Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:IC695ALG412
IC695ALG412 General Electric RX3i Strain Gauge Module
Manufacturer: General Electric
Product No.: IC695ALG412
Product Type: Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 450g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
The General Electric IC695ALG412 is a strain gauge input module for the PACSystem RX3i platform. It features 12 individually isolated differential channels compatible with Type J, K, T, E, R, S, B, N, C thermocouples and ±150mV or ±50mV signals.
Product Details
- Part Number: IC695ALG412
- Brand: General Electric / GE Fanuc
- Series: PACSystem RX3i
- Type: Strain Gauge / Thermocouple Input Module
- Channels: 12 individually isolated differential
- Weight: Approximately 0.45 kg
Input Specifications
- Thermocouple Types: J, K, T, E, R, S, B, N, C
- Voltage Signals: ±150mV or ±50mV
- Resolution: 32-bit IEEE floating point or 16-bit integer (32-bit field)
- A/D Conversion: Sigma Delta, 15 ms @ 28 Hz to 120 ms @ 2.3 Hz
- Update Rate: 15 to 120 ms configurable
- Input Impedance: ≥500k ohm
Accuracy
- Accuracy: ±0.1% at 25°C, ±0.25% over temperature range
- Noise Rejection: 10 dB improvement
Isolation
- Channel-to-Channel: 250VAC continuous
- Withstanding: 1500VAC for 1 minute, 2550VDC for 1 second
Power
- Internal Power: 3.3V at 400mA, 5V at 425mA
- Backplane: Universal backplane only, PCI bus
Environmental
- Operating Temp: 0 to 60°C (32 to 140°F)
- Storage Temp: -40 to 85°C (-40 to 185°F)
- Humidity: 5% to 95% non-condensing
- Shock: 15G for 11ms
- Vibration: 10-57 Hz 0.0524mm, 57-500 Hz 1.0G
FAQs
-
How many channels does the IC695ALG412 have?
The IC695ALG412 provides 12 individually isolated differential input channels. -
What thermocouple types are supported?
This module supports Types J, K, T, E, R, S, B, N, and C thermocouples. -
What is the resolution of this module?
It features 32-bit IEEE floating point or 16-bit integer (32-bit field) resolution.
Additional Specifications
- Black
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Can DCS Intelligent Regulation Fix Thermal Power Energy Imbalance?
This article explains how intelligent DCS regulation with MPC and cloud-based control solves energy-production imbala...
-
Can Continuous Automation Iteration Cut Factory Costs by 18-25%?
Static industrial control systems create hidden annual cost increases of 18-25%. Phased PLC and DCS program iteration...
-
Can Anti-Interference Hardware End 38% of Automation Downtime?
Field data from chemical, wind, and automotive plants proves that industrial hardware with full IEC 61000-4 EMC certi...
-
How Does Full-Lifecycle Management Optimize PLC and DCS Assets?
Traditional industrial asset management relies on manual logging and reactive troubleshooting, causing 15–20% annual ...
-
Can an Integrated Spare Chain Slash Downtime?
Unplanned equipment failures cost Chinese factories ¥636,000 per hour. Traditional cross-border spare procurement tak...
-
Why Do 30% of Automation Upgrades Fail Due to Integration Gaps?
This technical article explains how digital-intelligent fusion overcomes fragmented workshop operations using industr...