Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:V18348-10113300110
Electro-Pneumatic Valve Positioner V18348-10113300110 | ABB
Manufacturer: ABB
Product No.: V18348-10113300110
Product Type: Valve Positioner Module
Product Origin: Sweden
Payment:T/T, Western Union
Weight: 1700g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
ABB V18348-10113300110 TZIDC Valve Positioner
Product Overview
ABB V18348-10113300110 is a TZIDC electro-pneumatic valve positioner with indicator and operator panel. Features varnished aluminum case IP65 (NEMA 4X) for mounting to linear actuators per DIN/IEC 534/NAMUR or rotary actuators per VDI/VDE 3845. Accepts 4-20mA two-wire input with LKS adapter connector. ATEX certified for hazardous areas. Double acting action with configurable fail position. Weight 1.7 kg.
Model Number Decoder
| Position | Code | Meaning |
|---|---|---|
| Base | V18348 | TZIDC Positioner, configurable |
| Case/Mounting | 10 | Aluminum case, IP65, DIN/IEC 534/NAMUR |
| Input/Communication | 1 | 4-20mA two-wire with LKS adapter |
| Explosion Protection | 1 | ATEX certified |
| Output/Safe Position | 3 | Double acting, configurable fail position |
| Connections | 3 | Cable 1/2-14 NPT, Air 1/4-18 NPT |
| Option Modules | 0 | Without position feedback |
| Mech Feedback Kit | 0 | Without |
| Design | 1 | Standard |
Technical Specifications
| Parameter | Value |
|---|---|
| Brand | ABB |
| Model | V18348-10113300110 |
| Type | TZIDC Electro-Pneumatic Valve Positioner |
| Action | Double Acting, Configurable Fail Position |
| Input Signal | 4 to 20 mA two-wire |
| Supply Pressure | 1.4 to 6 bar (20 to 90 psi) |
| Air Capacity at 6 bar | 13 kg/h (6.0 scfm) |
| Air Consumption | < 0.03 kg/h |
| Characteristic Curve | Linear, equal percentage, 20 reference points |
| Characteristic Deviation | ≤ 0.5% |
| Dead Band | 0.1 to 10% adjustable |
| Resolution A/D | > 4000 steps |
| Sample Rate | 20 ms |
| Temp Influence | ≤ 0.5% per 10°C |
| Vibration Influence | ≤ ±1% up to 10g and 80Hz |
| Operating Temperature | 40°C to +85°C |
| Electrical Connection | 1/2-14 NPT |
| Pneumatic Connection | 1/4-18 NPT |
| Protection Class | IP65, NEMA 4X |
| Weight | 1.7 kg (3.75 lbs) |
Installation
Mount on linear actuators per DIN/IEC 534/NAMUR or rotary actuators per VDI/VDE 3845. Connect 4-20mA two-wire input. Wire electrical connection at 1/2-14 NPT. Connect air supply at 1/4-18 NPT with 1.4 to 6 bar pressure. Configure fail position per application requirement. For ATEX hazardous areas, observe certified installation requirements and temperature limits. Verify IP65 seal after installation.
Features
TZIDC configurable valve positioner with indicator and operator panel. Double acting action with configurable fail position. 4-20mA two-wire input with LKS adapter. Characteristic curve with 20 configurable reference points. Characteristic deviation ≤0.5%. Resolution >4000 steps with 20 ms sample rate. Air capacity 13 kg/h at 6 bar supply. ATEX certified for hazardous areas. Aluminum case with epoxy resin varnish IP65 NEMA 4X.
FAQ
Q1: What is the action type of this positioner?
A1: Double acting with configurable fail position. Suitable for both linear actuators per DIN/IEC 534/NAMUR and rotary actuators per VDI/VDE 3845.
Q2: What is the air capacity and supply pressure?
A2: Air capacity 13 kg/h (6.0 scfm) at 6 bar supply. Supply pressure range 1.4 to 6 bar (20 to 90 psi). Air consumption less than 0.03 kg/h.
Q3: What is the resolution and characteristic deviation?
A3: Resolution >4000 steps with 20 ms sample rate. Characteristic deviation ≤0.5%. Dead band adjustable 0.1 to 10%. Weight 1.7 kg.
Goşmaça spesifikasiýalar
- Kümüş
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
How Do You Tune a 3500/92 Gateway for Stable Modbus TCP Polling?
This article explains why Bently Nevada 3500/92 Modbus TCP gateways fail in industrial control systems and how automa...
-
How Can You Prevent GE PLC Backup Failures?
This article explains why GE PLC backup failures occur in RX3i and VersaMax environments. It presents measured root c...
-
Why Does PCS7 OS Server Redundancy Fail Over?
This guide explains how to diagnose and repair Siemens PCS7 OS server redundancy failover anomalies using quantified ...
-
How Do You Recover a Bricked Allen-Bradley PLC?
This article explains how industrial automation teams classify bricked Allen-Bradley Logix controllers, validate firm...
-
How Can You Prevent Historian Data Loss During Experion PKS Migration?
This article presents a measurable playbook for protecting Honeywell Experion historian data during server and H...
-
How Do MTL Barriers and DCS IO Cards Affect Loop Voltage?
Intrinsic safety circuits protect hazardous process areas, yet loop impedance budgeting often receives far less atten...