Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:VFD485VP43AFTHA
Delta VFD485VP43AFTHA | 3-Phase 460V 91A Drive
Manufacturer: Delta
Product No.: VFD485VP43AFTHA
Product Type: AC Drive
Product Origin: CN
Payment:T/T, Western Union
Weight: 8000g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Description
Product Overview
The Delta VFD485VP43AFTHA is a high-capacity Variable Frequency Drive (VFD) engineered for heavy-duty industrial fluid control. With a robust output of 45kW (60HP), this drive excels in managing large-scale HVAC systems, water treatment pumps, and industrial cooling towers. This specific "THA" variant incorporates enhanced thermal management and an integrated DC reactor to suppress harmonic distortion, ensuring compliance with strict power quality standards. Its advanced Sensorless Vector Control (SVC) provides the perfect balance between high starting torque and energy-efficient cruise speeds.
Technical Configuration
Model Specification Logic
- Power Rating (485): Delivers a rated output current of 91 Amps, supporting motors up to 45kW (60HP).
- Series (VP): Specialized for variable torque loads, offering a multi-pump control mode and fire mode for emergency fan operation.
- Voltage Class (43): 460V 3-Phase input (compatible with 380V–480V ±10% utility grids).
- Filter & Reactor (AF): Includes a built-in EMC filter (Class A) and an internal DC reactor to reduce THDi (Total Harmonic Distortion).
- Frame Configuration (THA): Features a reinforced chassis with an independent cooling duct design to isolate power components from dust.
Technical Specifications
| Parameter | Data Value Details |
|---|---|
| Rated Output Current | 91 A (Normal Duty) |
| Applicable Motor Output | 45 kW / 60 HP |
| Input Current | 86 A (3-Phase AC) |
| Braking Torque | Approx. 20% (Standard); up to 125% with external unit |
| Starting Torque | 150% at 0.5Hz (SVC mode) |
| Frequency Stability | Digital: ±0.01%; Analog: ±0.2% |
| Efficiency | ≥ 97.5% at rated load |
| Enclosure Rating | IP20 (Standard) / NEMA 1 Optional |
Installation & Maintenance Guide
High-Power Engineering Standards
Power Quality: The integrated DC reactor in the VFD485VP43AFTHA significantly reduces harmonics. No additional line reactor is required unless the power source impedance is less than 3%. This reduces both installation footprint and overall system cost.
Cooling Architecture: This model utilizes an isolated cooling duct. When mounting in a cabinet, ensure the exhaust air is vented directly out of the enclosure to prevent internal heat buildup. The drive’s fans are field-replaceable to ensure long-term uptime.
Torque Terminal Torque: For the 91A output terminals, use M6 or M8 ring terminals with a tightening torque of 4.0-5.0 N-m to prevent hot spots caused by loose electrical connections.
Engineering Advantages
The VFD485VP43AFTHA features an Advanced Multi-Pump Control logic, capable of managing up to 4 pumps simultaneously (1 master fixed speed + 3 auxiliary). It includes a built-in RS-485 interface supporting Modbus RTU/ASCII with speeds up to 38.4kbps. Its 4-layer conformal coating protects the 45kW power bridge and control logic from moisture and chemical vapors, making it suitable for wastewater treatment facilities and chemical processing plants.
Technical FAQs
Q1: What is the maximum carrier frequency for this 45kW model?
A1: The carrier frequency can be set between 2kHz and 10kHz. For a 45kW drive, 4kHz is the recommended default to balance switching losses and acoustic motor noise.
Q2: Can I run this drive on a single-phase supply for testing?
A2: No. High-power VP series drives require a balanced 3-phase input to prevent phase-loss protection trips and potential damage to the input rectifier bridge.
Q3: How does the "Fire Mode" work in this drive?
A3: When activated via a digital input, the VFD ignores non-critical alarms and runs at a preset frequency to ensure smoke extraction or water pressure is maintained during emergency events.
Goşmaça spesifikasiýalar
- Black
- Gray
Scalar (V/f)
Vector
AC-powered
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
Can DCS Intelligent Regulation Fix Thermal Power Energy Imbalance?
This article explains how intelligent DCS regulation with MPC and cloud-based control solves energy-production imbala...
-
Can Continuous Automation Iteration Cut Factory Costs by 18-25%?
Static industrial control systems create hidden annual cost increases of 18-25%. Phased PLC and DCS program iteration...
-
Can Anti-Interference Hardware End 38% of Automation Downtime?
Field data from chemical, wind, and automotive plants proves that industrial hardware with full IEC 61000-4 EMC certi...
-
How Does Full-Lifecycle Management Optimize PLC and DCS Assets?
Traditional industrial asset management relies on manual logging and reactive troubleshooting, causing 15–20% annual ...
-
Can an Integrated Spare Chain Slash Downtime?
Unplanned equipment failures cost Chinese factories ¥636,000 per hour. Traditional cross-border spare procurement tak...
-
Why Do 30% of Automation Upgrades Fail Due to Integration Gaps?
This technical article explains how digital-intelligent fusion overcomes fragmented workshop operations using industr...
