Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:IS200EISBH1A
GE IS200EISBH1A | EX2100 Series Exciter ISBus Board
Manufacturer: General Electric
Product No.: IS200EISBH1A
Product Type: Exciter Board
Product Origin: USA
Payment:T/T, Western Union
Weight: 280g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
General Electric IS200EISBH1A Exciter ISBus Board (EISB)
The General Electric IS200EISBH1A is a specialized Exciter ISBus Board (EISB) engineered as part of the GE EX2100 Series Excitation Control System. Designed to function in conjunction with the M1, M2, and C control modules, the EISB serves as a lightweight, high-speed communication bridge (approximate weight of 0.28 kg) that receives and transmits fiber-optic feedback signals across cabinet electronics, forwarding crucial real-time operational data via the control backplane directly to the main DSPX controller.
Key System & Functional Features
Housed in a compact, single-slot, 3U-high form factor weighing approximately 0.28 kg (0.62 lbs) and situated directly beneath the DSPX module in the control rack, the IS200EISBH1A handles internal cabinet fiber-optic telemetry and interface routines. It facilitates serial communication between the DSPX and external tool/keypad ports via RS-232C across the backbone connector. For redundant excitation system architectures, the EISB integrates proprietary ISBus interface electronics to ensure seamless data exchange across the M1, M2, and C controllers.
Front Panel Fiber-Optic Channel Mapping
| Generator Field DC Voltage Input | Receives variable frequency voltage signal from Generator Field via EDCF board |
| Generator Field DC Current Input | Receives variable frequency current signal from Generator Field via EDCF board |
| Exciter Voltage Input (Optional) | Receives optional exciter AC/DC voltage feedback from EDCF board |
| Exciter Current Input (Optional) | Receives optional exciter current feedback from EDCF board |
| Ground Detector Input & Output | Bi-directional optical interface connected directly to the EGDM Ground Detection Module |
Technical Specifications
| Manufacturer & Part Number | General Electric | IS200EISBH1A |
| Series & Functional Acronym | EX2100 Excitation Control System | EISB |
| Board Format & Approximate Weight | 3U Single Slot (8.26 cm H x 4.19 cm W) | Approx. 0.28 kg (0.62 lbs) |
| Channels & Input Span | 12 Channels | 4-20 mA Input Span / 0-20 mA Output |
| Signal & Electrical Tolerances | ±5 V Common Mode Voltage Range | 15 Ω Max Lead Resistance |
| Operating Temperature & Manual | -30 °C to +65 °C (-22 °F to +149 °F) | Instruction Manual GEI-100454 |
Installation & Operation Considerations
- Rack Placement & Handling: Due to its lightweight 0.28 kg build, carefully seat the single-slot 3U module into its dedicated control rack slot located immediately below the DSPX processor board without applying excessive mechanical stress to the backplane pins.
- Fiber Optic Cable Handling: Ensure proper bend radius and maintain optical clean-face standards on all 6 front-panel ST/FC fiber connectors to prevent signal attenuation from EDCF/EGDM boards.
- Serial Integration: Verify RS-232C cable pinouts when linking the backbone connector to local keypad terminals or software commissioning tools.
Frequently Asked Questions
Q1: What is the primary role of the IS200EISBH1A in an EX2100 control rack?
A1: It acts as the central fiber-optic interface board that gathers electrical feedback (via EDCF) and ground fault telemetry (via EGDM) and relays it across the backplane to the DSPX controller.
Q2: How does the EISB board support redundant excitation systems?
A2: It houses proprietary ISBus interface electronics enabling seamless high-speed communication and data synchronization between the M1, M2, and C control channels.
Q3: Which instruction manual covers installation and diagnostic routines for this module?
A3: Detailed installation guidelines, pinouts, and system diagnostics are documented in GE Instruction Manual GEI-100454.
Goşmaça spesifikasiýalar
- Ýaşyl
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
How Does TSI Integration Reduce Turbine False Trip Risks?
This article examines data-driven turbine safety monitoring and mechanical fault diagnosis within industrial automati...
-
Can turn-key automation services really cut plant downtime by 47%?
This article examines how fragmented PLC, DCS, TSI, and power-protection systems drive hidden operational losses in p...
-
Is Your Manufacturing Execution Still Stuck in Open-Loop Mode?
This article examines how closed-loop automated control resolves the critical disconnect between production planning ...
-
Can Predictive Analytics Cut Factory Automation Downtime?
This article examines how predictive abnormality pre-judgment technology addresses the economic burden of reactive fa...
-
Is Full PLC Replacement Best for Brown-Field Automation?
This technical article analyzes the hidden costs of full-scale PLC and DCS hardware replacement in brown-field plants...
-
Is Your DCS Logic Tuning Ready for Real-World Production Loads?
This article examines the critical role of physical on-site commissioning and logic tuning in industrial automation, ...
