Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:V18345-2021421001
Double Acting Positioner 4-20 mA | New ABB V18345
Manufacturer: ABB
Product No.: V18345-2021421001
Product Type: Valve Positioner Module
Product Origin: Sweden
Payment:T/T, Western Union
Weight: 1700g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
ABB V18345-2021421001 TZIDC Electro-Pneumatic Positioner
The V18345-2021421001 (also cataloged as the V18345 Electro-Pneumatic Positioner) is a TZIDC intelligent positioner in a varnished aluminium case rated IP 65 (NEMA 4X). It accepts a 4-20 mA two-wire HART input and provides double-acting fail-safe output, with ATEX Ex II 2 G EEx ib II C T6 explosion protection. Unit weight is 1.7 kg.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | V18345-2021421001 |
| Brand | ABB |
| Product Type | TZIDC Electro-Pneumatic Positioner |
| Housing | Aluminium, IP 65 / NEMA 4X, RAL 9005 matte black |
| Weight | 1.7 kg |
| Input Signal | 4 to 20 mA, two-wire, HART via FSK module |
| Explosion Protection | ATEX Ex II 2 G EEx ib II C T6 |
| Output Function | Double acting, fail safe |
| Supply Pressure | 1.4 to 6 bar (20 to 90 psi) |
| Air Consumption | < 0.03 kg/h / 0.015 scfm |
| Pneumatic Connections | Threads G 1/4 or 1/4-18 NPT |
| Electrical Connections | Cable: Thread 1/2-14 NPT |
| Digital Input | 0-5 V DC logical 0; 11-30 V DC logical 1 |
| Digital Output | 5 to 11 V DC, DIN 19234/NAMUR |
| Position Feedback | Plug-in analog module, 4-20 mA |
Signal and Characteristic Curve Control
The V18345-2021421001 uses two-wire technology with a nominal 4-20 mA signal range, where 4 mA corresponds to 0 % and 20 mA to 100 % position. Split range operation is freely selectable with a minimum range of 20 % (3.2 mA) and a recommended range above 50 % (8.0 mA). The signal action is configurable as direct (4-20 mA = position 0-100 %) or reverse (20-4 mA = position 0-100 %). The travel characteristic is selectable as linear, equal percentage at 1:25 or 1:50, 25:1 or 50:1, or user-configurable with 20 reference points. The digital input activates a selected protective function when the 24 V DC signal drops below 10 V DC; selectable functions include move to 0 %, move to 100 %, hold last position, disable local configuration, disable local configuration and operation, or disable any access. The HART FSK module enables remote configuration through the 4-20 mA loop. The digital output follows the DIN 19234/NAMUR control circuit at 5-11 V DC.
Field Installation Guidelines
Mount the positioner to a linear actuator per DIN/IEC 534 / NAMUR or to a rotary actuator per VDI/VDE 3845 using the mechanical position indicator. Verify the hazardous area classification matches ATEX Ex II 2 G EEx ib II C T6 and confirm the input loop is intrinsically safe before wiring. Confirm the 1.7 kg unit is supported by the actuator mounting bracket. Connect the 4-20 mA HART input through the 1/2-14 NPT cable entry and the air supply through the G 1/4 or 1/4-18 NPT port. Verify supply air is dry and oil-free within 1.4 to 6 bar. For double-acting actuators, connect both pneumatic outputs and verify fail-safe action before pressurizing. Route signal wiring separately from AC power conductors and maintain the case seal for IP 65 / NEMA 4X integrity. Set split range, characteristic curve, and digital input function through the local panel or HART configuration before placing the loop in service.
Frequently Asked Questions
Q: What is the explosion protection rating of the V18345-2021421001?
A: ATEX Ex II 2 G EEx ib II C T6.
Q: What is the output function and supply pressure range?
A: Double acting, fail safe; supply pressure 1.4 to 6 bar (20 to 90 psi).
Q: What is the minimum split range and recommended split range?
A: Minimum range 20 % (3.2 mA); recommended range above 50 % (8.0 mA).
Goşmaça spesifikasiýalar
- Kümüş
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
How Does the Bently Nevada 3500/42M Vibration Module Drift?
This technical guide examines the Bently Nevada 3500/42M vibration module within industrial automation architect...
-
What Causes IC694MDL Fault Codes in GE RX3i PLC Systems?
This guide explains GE RX3i IC694MDL discrete I/O fault codes, key electrical parameters, ESD and torque requirements...
-
What CFC Rules Cut PCS7 Batch Abort Rates Fast?
This article presents enforceable CFC programming governance rules for Siemens PCS7 DCS batch plants, covering b...
-
What Makes the 1769-L3ER Ideal for Compact Skid Automation?
This guide explains how the Allen-Bradley 1769 CompactLogix L3ER bridges the gap between micro PLCs and large DC...
-
Why Do SIL3 Safety Interlocks Still Trip in Industrial Plants?
This article reviews Honeywell Safety Manager SIL3 SIS architecture, wiring and cabinet installation rules, PFDa...
-
How Does Poor Grounding Cause 4-20mA Signal Drift?
This guide explains how MTL signal isolators fail through distortion, drift and EMI in PLC and DCS loops, then d...