Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:E1060
Mitsubishi E1060 Operator Interface Unit MELSEC Automation Systems
Manufacturer: Mitsubishi
Product No.: E1060
Product Type: Operator Interface
Product Origin: JP
Payment:T/T, Western Union
Weight: 1110g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
Mitsubishi E1060 Operator Terminal
The Mitsubishi E1060 is a durable operator terminal for industrial automation. It provides a reliable human-machine interface (HMI) for machine control. This terminal includes an integrated keypad for direct operator input. It is designed for easy panel mounting in control cabinets. The housing uses robust powder-coated aluminum. The E1060 connects via Ethernet and serial ports for versatile communication.
Key Features
- Integrated Keypad: Allows direct parameter entry and control functions.
- Dual Communication Ports: Features Ethernet (10/100Base-T) and RS422/485 serial for flexible connectivity.
- Rugged Metal Housing: Powder-coated aluminum ensures durability in harsh environments.
- Panel-Mount Design: Simplified installation into standard panel cutouts.
- Low Power Operation: Efficient 24V DC power consumption reduces energy load.
Technical Specifications
- Manufacturer: Mitsubishi Electric
- Model: E1060
- Product Type: Operator Terminal / Graphic Operation Terminal (GOT)
- Product Status: Limited (Please verify current availability)
- Display: Monochrome or color STN LCD (model specific)
- Keypad: Yes, tactile membrane keypad
- Housing Material: Powder-coated aluminum, grey
- Overall Dimensions (HxWxD): 275 mm x 168 mm x 63.3 mm
- Panel Cut-out Dimensions: 240 mm x 130 mm
- Weight: 1.11 kg
- Supply Voltage: 20 - 30 V DC
- Rated Current: 0.3 A @ 24V DC
- Maximum Current: 0.5 A
- Input Protection: Internal 2.0 A time-lag fuse
- Ethernet Interface: 1 port, 10/100 Base-TX (RJ45, shielded)
- Serial Interface: 1 port, RS-422 / RS-485 (configurable)
- Operating Temperature: 0°C to +50°C
- Storage Temperature: -20°C to +60°C
- Relative Humidity: 10% to 90% (non-condensing)
- Front Panel Protection: IP65 (when properly gasketed and mounted)
- Compatible Controllers: Mitsubishi MELSEC FX, Q, L series PLCs
Installation and Configuration
- Prepare the panel with a 240mm x 130mm cutout.
- Insert the terminal from the front and secure it with the mounting clamps.
- Connect a 24V DC power supply to the correct terminals, observing polarity.
- Attach the Ethernet cable to network with the PLC or programming computer.
- Use the serial port for direct connection to a PLC or other serial devices.
- Configure screen data and communication settings using Mitsubishi's GT Designer software.
Typical Applications
- Local operator interface for factory automation machines.
- Status monitoring and control for Mitsubishi PLC-based systems.
- Parameter setting and recipe management on production lines.
- Basic data display and alarm indication in industrial equipment.
Frequently Asked Questions (FAQ)
Q: What software is used to create screens for the E1060?
- A: You use Mitsubishi's GT Designer or GT Works software to design the HMI screens and configure communication settings.
Q: Can the E1060 connect to non-Mitsubishi PLCs?
- A: Primarily designed for Mitsubishi PLCs. Connection to other brands may be possible through the serial port using generic protocols like Modbus RTU, but functionality may be limited.
Q: What does the "Limited" product status imply?
- A: It suggests this model may be nearing the end of its production lifecycle. For new projects, consider consulting Mitsubishi for recommended successor models like the GT series.
Goşmaça spesifikasiýalar
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
Can Standardized Engineering Cut Factory Upgrade Costs by 40%?
This article presents a data‑driven alternative to full control system replacements in brown‑field plants. Allen‑Brad...
-
Choosing the Right Gas Detector for Chemical Safety?
This article examines the operational and financial impact of unreliable gas-sensing hardware in chemical process pla...
-
Is Mixed-Plant Data Fragmentation Costing You More?
Hybrid manufacturing facilities often lose nearly one-third of production data across disjointed PLC and DCS systems,...
-
Can Transient Monitoring Prevent Rotating Machinery Failures?
This technical article examines the critical role of transient data capture in rotating machinery protection, highlig...
-
Can Smart Gas Monitoring Cut False Alarms in Oil Facilities?
This article examines gas detection challenges in extreme oil and gas environments where legacy sensors show high dri...
-
Fixed Gas Detector or Transmitter – Which Protects Your Plant Better?
This technical article examines the critical operational differences between fixed gas detectors and gas detection tr...