Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:VFD5A5MS43ANSAA
Delta MS300 VFD5A5MS43ANSAA | 3HP Motor
Manufacturer: Delta
Product No.: VFD5A5MS43ANSAA
Product Type: AC Drive
Product Origin: CN
Payment:T/T, Western Union
Weight: 1270g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Delta VFD5A5MS43ANSAA Industrial Frequency Drive
The Delta VFD5A5MS43ANSAA provides reliable 3HP motor control in the MS300 series. This efficient drive delivers precise speed regulation for industrial applications. It combines compact design with robust performance capabilities.
Electrical Specifications
- Manufacturer: Delta Electronics
- Product Code: VFD5A5MS43ANSAA
- Input Power: 460V AC Three Phase, 50/60Hz ±10%
- Output Power: 3 Horsepower (2.2 Kilowatts)
- Current Ratings: 6.5A Normal Duty, 5.5A Heavy Duty
- Frequency Range: 0.1 to 599 Hz programmable output
- Efficiency Class: >97% typical operating efficiency
Physical Characteristics
- Unit Weight: 2.8 Pounds (1.27 kilograms)
- Dimensions: 3.43" W × 6.18" H × 5.98" D (87×157×152mm)
- Frame Design: Space-saving C1 frame design
- Cooling Method: Natural convection cooling system
Control Performance
- Control Methods: V/F Control, Enhanced Sensorless Vector
- Overload Capacity: 150% for 60 seconds, 180% for 3 seconds
- Speed Regulation: ±0.5% speed control accuracy
- Braking Torque: 20% built-in DC injection braking
- Control Terminals: 6 digital inputs, 2 analog inputs, 2 relay outputs
Environmental Ratings
- Operating Temperature: -10°C to +45°C (14°F to 113°F)
- Humidity Range: 5% to 95% non-condensing
- Altitude Rating: 1000 meters without derating
- Vibration Resistance: 1.5G (10-60Hz) industrial standard
- Protection Class: IP20 for cabinet installation
Application Solutions
- What applications suit this 3HP drive? Pumps, fans, conveyors, machine tools
- What communication interfaces included? Standard RS-485 MODBUS support
- Is external braking required? Optional for higher braking demands
Additional Specifications
- Black
- Gray
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Can DCS Intelligent Regulation Fix Thermal Power Energy Imbalance?
This article explains how intelligent DCS regulation with MPC and cloud-based control solves energy-production imbala...
-
Can Continuous Automation Iteration Cut Factory Costs by 18-25%?
Static industrial control systems create hidden annual cost increases of 18-25%. Phased PLC and DCS program iteration...
-
Can Anti-Interference Hardware End 38% of Automation Downtime?
Field data from chemical, wind, and automotive plants proves that industrial hardware with full IEC 61000-4 EMC certi...
-
How Does Full-Lifecycle Management Optimize PLC and DCS Assets?
Traditional industrial asset management relies on manual logging and reactive troubleshooting, causing 15–20% annual ...
-
Can an Integrated Spare Chain Slash Downtime?
Unplanned equipment failures cost Chinese factories ¥636,000 per hour. Traditional cross-border spare procurement tak...
-
Why Do 30% of Automation Upgrades Fail Due to Integration Gaps?
This technical article explains how digital-intelligent fusion overcomes fragmented workshop operations using industr...