Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:3500/25-01-01-02
Bently Nevada 3500/25-01-01-02 Enhanced Keyphasor Module
Manufacturer: Bently Nevada
Product No.: 3500/25-01-01-02
Product Type: Enhanced Keyphasor Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 460g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
Bently Nevada 3500/25-01-01-02 Enhanced Keyphasor Module
Bently Nevada 3500/25-01-01-02 Enhanced Keyphasor Module for 3500 Machinery Protection System. Half-height, two-channel module converts proximity probe or magnetic pickup signals into digital Keyphasor outputs. ATEX/IECEx/CSA certified for Class 1 Zone 2 hazardous areas. Provides precise timing for shaft speed, phase, and vector measurements.
Key Features
2-channel half-height module. Input range 1 to 1,200,000 cpm (0.017 to 20 kHz). Output range 1 to 99,999 cpm. Auto or manual threshold triggering. Buffered Keyphasor outputs at front and rear. -24 Vdc transducer power supply. 3.2W typical power consumption. ATEX/IECEx/CSA Class 1 Zone 2 approval. Supports up to four Keyphasor signals standard, eight in paired configuration. Direct replacement for 125792-01.
Technical Specifications
| Manufacturer | Bently Nevada |
| Part Number | 3500/25-01-01-02 |
| Product Type | Enhanced Keyphasor Module |
| Channels (Option A) | 01 = Single 2-channel card |
| I/O Module Type (Option B) | 01 = Internal Terminations |
| Agency Approval (Option C) | 02 = ATEX/IECEx/CSA (Class 1 Zone 2) |
| Input Frequency Range | 1 to 1,200,000 cpm (0.017 to 20 kHz) |
| Output Frequency Range | 1 to 99,999 cpm (0.017 to 1667 Hz) |
| Accuracy (Non-processed) | ±1 cpm (0.017-100Hz), ±8 cpm (101-500Hz), ±1% (501-20kHz) |
| Input Impedance | 21.8 kΩ minimum |
| Auto Threshold | 2V p-p min, 120 rpm (2Hz) min |
| Manual Threshold | 0 to -20Vdc, 500mV p-p min |
| Hysteresis | User-selectable 0.2 to 2.5V |
| Transducer Power Supply | -24 Vdc, 40 mA max per channel |
| Power Consumption | 3.2 W typical |
| Main Module Dimensions | 119.9 x 24.4 x 256.5 mm (4.72 x 0.96 x 10.10 in) |
| Main Module Weight | 0.34 kg (0.76 lbs) |
| I/O Module Dimensions | 241.3 x 24.4 x 103.1 mm (9.50 x 0.96 x 4.06 in) |
| I/O Module Weight | 0.46 kg (1.01 lbs) |
| Rack Space (Main) | 1 half-height front slot |
| Rack Space (I/O) | 1 full-height rear slot |
| Operating Temperature | -30°C to +65°C |
| Storage Temperature | -40°C to +85°C |
| Humidity | 95%, non-condensing |
| Origin | Made in U.S.A. |
Ordering Code Breakdown
3500/25-01-01-02
A:01 – Single half-height 2-channel Keyphasor card.
B:01 – I/O module with Internal Terminations.
C:02 – ATEX/IECEx/CSA (Class 1 Zone 2) approval.
Installation Notes
Install in half-height front slot using mounting adapter. I/O module occupies corresponding full-height rear slot. For hazardous area installation, follow control drawing 149243 or 149244. Configure trigger threshold (auto or manual) and hysteresis per application. Use Internal Terminations (B:01) for standard proximity probe applications.
Engineering Advantages
ATEX/IECEx/CSA Class 1 Zone 2 certification enables installation in hazardous areas. Supports up to eight Keyphasor signals in paired configuration. Expanded frequency range handles multi-event-per-turn inputs up to 20 kHz. Direct replacement for legacy 125792-01 modules. Buffered outputs at front and rear simplify external diagnostics. Field-upgradeable firmware protects investment.
FAQs
Q1: What is the maximum input frequency?
A1: 20 kHz (1,200,000 cpm), supporting multiple events per revolution.
Q2: What approvals does the 02 option provide?
A2: ATEX/IECEx/CSA certification for Class 1 Zone 2 hazardous areas.
Q3: Can this module replace older Keyphasor modules?
A3: Yes, the Enhanced Keyphasor Module is a direct plug-in replacement for Keyphasor Module 125792-01.
Goşmaça spesifikasiýalar
- Gök
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
How Does TSI Integration Reduce Turbine False Trip Risks?
This article examines data-driven turbine safety monitoring and mechanical fault diagnosis within industrial automati...
-
Can turn-key automation services really cut plant downtime by 47%?
This article examines how fragmented PLC, DCS, TSI, and power-protection systems drive hidden operational losses in p...
-
Is Your Manufacturing Execution Still Stuck in Open-Loop Mode?
This article examines how closed-loop automated control resolves the critical disconnect between production planning ...
-
Can Predictive Analytics Cut Factory Automation Downtime?
This article examines how predictive abnormality pre-judgment technology addresses the economic burden of reactive fa...
-
Is Full PLC Replacement Best for Brown-Field Automation?
This technical article analyzes the hidden costs of full-scale PLC and DCS hardware replacement in brown-field plants...
-
Is Your DCS Logic Tuning Ready for Real-World Production Loads?
This article examines the critical role of physical on-site commissioning and logic tuning in industrial automation, ...