Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:IC693MDL230
IC693MDL230 | GE Fanuc 90-30 Isolated AC Input Module
Manufacturer: General Electric
Product No.: IC693MDL230
Product Type: Isolated Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 300g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
GE Fanuc IC693MDL230 Series 90-30 Isolated AC Input Module
Product Overview
The IC693MDL230 is a high-reliability isolated AC input module designed for the GE Fanuc Series 90-30 Programmable Logic Controller (PLC) system. This module provides eight (8) isolated input points, each capable of handling 120V AC signals. Unlike standard input modules, the isolated design of this hardware allows each input to be powered by a different phase or even a completely different power source, providing unparalleled flexibility in complex industrial wiring environments. It is an essential component for monitoring status signals from motor starters, limit switches, and pushbuttons in high-noise automation settings.
Core Technical Advantages
Engineered for maximum signal integrity, the module supports both 50 and 60 Hertz frequency ranges, ensuring global compatibility. Each input point features a typical input current of 14.5 mA at rated voltage, providing enough load to ensure reliable switching even in the presence of minor leakage currents. A critical safety and performance feature is the 1500V RMS isolation provided between the field-side wiring and the sensitive internal logic-side circuitry. This robust barrier protects the PLC backplane and CPU from high-voltage spikes, ground loops, and transient electrical noise often found in industrial power distribution systems.
Technical Specifications
| Feature | Specification |
|---|---|
| Brand | GE Fanuc |
| Catalog Number | IC693MDL230 |
| Input Type | 120V AC Isolated (8 Points) |
| Frequency Range | 50/60 Hz |
| Product Weight | 0.3 kg (0.66 lbs) |
| Isolation | 1500V RMS (Field to Logic) |
| Input Current | 14.5 mA (Typical) |
Installation & Engineering Guide
The module can be installed in any available I/O slot of a Series 90-30 PLC baseplate. Because each of the 8 inputs is individually isolated, separate common returns must be wired for each circuit if they are using different power sources. When wiring, ensure that AC conductors are routed away from sensitive low-voltage DC signals to further minimize electromagnetic interference. LED indicators on the front of the module provide real-time status of each input point, facilitating quick visual diagnostics during commissioning and maintenance. For optimal performance, ensure all field wiring is securely fastened to the terminal block to maintain consistent electrical contact.
Engineering Advantages
The GE Fanuc Series 90-30 architecture is renowned for its compact footprint and high-density I/O options. Despite its high isolation capabilities, the module maintains a lightweight and efficient profile, with a total weight of just 0.3 kg, reducing the mechanical load on the PLC rack. This module is particularly well-suited for retrofitting legacy systems where various field devices might be powered from different 120V AC transformers. By utilizing the isolated input design, engineers can eliminate the need for interposing relays, thereby reducing cabinet space, simplifying the bill of materials, and enhancing the overall reliability of the automation system.
Technical FAQs
Q1: What does "Isolated Input" mean in this context?
A1: In a standard module, all inputs share a single common return. In this isolated module, each of the 8 inputs has its own isolated return path, allowing you to monitor 8 different circuits that may not share a common ground or power source.
Q2: Can I use this module for 120V DC signals?
A2: No, this module is specifically designed and calibrated for 120V AC alternating current signals. Using DC voltage may lead to inaccurate readings or failure of the input sensing circuitry.
Q3: Is a Certificate of Origin (COO) available for this module?
A3: Yes, as an authorized provider of industrial automation components, we can provide a Certificate of Origin and other necessary compliance documentation upon request.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Can DCS Intelligent Regulation Fix Thermal Power Energy Imbalance?
This article explains how intelligent DCS regulation with MPC and cloud-based control solves energy-production imbala...
-
Can Continuous Automation Iteration Cut Factory Costs by 18-25%?
Static industrial control systems create hidden annual cost increases of 18-25%. Phased PLC and DCS program iteration...
-
Can Anti-Interference Hardware End 38% of Automation Downtime?
Field data from chemical, wind, and automotive plants proves that industrial hardware with full IEC 61000-4 EMC certi...
-
How Does Full-Lifecycle Management Optimize PLC and DCS Assets?
Traditional industrial asset management relies on manual logging and reactive troubleshooting, causing 15–20% annual ...
-
Can an Integrated Spare Chain Slash Downtime?
Unplanned equipment failures cost Chinese factories ¥636,000 per hour. Traditional cross-border spare procurement tak...
-
Why Do 30% of Automation Upgrades Fail Due to Integration Gaps?
This technical article explains how digital-intelligent fusion overcomes fragmented workshop operations using industr...
