Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:140ACO02000
Modicon Quantum AO Module | Schneider Electric 140ACO02000
Manufacturer: Schneider
Product No.: 140ACO02000
Product Type: Analog Output Module
Product Origin: FR
Payment:T/T, Western Union
Weight: 457g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Schneider Electric 140ACO02000 Analog Output Module
The Schneider Electric 140ACO02000 is a precise analog output module for Modicon Quantum systems. This 4-channel module provides reliable 4-20mA current control signals for industrial actuators and process control.
Key Technical Specifications
- Brand: Schneider Electric
- Model: 140ACO02000
- Product Type: 4-Channel Analog Output Module
- Number of Outputs: 4 isolated channels
- Output Range: 4-20 mA
- Resolution: 12 bits (0-4096 counts)
- Absolute Accuracy: ±0.20% of full scale at 25°C
- Update Time: 3 ms per channel
Performance & Protection Features
- Isolation: 500V AC between output channels
- Loop Voltage: 12-30V DC external power supply
- Diagnostics: Open circuit detection for each 4-20mA output
- Operating Temperature: 0°C to 60°C (32°F to 140°F)
- Certifications: UL 508, CSA, FM Class 1 Division 2, cUL
Module Indicators & Installation
- LED indicators for bus communication (green) and external fault (red)
- 4 green LEDs show active channels, 4 red LEDs indicate channel faults
- Standard format module for Quantum PLC rack mounting
- Bus current requirement: 480 mA
- Power dissipation: 5.3 W maximum
Shipping & Packaging
- Package includes: 1 x 140ACO02000 module
- Package dimensions: 12.40" x 6.50" x 1.89" (31.5 x 16.5 x 4.8 cm)
- Shipping weight: 16.1 oz (457 g)
- Shipping options: FedEx, UPS, DHL
Frequently Asked Questions
- What signals does this module output? It provides standard 4-20 mA current output signals.
- How many output channels are available? The module provides 4 isolated output channels.
- What is the output resolution? It features 12-bit resolution for precise control.
Additional Specifications
- Gray
- Black
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Can DCS Intelligent Regulation Fix Thermal Power Energy Imbalance?
This article explains how intelligent DCS regulation with MPC and cloud-based control solves energy-production imbala...
-
Can Continuous Automation Iteration Cut Factory Costs by 18-25%?
Static industrial control systems create hidden annual cost increases of 18-25%. Phased PLC and DCS program iteration...
-
Can Anti-Interference Hardware End 38% of Automation Downtime?
Field data from chemical, wind, and automotive plants proves that industrial hardware with full IEC 61000-4 EMC certi...
-
How Does Full-Lifecycle Management Optimize PLC and DCS Assets?
Traditional industrial asset management relies on manual logging and reactive troubleshooting, causing 15–20% annual ...
-
Can an Integrated Spare Chain Slash Downtime?
Unplanned equipment failures cost Chinese factories ¥636,000 per hour. Traditional cross-border spare procurement tak...
-
Why Do 30% of Automation Upgrades Fail Due to Integration Gaps?
This technical article explains how digital-intelligent fusion overcomes fragmented workshop operations using industr...