Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:MTL5049
MTL5049 Dual Channel Signal Isolator - MTL Instruments
Manufacturer: MTL
Product No.: MTL5049
Product Type: Repeater Power Supply
Product Origin: USA
Payment:T/T, Western Union
Weight: 110g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
MTL5049 Dual Channel Signal Isolator
The MTL5049 from MTL Instruments provides safe signal isolation for hazardous area applications. This dual-channel unit passes two 4-20mA signals from safe-area controllers to loads in explosive atmospheres. It delivers precise signal transfer with complete electrical isolation between areas.
Key Technical Specifications
- Brand: MTL Instruments
- Model: MTL5049
- Product Type: Dual Channel Signal Isolator
- Channels: Two independent channels
- Signal Range: 4 to 20mA standard
- Extended Range: 0 to 24mA capability
- Response Time: 250µs to 10% of final value
- Supply Voltage: 20 to 35V DC
Hazardous Area Certification
- Load Location: Zone 0, IIC, T4-T6 hazardous area
- Division Rating: Division 1, Group A hazardous location
- The MTL5049 maintains intrinsic safety standards
- It provides safe signal transmission to explosive atmospheres
Input Specifications
- Signal Range: 4 to 20mA from controllers
- Extended Range: 0 to 24mA under/over range
- Input Voltage Drop: <4V at 20mA
- Channel 1 Input: Terminal 11 (Input –ve), Terminal 12 (Input +ve)
- Channel 2 Input: Terminal 8 (Input –ve), Terminal 9 (Input +ve)
- Low input voltage drop minimizes impact on controller outputs
Output Performance
- Load Resistance: 550Ω maximum per channel
- Output Voltage: 11V at 20mA driving capability
- Output Resistance: >2MΩ for minimal loading
- Channel 1 Output: Terminal 1 (Output –ve), Terminal 2 (Output +ve)
- Channel 2 Output: Terminal 4 (Output –ve), Terminal 5 (Output +ve)
- Each channel independently drives hazardous area loads
Accuracy & Speed
- Transfer Accuracy: Better than 20µA at 20°C
- Temperature Drift: <1µA/°C for stable operation
- Response Time: Settles within 250µs to 10% of final value
- Circuit Ripple: <40µA peak-to-peak ensures clean signals
- High speed and accuracy maintain process control integrity
Power Requirements
- Supply Voltage: 20 to 35V DC operating range
- Current Consumption: 65mA at 24V with both channels active
- Power Dissipation: 1.4W at 24V maximum
- Supply Terminals: Terminal 13 (Supply –ve), Terminal 14 (Supply +ve)
- Status Indicator: Green LED provides clear power status
Terminal Configuration
- Channel 1: Input (Terminals 11-12), Output (Terminals 1-2)
- Channel 2: Input (Terminals 8-9), Output (Terminals 4-5)
- Power Supply: Terminals 13-14 for 20-35V DC input
- Clear terminal labeling simplifies installation and maintenance
Safety Parameters
- Safety Voltage: 28V maximum
- Internal Resistance: 300Ω
- Safety Current: 93mA maximum
- Isolation Voltage: Um = 250V rms or DC
- Complete isolation ensures safe area protection
Frequently Asked Questions
-
How many signals can the MTL5049 handle?
It isolates and passes two independent 4-20mA signals simultaneously. -
What is the maximum load capacity?
Each output channel drives loads up to 550Ω with 11V at 20mA. -
How fast does the unit respond to signal changes?
It settles within 250 microseconds to within 10% of final value. -
Is this suitable for Zone 0 hazardous areas?
Yes, it carries certification for Zone 0, IIC, T4-T6 areas and Division 1, Group A.
Goşmaça spesifikasiýalar
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
How does hierarchical control raise factory OEE from 64% to 82%?
This article explains how hierarchical cloud-edge collaborative control replaces fragmented industrial architectures....
-
DCS-niň akylly düzgünleşdirişi termik elektrik energiýasynyň deňagramsyzlygyny düzedip biler mi?
Bu makalada akylly MPC-li DCS düzgünleşdirmesiniň we bulut bazaly dolandyryşyň ýylylyk elektrik stansiýalarynda energ...
-
Can Continuous Automation Iteration Cut Factory Costs by 18-25%?
Static industrial control systems create hidden annual cost increases of 18-25%. Phased PLC and DCS program iteration...
-
Can Anti-Interference Hardware End 38% of Automation Downtime?
Field data from chemical, wind, and automotive plants proves that industrial hardware with full IEC 61000-4 EMC certi...
-
How Does Full-Lifecycle Management Optimize PLC and DCS Assets?
Traditional industrial asset management relies on manual logging and reactive troubleshooting, causing 15–20% annual ...
-
Can an Integrated Spare Chain Slash Downtime?
Unplanned equipment failures cost Chinese factories ¥636,000 per hour. Traditional cross-border spare procurement tak...