Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:1734-IR2
RTD / Resistance Input | 2 Channel 1734-IR2 Allen-Bradley
Manufacturer: Allen-Bradley
Product No.: 1734-IR2
Product Type: Input RTD Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 36g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
Product Overview
The Allen-Bradley 1734-IR2 is a POINT I/O RTD and resistance input module with 2 single-ended, non-isolated channels. It supports Pt, Cu, and Ni RTD sensors plus direct 0-600 Ω analog signal wiring with 16-bit resolution. Weighing 0.08 pounds (0.036 kg), this open-style module uses Delta Sigma conversion and delivers 0.1% full-scale accuracy at 25°C for precise temperature measurement.
Technical Specifications
| Parameter | Value |
|---|---|
| Manufacturer | Rockwell Automation |
| Brand | Allen-Bradley |
| Part Number | 1734-IR2 |
| Series | POINT I/O |
| Module Type | RTD / Resistance Input Module |
| Inputs | 2 single-ended, non-isolated |
| Compatible RTD Sensors | 100/200 Pt α=0.00385 and 0.003916; 10 Cu α=0.00427; 100/120 Ni α=0.00618; 120 Ni α=0.00672 |
| Resistance Input | 0-600 Ω |
| Resolution | 16 bits; 9.5 mΩ/cnt; 0.03°C/cnt or 0.05°F/cnt |
| Absolute Accuracy | 0.1% full scale at 25°C |
| Step Response (50 Hz notch) | 60 ms per channel |
| Step Response (60 Hz notch) | 50 ms per channel |
| Update Rate (60 Hz default) | 33 ms per module |
| Current Draw | 220 mA at 5V DC |
| Power Dissipation | 1.0 W at 28.8V DC |
| Thermal Dissipation | 3.3 BTU/hour |
| Isolation Voltage | 50V continuous |
| Conversion Type | Delta Sigma |
| Data Format | Signed integer |
| Keyswitch Position | 6 |
| Wiring Base Assemblies | 1734-TB, 1734-TBS, 1734-TOP, 1734-TOPS |
| Dimensions (H x W x D) | 2.21 x 0.47 x 2.97 in (56 x 12 x 75.5 mm) |
| Weight | 0.08 lbs (0.036 kg) |
| Operating Temperature | -20 to 55°C |
| Enclosure | Open style |
Installation Guide
Rotate the wiring base keyswitch to position 6 before installing the module. Mount on 1734-TB, 1734-TBS, 1734-TOP, or 1734-TOPS wiring base assemblies. Wire RTD sensors or 0-600 Ω resistance signals according to the selected sensor type. Select the appropriate notch filter frequency to balance response time against noise rejection for your application. Verify the 220 mA current draw at 5V DC is within POINT bus capacity before power-up.
Engineering Advantages
This module supports eight RTD sensor types plus direct 0-600 Ω resistance input, providing exceptional flexibility for temperature and position measurement. The 16-bit resolution at 9.5 mΩ/count enables precise low-resistance detection. Selectable notch filters from 50 to 480 Hz optimize response time versus noise immunity for specific plant environments. Delta Sigma conversion delivers stable readings with 0.1% full-scale accuracy. The compact 0.036 kg open-style design conserves panel space.
Technical FAQs
Q1: What sensor types does the 1734-IR2 support?
A1: This module supports 100/200 Pt α=0.00385 and 0.003916, 10 Cu α=0.00427, 100/120 Ni α=0.00618, and 120 Ni α=0.00672 RTD sensors plus direct 0-600 Ω resistance input.
Q2: What is the resolution and accuracy of this module?
A2: The 1734-IR2 provides 16-bit resolution at 9.5 mΩ/count with 0.1% full-scale absolute accuracy at 25°C.
Q3: How does the notch filter affect response time?
A3: Step response ranges from 60 ms at 50 Hz notch to 6 ms at 480 Hz notch, while module update rate ranges from 40 ms to 4 ms respectively.
Goşmaça spesifikasiýalar
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
When Should You Replace a Yokogawa Analog IO Card?
This article breaks down Yokogawa analog AI/AO card calibration tolerances, drift aging benchmarks, and formal replac...
-
What Performance Gains Does S7-1500 Offer Over Legacy S7 PLCs?
Legacy Siemens S7-300 and S7-400 PLCs face spare-part shortages, rising failure rates and limited network capability,...
-
What Logic Changes Cut SIS False Trips by 94%?
This article examines practical logic modification and parameter tuning methods for ABB 800xA HI SIL3 safety ins...
-
Why Do FTE Redundancy Failovers Lock Up in DCS?
Honeywell FTE delivers sub-500 ms failover for Experion PKS, yet field records show 38% of outages stem from installa...
-
How Does the Bently Nevada 3500/42M Vibration Module Drift?
This technical guide examines the Bently Nevada 3500/42M vibration module within industrial automation architect...
-
What Causes IC694MDL Fault Codes in GE RX3i PLC Systems?
This guide explains GE RX3i IC694MDL discrete I/O fault codes, key electrical parameters, ESD and torque requirements...