Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:V18345-1010251001
Intelligent Positioner IP65 | ABB TZIDC-120 V18345-1010251001
Manufacturer: ABB
Product No.: V18345-1010251001
Product Type: Valve Positioner Module
Product Origin: Sweden
Payment:T/T, Western Union
Weight: 1700g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
ABB V18345-1010251001 TZIDC-120 Intelligent Positioner
Product Overview
ABB V18345-1010251001 is a TZIDC-120 intelligent positioner with configurable indicator and operator panel. Features varnished aluminum case IP65 (NEMA 4X) for mounting to linear actuators per DIN/IEC 534/NAMUR or rotary actuators per VDI/VDE 3845. Accepts 4-20mA two-wire input with LKS adapter connector plug. Single acting fail freeze action. Cable connection M20x1.5 and air pipe 1/4-18 NPT. Includes plug-in analog position feedback module 4-20mA.
Model Number Decoder
| Position | Code | Meaning |
|---|---|---|
| Base | V18345 | TZIDC-120 Intelligent Positioner |
| Case/Mounting | 2 | Varnished aluminum IP65, DIN/IEC 534/NAMUR or VDI/VDE 3845 |
| Input/Communication | 1 | 4-20mA two-wire with LKS adapter connector |
| Explosion Protection | 0 | Without |
| Output/Safe Position | 2 | Single acting, fail freeze |
| Connections | 5 | Cable M20x1.5, Air 1/4-18 NPT |
| Option Modules | 1 | Plug-in analog position feedback 4-20mA |
| Mech Feedback | 0 | Without |
| Design | 1 | Standard |
Technical Specifications
| Parameter | Value |
|---|---|
| Brand | ABB |
| Model | V18345-1010251001 |
| Type | TZIDC-120 Intelligent Positioner |
| Action | Single Acting, Fail Freeze |
| Signal Range | 4 to 20 mA two-wire |
| Supply Pressure | 1.4 to 6 bar (20 to 90 psi) |
| Air Consumption | < 0.03 kg/h (0.015 scfm) |
| Action Signal | Direct 4-20mA = 0-100%, Reverse 20-4mA = 0-100% |
| Characteristic Curve | Linear, equal percentage 1:25/1:50/25:1/50:1, 20 points |
| Characteristic Deviation | ≤ 0.5% |
| Tolerance Band | 0.3 to 10% adjustable |
| Dead Band | 0.1 to 10% adjustable |
| Resolution A/D | > 4000 steps |
| Sample Rate | 20 ms |
| Temp Influence | ≤ 0.5% per 10°C |
| Vibration Influence | ≤ ±1% up to 10g and 80Hz |
| Seismic | DIN/IEC 68-3-3 Class III |
| Mounting Orientation | No effect |
| Electrical Connection | M20x1.5 |
| Pneumatic Connection | 1/4-18 NPT |
| Protection Class | IP65, NEMA 4X |
| Weight | 1.7 kg (3.75 lbs) |
Installation
Mount on linear actuators per DIN/IEC 534/NAMUR or rotary actuators per VDI/VDE 3845. Ready for integral mounting. Connect 4-20mA two-wire input with LKS adapter. Wire electrical connection at M20x1.5. Connect air supply at 1/4-18 NPT with 1.4 to 6 bar pressure. Do not exceed maximum operating pressure of the actuator. Configure characteristic curve via 20 reference points. Verify IP65 seal after installation.
Features
TZIDC-120 intelligent positioner with configurable indicator and operator panel. Single acting fail freeze action. 4-20mA two-wire input with LKS adapter. Plug-in analog position feedback 4-20mA. Characteristic deviation ≤0.5%. Resolution >4000 steps. Sample rate 20 ms. Air consumption less than 0.03 kg/h independent of supply pressure. Seismic rated per DIN/IEC 68-3-3 Class III. No effect from mounting orientation. Aluminum case with epoxy resin varnish IP65 NEMA 4X. Weight 1.7 kg.
FAQ
Q1: What is the action type and fail position?
A1: Single acting with fail freeze action. In case of electrical failure, the actuator is blocked or air is vented depending on configuration.
Q2: What is the air consumption and supply pressure?
A2: Air consumption less than 0.03 kg/h independent of supply pressure. Supply pressure range 1.4 to 6 bar (20 to 90 psi).
Q3: What is the characteristic deviation and resolution?
A3: Characteristic deviation ≤0.5%. Resolution >4000 steps. Sample rate 20 ms. Tolerance band adjustable 0.3 to 10%. Weight 1.7 kg.
Goşmaça spesifikasiýalar
- Kümüş
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
What Logic Changes Cut SIS False Trips by 94%?
This article examines practical logic modification and parameter tuning methods for ABB 800xA HI SIL3 safety ins...
-
Why Do FTE Redundancy Failovers Lock Up in DCS?
Honeywell FTE delivers sub-500 ms failover for Experion PKS, yet field records show 38% of outages stem from installa...
-
How Does the Bently Nevada 3500/42M Vibration Module Drift?
This technical guide examines the Bently Nevada 3500/42M vibration module within industrial automation architect...
-
What Causes IC694MDL Fault Codes in GE RX3i PLC Systems?
This guide explains GE RX3i IC694MDL discrete I/O fault codes, key electrical parameters, ESD and torque requirements...
-
What CFC Rules Cut PCS7 Batch Abort Rates Fast?
This article presents enforceable CFC programming governance rules for Siemens PCS7 DCS batch plants, covering b...
-
What Makes the 1769-L3ER Ideal for Compact Skid Automation?
This guide explains how the Allen-Bradley 1769 CompactLogix L3ER bridges the gap between micro PLCs and large DC...