Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:IS200EPCTG1A
GE IS200EPCTG1A Simplex Exciter PT CT Terminal Module
Manufacturer: General Electric
Product No.: IS200EPCTG1A
Product Type: Terminal Board
Product Origin: USA
Payment:T/T, Western Union
Weight: 450g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
Product Overview
The General Electric IS200EPCTG1A (functional acronym EPCT) is an Exciter PT/CT Input/Output Terminal Board developed for the GE EX2100 Series Excitation Control System. Designed for process-critical power generation environments, this module receives, conditions, scales, and isolates feedback signals from potential transformers (PTs) and current transformers (CTs) directly monitoring two three-phase generator lines.
Operating on a 28 V DC power supply, the IS200EPCTG1A features integrated isolation transformers (T1 through T6) that convert high-level generator feedback signals into low-voltage signals routed via J305, J308, and J315 connectors to the main controller boards (such as EMIO in M1, M2, or C controllers). Weighing 0.45 kg (0.99 lbs) with compact dimensions of 23.8 cm x 8.6 cm, the board operates across an extended industrial temperature range of -30°C to +65°C.
Core Technical Advantages
- Comprehensive Signal Isolation: Six internal isolation transformers (T1–T6) scale and isolate 115 V rms PT inputs and 1 A/5 A CT current signals for safe system feedback.
- Simplex & Triple Redundant Support: Fully scalable for Simplex systems or redundant control architectures using up to three EPCT boards in parallel.
- Flexible Analog Input Configuration: Features jumper JP1 selection to accept either 0–10 V DC or 4–20 mA field analog instrumentation signals.
- Enhanced Terminal Safety: Features non-removable TB2/TB3 terminal blocks to prevent hazardous CT open-circuit conditions during operational service.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Brand / Manufacturer | General Electric (GE) |
| Part / Catalog Number | IS200EPCTG1A |
| Functional Acronym | EPCT (Exciter PT/CT Terminal Board) |
| System Compatibility | GE EX2100 Excitation Control System |
| PT Input Rating | 115 V rms @ 50/60 Hz (Two 3-phase generator PT inputs) |
| PT Step-Down Voltage Output | 1.533 V rms (from 115 V rms 3-wire open delta input) |
| CT Input Rating | 1 A or 5 A nominal inputs from two generators |
| PT/CT Input Burden | Less than 1 VA |
| Auxiliary Analog Input | 1 Channel: 0 to 10 V DC or 4 to 20 mA (Jumper JP1 selectable) |
| Power Supply Voltage | 28 V DC |
| Terminal Blocks & Wiring | 3 Blocks (TB1 removable; TB2/TB3 fixed); supports up to #10 AWG |
| Board Dimensions | 23.8 cm High x 8.6 cm Wide (9.37 in x 3.38 in) |
| Net Board Weight | 0.45 kg (0.99 lbs) |
| Operating Temperature | -30°C to +65°C (-22°F to +149°F) |
Installation & Gap Calibration Guide
- Field Wiring Connection: Wire CT and PT secondary signals to terminal block TB1 using up to #10 AWG cable (maximum run length 1,000 feet / 300 meters).
- Jumper Configuration: Set jumper JP1 to configure the auxiliary analog input for either 0–10 V DC voltage or 4–20 mA current mode prior to powering up.
- CT Safety Notice: Ensure terminal blocks TB2 and TB3 remain permanently attached to prevent dangerous open-circuit voltage spikes across live CT secondaries.
Technical FAQs
Q1: What is the main function of the GE IS200EPCTG1A terminal board?
A1: It conditions, isolates, and scales generator PT and CT feedback signals for EX2100 exciters. (94 chars)
Q2: Why are terminal blocks TB2 and TB3 non-removable on the IS200EPCTG1A?
A2: They are fixed to protect personnel and equipment from open-circuit CT high-voltage hazards. (95 chars)
Q3: How are secondary signals routed to EX2100 system controllers?
A3: Isolated secondary signals are cabled via J305, J308, and J315 connectors to the EMIO board. (93 chars)
Goşmaça spesifikasiýalar
- Ýaşyl
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
Can Converged PLC-DCS Architecture Cut Downtime by 22%?
This article examines how PLC-DCS convergence resolves the fragmentation bottleneck in legacy process plants. Drawing...
-
Retrofitting Mixed PLC & DCS Systems?
This article presents a hybrid protocol fusion architecture combining Modbus TCP and EtherNet/IP to overcome communic...
-
Original vs Compatible GE Fanuc PLC Parts?
This guide presents a data-driven methodology for identifying and verifying brand-new, original GE Fanuc 90-30, 90-70...
-
Can Data-Driven Alarm Grading Reduce Turbine Downtime?
This technical article presents a data-driven four-tier alarm grading strategy for Bently Nevada 3500 systems in comb...
-
How does ABB S800 I/O hot swap cut unplanned downtime by 90%?
This article presents quantified operational best practices for ABB S800 I/O hot swap in 24/7 process industries. ...
-
Is Your Refinery DCS Ready for Zero-Trust OT Access Control?
This technical article examines data-driven cybersecurity hardening strategies for Emerson DeltaV DCS in refiner...