Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:VFD900CP43A-00
Delta VFD900CP43A-00 90kW AC Drive 460V Light Duty 180A
Manufacturer: Delta
Product No.: VFD900CP43A-00
Product Type: AC Drive
Product Origin: CN
Payment:T/T, Western Union
Weight: 38400g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
Delta VFD900CP43A-00 CP2000 Series Drive
The Delta VFD900CP43A-00 is a powerful industrial AC drive. It is part of the efficient CP2000 series. This model provides 125 HP (90 kW) output. It operates on 460V three-phase power. The drive features a built-in DC reactor for better power quality. It has a compact D frame design. This drive suits various industrial motor control applications.
Key Features and Benefits
- High Power Output: 125 HP (90 kW) for demanding motor control.
- Built-in DC Reactor: Reduces harmonics and improves power factor.
- Compact Design: D frame size saves valuable panel space.
- Dual Current Ratings: Supports both light duty (180A) and normal duty (150A) operation.
- Energy Efficient: CP2000 series designed for optimal energy savings.
Complete Technical Specifications
- Manufacturer: Delta
- Model: VFD900CP43A-00
- Series: CP2000
- Input Voltage: 460V - 3 Phase
- Rated Power: 125 HP (90 kW)
- Light Duty Current: 180 A
- Normal Duty Current: 150 A
- Frame Size: D
- IP Rating: IP00 (Open Frame)
- Built-in EMC Filter: No
- Built-in Braking Chopper: No
- Built-in DC Reactor: Yes
- Weight: 84.7 lbs (38.4 kg)
- Dimensions: 10.83" x 12.99" x 21.65" (275mm x 330mm x 550mm)
- Cooling Method: Forced air cooling
- Control Method: Advanced vector control technology
- Carrier Frequency: Adjustable range 1-16 kHz
- Efficiency: >97% typical
- Ambient Temperature: -10°C to 50°C (14°F to 122°F) for operation
- Storage Temperature: -20°C to 65°C (-4°F to 149°F)
- Humidity: 0-90% RH (non-condensing)
- Overload Capacity: 110% for 60 seconds (normal duty)
- Control Interface: Standard digital and analog I/O
Installation and Setup
- Mount in a clean, dry, well-ventilated enclosure (IP00 rating requires full enclosure protection).
- Maintain proper clearance for airflow around the drive.
- Use appropriate wire gauges for 150-180A current ratings.
- Install external EMC filter if required by application.
- Add external braking unit and resistor for dynamic braking needs.
- Ensure proper grounding according to electrical standards.
Typical Applications
- Centrifugal pumps and water supply systems.
- Industrial fans and air handling units.
- Conveyor systems and material handling equipment.
- Mixers and agitators in processing industries.
- HVAC systems in large buildings.
Frequently Asked Questions (FAQ)
Q: What is the difference between light duty and normal duty current ratings?
- A: Light duty (180A) allows higher current for lighter loads with frequent starts/stops. Normal duty (150A) is for continuous heavy loads with fewer start/stop cycles.
Q: Does this drive have built-in braking capability?
- A: No. You need to add an external braking chopper and resistor for applications requiring rapid deceleration or braking.
Q: Can this drive be used outdoors?
- A: No. With IP00 rating, it must be installed inside a protective enclosure that provides appropriate environmental protection.
Goşmaça spesifikasiýalar
- Gara
- Çal
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
Can a Multi-Vendor PM Checklist Cut PLC Downtime?
This article presents a standardized annual preventive maintenance checklist for mixed-vendor industrial control envi...
-
Why Emerson Hot Redundancy Retrofit Slashes Downtime by 96%?
Process plants relying on GE Fanuc single PLCs face 47% of unplanned outages from controller failure, costing $38,000...
-
Cut Migration Engineering Hours by 60% – How Does It Work?
This technical guide examines the operational risks and engineering overhead of maintaining separate GE Proficy HMI a...
-
Is Your 1756 Supply Chain Risking Production?
Counterfeit 1756 modules cause 68% of unplanned PLC downtime. This guide covers a four-step verification method, real...
-
Why Do 72% of Analog Loop Failures Trace Back to Wiring Errors?
This technical guide presents field-verified wiring protocols for integrating Emerson Rosemount 4–20mA HART transmitt...
-
GE Fanuc VersaMax: Did It Replace Obsolete ABB AC500-ECO?
This technical case study details a complete control system retrofit for a 1200m³/day municipal water plant. Our team...