Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:ATV71HU30N4
Schneider ATV71HU30N4 | 3kW Variable Speed Drive Modbus
Manufacturer: Schneider
Product No.: ATV71HU30N4
Product Type: Variable Speed Drive
Product Origin: FR
Payment:T/T, Western Union
Weight: 4000g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
Schneider Electric ATV71HU30N4 Altivar 71 Variable Speed Drive
Product Overview
The Schneider Electric ATV71HU30N4 is a variable speed drive from the Altivar 71 series, designed for complex, high-power machines. It delivers 3 kW (3 HP) motor power for 3-phase 380-480 V asynchronous and synchronous motors, with an output current range of 6.2 to 7.8 A. The drive features an integrated EMC filter, heat sink assembly, and a wide output frequency range of 0.1 to 599 Hz. Weight is 4 kg (8.8 lbs).
Specifications
| Parameter | Value |
|---|---|
| Brand | Schneider Electric |
| Model | ATV71HU30N4 |
| Product Line | Altivar 71 |
| Product Type | Variable Speed Drive |
| Motor Power | 3 kW (3 HP), 3-Phase 380-480 V |
| Input Voltage | 380-480 VAC (-15% to +10%) |
| Supply Voltage Limits | 323-528 V |
| Frequency | 50/60 Hz (±5%), Limits 47.5-63 Hz |
| Line Current (480 V) | 9 A |
| Line Current (380 V) | 10.7 A |
| Nominal Output Current (380 V) | 7.8 A @ 4 kHz |
| Nominal Output Current (460 V) | 6.2 A @ 4 kHz |
| Output Current Range | 6.2-7.8 A |
| Max Transient Current | 11.7 A (60 s) / 12.9 A (2 s) |
| Output Frequency | 0.1-599 Hz |
| Nominal Switching Frequency | 4 kHz |
| Switching Frequency Range | 1-16 kHz (4-16 kHz with derating) |
| Apparent Power | 7 kVA at 380 V |
| Max Motor Cable Length | 50 m Shielded / 100 m Unshielded |
| EMC Filter | Integrated |
| Assembly Style | With Heat Sink |
| Output Voltage | 0-380/480 V (3-Phase) |
| Dimensions (W x H x D) | 155 x 260 x 187 mm |
| Weight | 4 kg (8.8 lbs) |
| UPC | 785901602866 |
Additional Technical Parameters
| Parameter | Value |
|---|---|
| Speed Range (Open-Loop) | 1-100 Asynchronous Motor |
| Speed Range (Closed-Loop) | 1-1000 Asynchronous Motor with Encoder |
| Speed Accuracy (Closed-Loop) | ±0.01% of Nominal Speed |
| Torque Accuracy (Closed-Loop) | ±5% |
| Transient Overtorque | 170% (60 s) / 220% (2 s) |
| Braking Torque (with Resistor) | ≤150% |
| Braking Torque (without Resistor) | 30% |
| Acceleration/Deceleration Ramps | 0.01-9000 s (Linear, S, U, Customized) |
| Analogue Inputs | 2 (AI1 ±10 VDC, AI2 0-20 mA / 0-10 VDC) |
| Analogue Output | 1 (AO1 0-20 mA / 0-10 VDC) |
| Discrete Inputs | 7 (LI1-LI5 24 VDC, LI6 Switchable PTC) |
| Discrete Outputs | 2 Relay (R1 NO/NC, R2 NO) |
| Relay Switching Current | 5 A (250 VAC / 30 VDC Resistive) |
| Communication Protocols | Modbus, CANopen |
| Dielectric Strength (Power/Earth) | 3535 VDC |
| Dielectric Strength (Control/Power) | 5092 VDC |
| Operating Temperature | -10 to +50 °C (Without Derating) |
| Storage Temperature | -25 to +70 °C |
| Protection Rating | IP20 |
| Operating Altitude (No Derating) | ≤1000 m |
FAQs
Q1: What motor power rating does the ATV71HU30N4 provide?
A1: 3 kW (3 HP) for 3-phase 380-480 V asynchronous and synchronous motors.
Q2: What is the output current range of this drive?
A2: 6.2 to 7.8 A, with nominal output current of 7.8 A at 380 V and 6.2 A at 460 V.
Q3: Does this drive include an EMC filter?
A3: Yes. The ATV71HU30N4 features an integrated EMC filter, reducing the need for external filtering components.
Goşmaça spesifikasiýalar
- Göni tok bilen işleýän
- Kompakt
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
How Do MTL Intrinsic Safety Barriers Protect Petrochemical DCS Loops?
This article explains how industrial automation teams size MTL intrinsic safety barriers for petrochemical DCS a...
-
How Does Bently 3500 TSI Detect Proximity Probe Faults?
This article explains Bently 3500 TSI proximity probe troubleshooting, technical parameters and calibrated insta...
-
How to Diagnose Yokogawa CENTUM VP FCS Redundancy Faults?
This article explains how industrial automation teams can diagnose and debug Yokogawa CENTUM VP FCS controller redund...
-
How Does Siemens S7-1500 PLC Handle PROFINET Real-Time Jitter?
This article examines measurable PROFINET fault modes on Siemens S7-1500 PLC controllers and provides field-prov...
-
Why Do ABB AC800M Redundancy Mismatch Faults Keep Returning?
ABB AC800M redundancy mismatch faults account for 42.7 percent of controller alarms in 800xA systems. Most stem ...
-
How Does Honeywell C300 Improve on C200 DCS Controllers?
Honeywell C300 controllers deliver major gains over C200 in memory, scan speed, redundancy switching, and reliability...