Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:MAI51
GE MAI51 369B1841G5007 Analog Input Module 16 Channel
Manufacturer: General Electric
Product No.: MAI51
Product Type: Analog Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
GE MAI51 369B1841G5007 Analog Input Module
The GE MAI51 (369B1841G5007) is a 16-channel analog input module supporting RTD (Pt10, Pt100, Cu100, Cu50) and thermocouple types (E, J, K, N, R, S, T, B). Featuring dual 24 V DC (±10%) redundant power inputs, this module delivers 16-bit resolution with 0.2% measurement accuracy. Weighing approximately 0.5 kg (1.1 lbs), it operates from 0°C to 60°C with CE certification.
Technical Specifications
| Parameter | Value |
|---|---|
| Manufacturer | GE |
| Model | MAI51 (369B1841G5007) |
| Product Type | TC/RTD Analog Input Module |
| Channels | 16 (8 channels per ADC group) |
| Power Supply | Dual 24 V DC ±10% (1:1 Redundant) |
| Power Consumption | < 2 W (Typical 1.8 W) |
| Signal Types | RTD: Pt10, Pt100, Cu100, Cu50; TC: E, J, K, N, R, S, T, B |
| ADC Resolution | 16-bit |
| Measurement Accuracy | 0.2% maximum |
| Over-range Alarm | ±10% (software configurable) |
| CMRR | > 120 dB |
| DMRR | > 60 dB |
| Isolation (Channel-Channel) | 250 V AC |
| Isolation (Channel-Ground) | 500 V AC |
| Isolation (Channel-System) | 1500 V AC |
| Operating Temperature | 0°C to 60°C (32°F to 140°F) |
| Humidity | 10-90% non-condensing |
| Dimensions (H x W x D) | 209 x 129.5 x 51 mm (8.2 x 5.1 x 2.0 in) |
| Weight | Approx. 0.5 kg (1.1 lbs) |
| Mounting | Screw Mounting |
| Communication | Redundant High-Speed Smart Serial Bus (1 Mbps) |
| Connector | Single-row Euro-style, Removable (2.5 mm²) |
| LED Indicators | Run, Communication, Fault Alarm |
| Certification | CE (with system) |
Supported Signal Types
| Sensor Type | Supported Models |
|---|---|
| RTD | Pt10, Pt100, Cu100, Cu50 (2-wire or 3-wire) |
| Thermocouple | E, J, K, N, R, S, T, B |
Installation & Field Application Guide
- Mount the module using screw mounting. Ensure proper grounding for noise immunity.
- Connect dual 24 V DC power supplies (21.6-26.4 V DC range) for 1:1 redundancy.
- Use shielded twisted-pair wiring for RTD and TC signals. Ground shield at the module end only.
- Configure sensor type and range using the system software. Over-range alarm threshold is ±10%.
Why Choose the MAI51 Module
- 16 channels support both RTD and thermocouple inputs in a single module.
- Dual redundant 24 V DC power inputs for high availability applications.
- High isolation (1500 V AC channel-system) ensures reliable operation.
- 0.2% accuracy with 16-bit resolution for precise temperature measurement.
Field Engineer FAQs
Q1: What is the difference between 2-wire and 3-wire RTD connection?
A1: 3-wire connection compensates for lead wire resistance, providing more accurate measurements. 2-wire is suitable for short cable runs where lead resistance is negligible.
Q2: Does the module support cold junction compensation for thermocouples?
A2: Yes, the module provides built-in cold junction compensation when using the terminal block temperature sensor.
Q3: What is the maximum cable length for TC/RTD inputs?
A3: Recommended maximum cable length is 200 meters for shielded twisted-pair wiring. For longer runs, use signal conditioning.
Inquiries: sale@etowonauto.com
Goşmaça spesifikasiýalar
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
Can ABB’s Signal Linkage Cut Downtime 60%?
This article examines how ABB’s multi-layer industrial communication architecture resolves cross-equipment signal mis...
-
Is Your Gas Detection Transmitter Costing You Millions?
Fixed calibration schedules waste millions and hide critical risks. This article presents a data-driven, risk-tiered ...
-
Is Your PLC and DCS Logic Hiding Energy Savings?
This article presents a three-layer framework for industrial energy optimization using ABB automation technology. It ...
-
How Can Real-Time Data Governance Prevent Unplanned Downtime?
Uncalibrated sensors and inconsistent tag naming are causing a trillion-dollar "data debt" in process manufacturing. ...
-
Can Programmable Interlock Eliminate 31% of Assembly Downtime?
This engineering guide examines programmable interlock logic for assembly lines using Allen‑Bradley control platforms...
-
How ABB's Risk Platform Cuts Industrial Plant Downtime?
ABB's intelligent risk identification platform addresses unresolved safety gaps in conventional control-system operat...