Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:V18345-1017121001
Positioner | Original Stock ABB V18345-1017121001 TZIDC
Manufacturer: ABB
Product No.: V18345-1017121001
Product Type: Valve Positioner Module
Product Origin: Sweden
Payment:T/T, Western Union
Weight: 1700g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
ABB V18345-1017121001 TZIDC Electro-Pneumatic Positioner
The V18345-1017121001 (also cataloged as the V18345 Electro-Pneumatic Positioner) is a TZIDC intelligent positioner in a varnished aluminium case rated IP 65 (NEMA 4X). It accepts a 4-20 mA two-wire input and provides single-acting fail-safe, fail-freeze output, with ATEX Ex II 2 G EEx ia II C T6 explosion protection. Unit weight is 1.7 kg.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | V18345-1017121001 |
| Brand | ABB |
| Product Type | TZIDC Electro-Pneumatic Positioner |
| Housing | Aluminium, IP 65 / NEMA 4X, RAL 9005 matte black |
| Weight | 1.7 kg |
| Input Signal | 4 to 20 mA, two-wire |
| Explosion Protection | ATEX Ex II 2 G EEx ia II C T6 |
| Output Function | Single acting, fail safe, fail freeze |
| Supply Pressure | 1.4 to 6 bar (20 to 90 psi) |
| Air Consumption | < 0.03 kg/h / 0.015 scfm |
| Pneumatic Connections | Threads G 1/4 or 1/4-18 NPT |
| Electrical Connections | Cable: Thread 1/2-14 NPT |
| Digital Input | 0-5 V DC logical 0; 11-30 V DC logical 1 |
| Digital Output | 5 to 11 V DC, DIN 19234/NAMUR |
| Position Feedback | Mechanical kit with proximity switches SJ2-SN (NC or logical 1) |
Electropneumatic Control and Explosion Protection
The V18345-1017121001 uses two-wire technology with a nominal 4-20 mA output signal. The digital input switches at 0-5 V DC for logical 0 and 11-30 V DC for logical 1. The digital output follows the DIN 19234/NAMUR control circuit at 5-11 V DC supply. Supply pressure spans 1.4 to 6 bar (20 to 90 psi), with air consumption below 0.03 kg/h (0.015 scfm) independent of supply pressure. The ATEX Ex II 2 G EEx ia II C T6 certification permits installation in Zone 1 hazardous gas atmospheres with intrinsically safe input circuits. The case is electrostatically dipped and stove-hardened with epoxy resin; the case is varnished RAL 9005 matte black and the housing cover is Pantone 420. The optional mechanical feedback kit uses SJ2-SN proximity switches configured as NC or logical 1.
Field Installation Guidelines
Mount the positioner to a linear actuator per DIN/IEC 534 / NAMUR or to a rotary actuator per VDI/VDE 3845. Verify the hazardous area classification matches ATEX Ex II 2 G EEx ia II C T6 and confirm the input loop is intrinsically safe before wiring. Confirm the 1.7 kg unit is supported by the actuator mounting bracket. Connect the 4-20 mA input through the 1/2-14 NPT cable entry and the air supply through the G 1/4 or 1/4-18 NPT port. Verify supply air is dry and oil-free within 1.4 to 6 bar. Route signal wiring separately from AC power conductors and maintain the varnished case seal for IP 65 / NEMA 4X integrity. Set the fail-safe, fail-freeze action and proximity switch logic before placing the loop in service.
Frequently Asked Questions
Q: What is the explosion protection rating of the V18345-1017121001?
A: ATEX Ex II 2 G EEx ia II C T6.
Q: What is the supply pressure range and air consumption?
A: 1.4 to 6 bar (20 to 90 psi); air consumption below 0.03 kg/h (0.015 scfm).
Q: What is the unit weight?
A: 1.7 kg.
Goşmaça spesifikasiýalar
- Kümüş
- Ak
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
How Does the Bently Nevada 3500/42M Vibration Module Drift?
This technical guide examines the Bently Nevada 3500/42M vibration module within industrial automation architect...
-
What Causes IC694MDL Fault Codes in GE RX3i PLC Systems?
This guide explains GE RX3i IC694MDL discrete I/O fault codes, key electrical parameters, ESD and torque requirements...
-
What CFC Rules Cut PCS7 Batch Abort Rates Fast?
This article presents enforceable CFC programming governance rules for Siemens PCS7 DCS batch plants, covering b...
-
What Makes the 1769-L3ER Ideal for Compact Skid Automation?
This guide explains how the Allen-Bradley 1769 CompactLogix L3ER bridges the gap between micro PLCs and large DC...
-
Why Do SIL3 Safety Interlocks Still Trip in Industrial Plants?
This article reviews Honeywell Safety Manager SIL3 SIS architecture, wiring and cabinet installation rules, PFDa...
-
How Does Poor Grounding Cause 4-20mA Signal Drift?
This guide explains how MTL signal isolators fail through distortion, drift and EMI in PLC and DCS loops, then d...