3: What fuse type does this module require?
A3: The module uses an 8 A / 250 V fast-acting replacement fuse. Always unplug the front connector before replacing the fuse.
Goşmaça spesifikasiýalar
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
How Can You Avoid Hidden Faults in Logix5000 PLC Migration?
Allen-Bradley Logix5000 migration involves far more than a firmware flash. Version jumps from V20 to V30 can add 0.4 ...
-
How Do Thermal Stress and Aging Affect Ovation I/O Module Life?
This article explains how thermal stress, vibration and capacitor aging degrade Emerson Ovation I/O modules in power ...
-
How Does ABB AC500-eCo Cut Machining Automation Costs?
This article explains how the ABB AC500-eCo compact PLC fits discrete machining automation, covering CPU memory ...
-
What Makes GE VersaMax Micro PLC Ideal for Factory Retrofits?
This article reviews the GE VersaMax Micro PLC as a practical retrofit solution for compact factory automation, cover...
-
Is DeltaV S-Series DCS Right for Fine Chemical Skids?
This article reviews the Emerson DeltaV S-Series DCS as a compact control solution for modular fine chemical skids, c...
-
How Does GE RX3i PACSystem Redundancy Improve Oil & Gas Skid Control?
This article explores GE RX3i PACSystem redundant control architecture for oil and gas skid automation. It cover...
