Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:BMXCPS4002S
Schneider BMXCPS4002S X80 Power Module 100-240V AC Safety
Manufacturer: Schneider
Product No.: BMXCPS4002S
Product Type: Power Supply
Product Origin: FR
Payment:T/T, Western Union
Weight: 510g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
BMXCPS4002S Schneider Modicon X80 Redundant Power Supply – 100-240V AC Safety
The Schneider Electric BMXCPS4002S is a redundant power supply module for the Modicon X80 range with safety certification. Accepts 100-240V AC input with 15W at 3.3V DC and 40W at 24V DC secondary output. Net weight is 0.51 kg.
Product Information
| Manufacturer | Schneider Electric |
| Range of Product | Modicon X80 |
| Part Number | BMXCPS4002S |
| Product Type | Power Supply Module (Redundant, Safety) |
| Backplane Compatibility | All Backplanes |
| Primary Voltage | 100-240V AC |
| Primary Voltage Limit | 85-264V |
| Network Frequency | 50/60 Hz (Limits 47-63 Hz) |
| Net Weight | 0.51 kg |
| Country of Origin | Indonesia |
| GTIN | 3606481204950 |
Secondary Power Output
| 3.3V DC Output | 15W (I/O Module Logic) |
| 24V DC Output | 40W (I/O Module Power and Processor) |
| Current at 3.3V DC | 4.5 A |
| Current at 24V DC | 1.67 A |
| Max Power Dissipation | 8.5W |
Input Specifications
| Apparent Power | 0.13 kVA |
| Input Current at 230V | 0.55 A |
| Input Current at 115V | 1.1 A |
| Inrush Current at 115V | 30 A |
| Inrush Current at 230V | 60 A |
| I²t on Activation | 1 A²·s at 115V, 4 A²·s at 230V |
Protection and Isolation
| Primary Protection | Internal Fuse (Not Accessible) |
| Secondary Protection | Overload, Overvoltage, Short-Circuit |
| Insulation Resistance | ≥100 MOhm Primary/Ground and Primary/Secondary |
| Dielectric Strength (Primary/Secondary) | 1500V |
| Dielectric Strength (Sensor Power) | 2300V |
| Dielectric Strength (Primary/Ground) | 1500V |
| Microbreak Immunity | 10 ms |
Environmental Specifications
| Operating Temperature | -25°C to 60°C (-13°F to 140°F) |
| Storage Temperature | -40°C to 85°C (-40°F to 185°F) |
| Relative Humidity | 5% to 95% at 55°C Non-Condensing |
| IP Protection | IP20 |
| Vibration Resistance | 3 gn |
| Shock Resistance | 15 gn |
| Operating Altitude | 0-2000 m (2000-5000 m with Derating) |
Diagnostics and Status
- Redundancy Test via Network
- Temperature Sensing
- Remaining Lifetime Monitoring
- Uptime Duration Tracking
- OK LED (Green) – Presence of Voltages
- Redundancy OK LED (Green)
- Power Supply Status LED (Green)
- RESET Push-Button for Cold Restart
Certifications and Standards
| Product Certifications | CE, UL, CSA, RCM, EAC, Merchant Navy, ATEX Zone 2/22, IECEx Zone 2/22, TÜV |
| Standards | EN/IEC 61131-2, EN/IEC 61010-2-201, UL 61010-2-201, CSA C22.2 No 61010-2-201, IACS E10, EN/IEC 61000-6-5, EN/IEC 61850-3, EN/IEC 60079-0 |
| Directives | 2014/30/EU EMC, 2006/42/EC Machinery, 2014/34/EU ATEX |
Features
- Redundant power supply for Modicon X80
- Safety certified with SIL 3 capability
- 100-240V AC wide input range
- Dual secondary output: 15W at 3.3V DC and 40W at 24V DC
- Advanced network diagnostics
- Conformal coating for harsh environments
- ATEX Zone 2/22 and IECEx Zone 2/22 certified
- High MTBF of 792000 hours
- Compact 0.51 kg design
Applications
- Safety-critical process control
- Redundant power systems
- Industrial automation
- Oil and gas installations
- Power generation control
FAQs
Q1: What is the input and output power rating?
A1: 100-240V AC input with 15W at 3.3V DC and 40W at 24V DC secondary output.
Q2: What diagnostics are available via network?
A2: Redundancy test, temperature sensing, remaining lifetime, and uptime duration.
Q3: What is the weight and MTBF reliability?
A3: 0.51 kg with MTBF reliability of 792000 hours.
Goşmaça spesifikasiýalar
- Göni tok bilen işleýän
- Kompakt
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
How Can You Avoid Hidden Faults in Logix5000 PLC Migration?
Allen-Bradley Logix5000 migration involves far more than a firmware flash. Version jumps from V20 to V30 can add 0.4 ...
-
How Do Thermal Stress and Aging Affect Ovation I/O Module Life?
This article explains how thermal stress, vibration and capacitor aging degrade Emerson Ovation I/O modules in power ...
-
How Does ABB AC500-eCo Cut Machining Automation Costs?
This article explains how the ABB AC500-eCo compact PLC fits discrete machining automation, covering CPU memory ...
-
What Makes GE VersaMax Micro PLC Ideal for Factory Retrofits?
This article reviews the GE VersaMax Micro PLC as a practical retrofit solution for compact factory automation, cover...
-
Is DeltaV S-Series DCS Right for Fine Chemical Skids?
This article reviews the Emerson DeltaV S-Series DCS as a compact control solution for modular fine chemical skids, c...
-
How Does GE RX3i PACSystem Redundancy Improve Oil & Gas Skid Control?
This article explores GE RX3i PACSystem redundant control architecture for oil and gas skid automation. It cover...