Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:330505-01-02-00
Bently Nevada 330505-01-02-00 Low Frequency Velocity Sensor
Manufacturer: Bently Nevada
Product No.: 330505-01-02-00
Product Type: Velocity Sensor
Product Origin: USA
Payment:T/T, Western Union
Weight: 375g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Description
Product Overview
The 330505-01-02-00 is a specialized low-frequency velocity sensor engineered by Bently Nevada for monitoring slow-speed industrial machinery. Unlike standard seismic sensors, this transducer is optimized for applications like hydroelectric turbines or large cooling fans, where detecting vibrations at frequencies as low as 0.5 Hz is vital for safety. By utilizing advanced internal sensing technology, it delivers high-resolution casing velocity data, enabling maintenance teams to identify mechanical imbalances or structural resonances before they cause catastrophic equipment failure.
Technical Configuration
The 330505-01-02-00 features a precise mechanical build designed for vertical integration. The suffix "-01" indicates a 0° vertical mounting orientation (±10°), ensuring accurate sensitivity along the machine's primary axis of movement. This specific model utilizes a 3/8-24 UNF-2B internal mounting thread and comes without an external adapter (-00 option). Housed in 300-series stainless steel with a hermetically sealed 2-pin Mil-C-5015 connector, the hardware is designed to maintain zero signal degradation over cable lengths reaching up to 305 meters when connected to Bently Nevada 3500/46M monitors.
Technical Specifications
| Parameter | Specification |
|---|---|
| Sensitivity | 20 mV/mm/s (508 mV/in/s) ±10% |
| Frequency Response | 0.5 Hz to 1000 Hz (±3.0 dB) |
| Velocity Range | 102 mm/s (4 in/s) peak |
| Weight | < 375 grams (13.2 oz) |
| Operating Temp | -40°C to +100°C |
| Output Bias Voltage | -12 ±1 VDC |
Installation & Maintenance Guide
To ensure peak performance of the 330505-01-02-00, the sensor must be rigidly mounted to the target surface with a maximum torque of 46 kg·cm. The mounting surface should be flat and clean to prevent signal attenuation at higher frequencies. As a vertical sensor (-01), it must stay within ±10° of the vertical axis to maintain calibration. Use shielded cabling to protect the low-frequency signal from electromagnetic interference (EMI), especially when operating near large motors or high-voltage switchgear.
Engineering Advantages
The 330505-01-02-00 stands out for its exceptional amplitude linearity (±3%) and shock survivability of up to 100g. Its hermetically sealed 300-series stainless steel case allows for continuous operation in 100% relative humidity environments (non-submerged). This durability, combined with the ability to transmit data over 305 meters without signal loss, makes it the industry standard for predictive maintenance programs in hydroelectric plants and wastewater treatment facilities where remote monitoring is required.
Technical FAQs
Q1: Why is a low-frequency response of 0.5 Hz important?
A1: Slow-turning machines like hydro turbines rotate at low RPMs; standard sensors often lose sensitivity at these speeds, whereas this sensor captures the fundamental vibration frequencies accurately.
Q2: What is the "No Adapter" (-00) option for?
A2: This option is intended for installations where the machine already has a compatible 3/8-24 UNF-2B mounting stud, allowing for a direct and more rigid mechanical connection.
Q3: How is the sensor polarity defined?
A3: Pin A becomes positive relative to Pin B when the velocity is applied from the base toward the top of the transducer, facilitating correct phase-angle measurement for balancing.
Goşmaça spesifikasiýalar
Scalar (V/f)
Vector
AC-powered
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
DCS-niň akylly düzgünleşdirişi termik elektrik energiýasynyň deňagramsyzlygyny düzedip biler mi?
Bu makalada akylly MPC-li DCS düzgünleşdirmesiniň we bulut bazaly dolandyryşyň ýylylyk elektrik stansiýalarynda energ...
-
Can Continuous Automation Iteration Cut Factory Costs by 18-25%?
Static industrial control systems create hidden annual cost increases of 18-25%. Phased PLC and DCS program iteration...
-
Can Anti-Interference Hardware End 38% of Automation Downtime?
Field data from chemical, wind, and automotive plants proves that industrial hardware with full IEC 61000-4 EMC certi...
-
How Does Full-Lifecycle Management Optimize PLC and DCS Assets?
Traditional industrial asset management relies on manual logging and reactive troubleshooting, causing 15–20% annual ...
-
Can an Integrated Spare Chain Slash Downtime?
Unplanned equipment failures cost Chinese factories ¥636,000 per hour. Traditional cross-border spare procurement tak...
-
Why Do 30% of Automation Upgrades Fail Due to Integration Gaps?
This technical article explains how digital-intelligent fusion overcomes fragmented workshop operations using industr...
