Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:IC697CHS782
GE Fanuc IC697CHS782 17-Slot VME Integrator Rack
Manufacturer: General Electric
Product No.: IC697CHS782
Product Type: I/O Chassis
Product Origin: USA
Payment:T/T, Western Union
Weight: 8500g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Description
Product Overview
The GE Fanuc IC697CHS782 is a versatile VME Integrator Rack engineered to house and power high-density Series 90-70 automation systems. Featuring a massive 17-slot capacity with standard 0.8-inch spacing, this chassis acts as the physical and electrical foundation for complex PLC configurations. It is designed to accommodate both proprietary GE IC697 modules and open-standard third-party VME modules, providing engineers with maximum flexibility in system design and hardware integration.
Core Technical Performance
The IC697CHS782 is built for high-demand environments, supporting a wide power input range of 90-264VAC (50/60Hz) with a maximum continuous current of 15A. Reliability is prioritized through a built-in slot addressing system, which eliminates the need for external accessories and simplifies module configuration. To protect sensitive electronics, the rack includes a bottom rail grounding system that provides significant EMI reduction (≥30dB at 1GHz), ensuring signal integrity in electrically noisy industrial settings.
Physical Characteristics & Weight
Constructed from a lightweight yet durable aluminum alloy frame, the IC697CHS782 offers industrial-grade protection without excessive bulk. The rack has a net weight of 8.5 kg (approx. 18.7 lbs), making it manageable during installation while maintaining the structural rigidity required for full module loads. Its physical dimensions of 500mm x 400mm x 200mm are optimized for standard industrial cabinetry, though a minimum of 30mm clearance is required to maintain effective natural convection cooling.
Technical Specifications
| Feature | Specification Details |
|---|---|
| Part Number | IC697CHS782 |
| Slot Count | 17 Slots (0.8" spacing) |
| Weight | 8.5 kg (18.7 lb) |
| Power Input | 90-264VAC, 15A Max |
| Material | Aluminum Alloy Frame |
| Operating Temp | -20°C to +60°C |
| EMI Shielding | ≥30dB at 1GHz |
Installation & Cooling
Successful deployment of the IC697CHS782 requires the use of mounting flanges for secure cabinet attachment. While the rack is primarily cooled via natural convection, it is compatible with optional fan assemblies for applications utilizing high-power modules that generate significant heat. Its wide operating temperature range (up to 60°C) and rugged storage ratings make it suitable for global deployment in sectors ranging from power generation to heavy manufacturing.
Technical FAQs
Q1: Can I mix GE IC697 modules with other VME-based cards?
A1: Yes, the IC697CHS782 is designed as a VME integrator rack, meaning it follows VME standards and can host compatible third-party modules alongside GE hardware.
Q2: How does the built-in slot addressing work?
A2: The rack automatically assigns addresses based on the physical slot position of the module, which simplifies the software configuration process and prevents addressing conflicts.
Q3: Is a fan assembly required for all 17 slots?
A3: Not necessarily. Fans are only required if the total power dissipation of the installed modules exceeds the natural convection limits or if the rack is installed in an environment with restricted airflow.
Goşmaça spesifikasiýalar
Scalar (V/f)
Vector
AC-powered
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
DCS-niň akylly düzgünleşdirişi termik elektrik energiýasynyň deňagramsyzlygyny düzedip biler mi?
Bu makalada akylly MPC-li DCS düzgünleşdirmesiniň we bulut bazaly dolandyryşyň ýylylyk elektrik stansiýalarynda energ...
-
Can Continuous Automation Iteration Cut Factory Costs by 18-25%?
Static industrial control systems create hidden annual cost increases of 18-25%. Phased PLC and DCS program iteration...
-
Can Anti-Interference Hardware End 38% of Automation Downtime?
Field data from chemical, wind, and automotive plants proves that industrial hardware with full IEC 61000-4 EMC certi...
-
How Does Full-Lifecycle Management Optimize PLC and DCS Assets?
Traditional industrial asset management relies on manual logging and reactive troubleshooting, causing 15–20% annual ...
-
Can an Integrated Spare Chain Slash Downtime?
Unplanned equipment failures cost Chinese factories ¥636,000 per hour. Traditional cross-border spare procurement tak...
-
Why Do 30% of Automation Upgrades Fail Due to Integration Gaps?
This technical article explains how digital-intelligent fusion overcomes fragmented workshop operations using industr...