Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:TSXDSY16S5
Schneider TSXDSY16S5 Modicon Discrete Output Module
Manufacturer: Schneider
Product No.: TSXDSY16S5
Product Type: Discrete Output Module
Product Origin: FR
Payment:T/T, Western Union
Weight: 310g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
Schneider Electric TSXDSY16S5 Modicon Discrete Output Module
Schneider Electric TSXDSY16S5 | Discrete output module for the Modicon Premium and TSX Micro automation platforms. Provides 16 triac-protected outputs operating within 48-240V AC range. Integrated fast-blow fuses deliver short-circuit and overload protection at 5 A. Screw terminal block connection. Weight: 0.31 kg (0.68 lb).
Key Features
16 triac-protected discrete outputs. Output voltage 48-240V AC (EN/IEC 61131-2), 41-264V range. 1 A current per channel. 12 A maximum current per module. Response time under 10 ms activation and deactivation. Ge-Mov output overvoltage protection. 5 A integrated fast-blow fuse for overload and short-circuit protection. Isolation resistance over 10 MOhm at 500 V. Dielectric strength 2000 V at 50/60 Hz for 60 s. CE marked.
Technical Specifications
| Manufacturer | Schneider Electric |
| Part Number | TSXDSY16S5 |
| Product Line | TSX Micro PLCs / Modicon Premium |
| Product Type | Discrete Output Module |
| Discrete Output Number | 16 |
| Discrete Output Type | Triac protected |
| Discrete Output Voltage | 48-240V AC (EN/IEC 61131-2); 41-264V range |
| Current per Channel | ≤ 1 A |
| Maximum Current per Module | ≤ 12 A |
| Response Time (Activation) | < 10 ms |
| Response Time (Deactivation) | < 10 ms |
| Overvoltage Protection | Ge-Mov |
| Overload Protection | 5 A integrated fuse, fast blow |
| Short-Circuit Protection | 5 A integrated fuse, fast blow |
| Isolation Resistance | > 10 MOhm at 500 V |
| Dielectric Strength | 2000 V, 50/60 Hz, 60 s |
| Current Consumption | 220 mA @ 5V DC |
| Power Dissipation | 0.85 W + (1 W x No. of outputs x current per module) |
| Electrical Connection | Screw terminal block |
| Module Format | Standard |
| Net Weight | 0.31 kg (0.68 lb) |
| IP Degree of Protection | IP20 |
| Pollution Degree | 2 |
| Operating Temperature | 0°C to +60°C (32°F to 140°F) |
| Storage Temperature | -25°C to +70°C (-13°F to 158°F) |
| Relative Humidity | 10-95% (operation); 5-95% (storage), non-condensing |
| Operating Altitude | 0-2000 m (0-6561 ft) |
| Protective Treatment | TC |
| Standards | IEC 61131-2, UL 508, CSA C22.2, 73/23/EEC, 89/336/EEC, 93/68/EEC |
| Product Certifications | CE, ABS, RMRS, LR, GL, BV, DNV, RINA |
| Country of Origin | France |
Installation Notes
Mount in Modicon Premium or TSX Micro PLC rack. Connect field wiring via screw terminal block. Verify supply voltage remains within 48-240V AC range. Observe current limits of 1 A per channel and 12 A per module. The integrated 5 A fast-blow fuse protects against overload and short circuits. Maintain IP20 enclosure and pollution degree 2 environment. Ensure operating temperature remains between 0°C and 60°C.
Engineering Advantages
Triac-protected outputs handle AC loads directly without external relays or contactors. Integrated fast-blow fuses protect each output group against short-circuit and overload conditions. Ge-Mov overvoltage protection extends module life in electrically noisy environments. High 10 MOhm isolation resistance and 2000 V dielectric strength ensure reliable operation. Marine certifications (GL, ABS, RINA, DNV, LR, BV, RMRS) enable use in shipboard and offshore applications. Compact 0.31 kg design saves panel space.
FAQs
Q1: How many outputs does this module provide?
A1: 16 triac-protected discrete outputs.
Q2: What is the current rating per channel and per module?
A2: 1 A per channel, with 12 A maximum per module.
Q3: What protection features are integrated?
A3: Ge-Mov overvoltage protection plus a 5 A fast-blow fuse for overload and short-circuit protection.
Goşmaça spesifikasiýalar
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
Can You Restore a DCS Controller Without Downtime?
This article explains field-proven backup and recovery workflows for ABB AC800M DCS controllers. It covers pre-backup...
-
What Makes Live Honeywell Transmitter Replacement Safe?
This article explains how industrial automation teams can replace aging Honeywell transmitters online without a full ...
-
How Does Honeywell APC Improve Refinery Yield?
Honeywell APC applies model predictive control to refinery and chemical units, reducing process variability by 30% to...
-
How Can Bently Nevada Vibration Trends Predict Machine Failures?
This article explains how maintenance teams convert raw Bently Nevada TSI vibration trends into actionable predictive...
-
How Does ABB Redundant Control Cut Downtime?
ABB redundant controller architecture removes single point of failure risk in DCS and PLC systems through hot standby...
-
How Does Honeywell Universal Transmitter Improve DCS Gas Safety?
This article examines field integration practices for Honeywell Universal Transmitters within DCS architectures at ch...
