Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:TSXCTY2C
Schneider TSXCTY2C Modicon Counter Module 2 Channel
Manufacturer: Schneider
Product No.: TSXCTY2C
Product Type: Counter Module
Product Origin: FR
Payment:T/T, Western Union
Weight: 340g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
Schneider Electric TSXCTY2C Modicon Counter Module
Schneider Electric TSXCTY2C | Measurement and counter module for the Modicon Premium and TSX Micro automation platforms. Provides 2 counter channels supporting incremental encoders, absolute encoders, and 2/3-wire proximity sensors. Counting frequency up to 1 MHz. Current sink auxiliary inputs for preset, enable, and read functions. Weight: 0.34 kg (0.75 lb).
Key Features
2 counter channels. Counting frequency up to 1 MHz. Incremental encoder frequency 500 kHz (x1) and 250 kHz (x4). 1 ms cycle time. Current sink auxiliary inputs (preset, enable, read). Compatible with 2/3-wire PNP/NPN proximity sensors, incremental encoders (10-30V totem pole, 5V DC RS422), SSI absolute encoders, and ABE7CPA11 parallel absolute encoders. 24V DC output with 0.5 A nominal current. Thermal overload and short-circuit protection. Zener diode overvoltage protection. Reverse polarity protection.
Technical Specifications
| Manufacturer | Schneider Electric |
| Part Number | TSXCTY2C |
| Product Line | TSX Micro PLCs / Modicon Premium |
| Product Type | Measurement and Counter Module |
| Number of Channels | 2 |
| Counting Frequency | 1,000,000 Hz (1 MHz) |
| Incremental Encoder Frequency (x1) | 500 kHz |
| Incremental Encoder Frequency (x4) | 250 kHz |
| Cycle Time | 1 ms |
| Input Logic | Current sink auxiliary input (preset, enable, read) |
| Input Compatibility | 2/3-wire PNP/NPN proximity sensors, incremental encoder (10-30V totem pole, 5V DC RS422), SSI absolute encoder, ABE7CPA11 |
| Input Voltage (Sensors) | 24V, 16 mA |
| Input Voltage (Auxiliary) | 24V, 8 mA |
| Input Voltage (Encoder) | 5V, 18 mA |
| Voltage State 1 (Sensors/Aux) | ≥ 11V |
| Voltage State 1 (Encoder) | ≥ 2.4V |
| Voltage State 0 (Encoder) | ≤ 1.2V |
| Voltage State 0 (Sensors/Aux) | ≤ 5V |
| Input Impedance (Encoder) | > 270 Ω at 2.4V; 400 Ω at Un |
| Input Impedance (Sensors) | 1500 Ω at Un |
| Input Impedance (Auxiliary) | 3400 Ω at Un |
| Response Time (Loss of 24V) | < 2.5 ms |
| Response Time (Return of 24V) | < 10 ms |
| Output Voltage | 24V DC (19-30V limits) |
| Nominal Output Current | 0.5 A |
| Maximum Voltage Drop | < 0.5V at state 1 |
| Maximum Leakage Current | 0.1 mA |
| Switching Time | < 0.250 ms |
| Output Protection | Thermal overload, short-circuit, Zener overvoltage, reverse polarity |
| Power Dissipation | 7-10 W |
| Current Consumption | 15 mA @ 24V DC; 850 mA @ 5V DC |
| Local Signaling | RUN (green), I/O fault (red), ERR (red), 2x CH diagnostics (green) |
| Electrical Connection | 1 HE-10 20-pin connector; 2 SUB-D 15 connectors |
| Net Weight | 0.34 kg (0.75 lb) |
| Operating Temperature | 0°C to +60°C |
| Storage Temperature | -25°C to +70°C |
| Relative Humidity | 5-95% (non-condensing) |
| Operating Altitude | ≤ 2000 m |
| Protective Treatment | TC |
| Country of Origin | France |
Installation Notes
Mount in Modicon Premium or TSX Micro PLC rack. Connect sensors and encoders via HE-10 20-pin and SUB-D 15 connectors. Verify input voltage limits for each device type: ≤5.5V for encoder, 19-30V for sensors and auxiliary inputs. Use shielded cable for encoder signals to maintain signal integrity at high counting frequencies. Maintain IP20 enclosure and pollution degree 2 environment. LED indicators aid commissioning and fault diagnosis.
Engineering Advantages
1 MHz counting frequency supports high-speed position and motion applications. Dual channels enable simultaneous measurement of two axes. Wide input compatibility covers proximity sensors, incremental encoders, and SSI absolute encoders in a single module. Integrated thermal overload, short-circuit, overvoltage, and reverse polarity protection safeguard the module. 1 ms cycle time ensures fast response for time-critical control. LED diagnostics simplify troubleshooting.
FAQs
Q1: What is the maximum counting frequency?
A1: 1 MHz, with 500 kHz (x1) and 250 kHz (x4) for incremental encoders.
Q2: What input types are supported?
A2: 2/3-wire PNP/NPN proximity sensors, incremental encoders (10-30V totem pole, 5V DC RS422), SSI absolute encoders, and ABE7CPA11 parallel absolute encoders.
Q3: What output does the module provide?
A3: 24V DC output with 0.5 A nominal current, supporting positive logic DC inputs up to 15 kΩ.
Goşmaça spesifikasiýalar
- Çal
- Kümüş
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
Can You Restore a DCS Controller Without Downtime?
This article explains field-proven backup and recovery workflows for ABB AC800M DCS controllers. It covers pre-backup...
-
What Makes Live Honeywell Transmitter Replacement Safe?
This article explains how industrial automation teams can replace aging Honeywell transmitters online without a full ...
-
How Does Honeywell APC Improve Refinery Yield?
Honeywell APC applies model predictive control to refinery and chemical units, reducing process variability by 30% to...
-
How Can Bently Nevada Vibration Trends Predict Machine Failures?
This article explains how maintenance teams convert raw Bently Nevada TSI vibration trends into actionable predictive...
-
How Does ABB Redundant Control Cut Downtime?
ABB redundant controller architecture removes single point of failure risk in DCS and PLC systems through hot standby...
-
How Does Honeywell Universal Transmitter Improve DCS Gas Safety?
This article examines field integration practices for Honeywell Universal Transmitters within DCS architectures at ch...