Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:330103-00-03-10-02-05
Bently Nevada 330103-00-03-10-02-05 Proximity Probe
Manufacturer: Bently Nevada
Product No.: 330103-00-03-10-02-05
Product Type: Proximity Probe
Product Origin: USA
Payment:T/T, Western Union
Weight: 323g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
Bently Nevada 330103-00-03-10-02-05 Overview
The Bently Nevada 330103-00-03-10-02-05 is a high-precision 3300 XL 8mm proximity probe engineered for continuous, industrial-grade machinery monitoring and vibration detection. Featuring a rugged 30mm stainless steel unthreaded housing coupled with a Polyphenylene Sulfide (PPS) tip, this probe delivers exceptional chemical and environmental resistance. It provides stable eddy current measurement paths across an active range of 0.25 to 2.3 mm (10 to 90 mils), yielding a highly accurate linear voltage output mapping from -1 to -17 Vdc. Weighing approximately 323g/m, it is heavily favored for mission-critical deployments across volatile, hazardous industrial environments.
Core Technical Advantages
Excellent Thermal & Chemical Endurance
The sensor assembly withstands extreme temperature ranges, supporting probe tip operation from -62°F to +425°F and coaxial cabling paths up to +500°F. The robust PPS tip construction protects the internal sensing coils against corrosive machine fluids and lubricants.
Secure ClickLoc Micro-Coaxial Connection
Equipped with an integrated 1.0-meter coaxial cable terminating in a specialized ClickLoc connector. This mechanism provides a robust, vibration-resistant locking joint that prevents signal attenuation or intermittent connection dropouts caused by high-frequency machinery harmonics.
Hazardous Area Classification
Fully certified for global hazardous area operation under ATEX, IECEx, and CSA standards. It is rated for Zone 0 (AEx ia IIC T1-T5) intrinsically safe installations as well as Zone 2 (AEx nA/ec IIC T1-T5) safe-operating schemas spanning Groups A through G.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Product Model | 330103-00-03-10-02-05 |
| Product Series Architecture | 3300 XL 8mm Proximity Transducer System |
| Manufacturer / Brand | Bently Nevada (Baker Hughes) |
| Housing Size & Thread | 30mm case length; M10×1 mechanical thread (15mm max thread length) |
| Linear Measurement Range | 0.25 to 2.3 mm (10 to 90 mils range boundaries) |
| Dynamic Signal Output | -1 Vdc to -17 Vdc linear voltage scale |
| Optimal Sensor Gap Calibration | -9 Vdc electrical bias point (matching 50 mils center gap) |
| Electrical Resistive Accuracy | 7.59 Ω ± 0.50 Ω nominal tolerance bounds |
| Integrated Cable Layout | 1.0-meter coaxial line configured with ClickLoc termination connector |
| Humidity & Environmental Drift | <3% Average Scale Factor (ASF) change when exposed to 93% RH |
| Net Mass Weight | 323 grams per meter (approx. 0.323 kg/m density profile) |
| Explosion Protection Codes | Zone 0: AEx ia IIC T1-T5 | Zone 2: AEx nA/ec IIC T1-T5 |
Installation & Engineering Guide
Mechanical Alignment and Gap Setup
Mount the 30mm probe body securely through the machine casing wall using the M10×1 thread profile. Adjust the physical gap distance relative to the target shaft surface until your digital voltmeter registers exactly -9 Vdc at the Proximitor sensor output terminal, validating the perfect 50 mils centerline operating gap.
Field Extension Wiring Parameters
When extending the sensor loop to your central control cabinet or monitoring rack, use a 3-conductor shielded triad wire layout (16 to 24 AWG recommended). Keep the total field extension length restricted within a maximum wiring threshold of 1,000 feet to prevent parasitic line resistance from altering high-frequency vibration readouts.
Environmental Limitations & Sealing
The module includes a standard Viton® O-ring seal designed for splash resistance; however, this assembly is not pressure-tested from the factory. If your deployment requires pressure containment across casing boundaries, specific custom pressure certificates must be requested. Avoid operating the coaxial assembly below -30°F to mitigate physical cable jacket cracking risks.
Technical FAQs
Q1: What does the 323g/m physical weight specification imply for field engineering?
A1: The 323g/m rating indicates the exact hardware density profile of the combined probe body and shielded coaxial line, giving installation engineers structural data for calculating strain relief bracket loads on long cable runs.
Q2: Can the 330103-00-03-10-02-05 probe handle high-pressure fluid environments out of the box?
A2: No. While it features a premium Viton® O-ring assembly for chemical isolation, the default configuration is not certified for pressure barriers. Pressure-tested options are constructed custom-to-order upon request.
Q3: How does high relative humidity affect the operational accuracy of this 8mm probe?
A3: The probe features a hermetically sealed assembly that restricts the Average Scale Factor (ASF) drift to less than 3% even under continuous exposure to 93% relative humidity conditions, maintaining linear feedback accuracy.
Goşmaça spesifikasiýalar
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
Näme üçin Akylly Tor Şahamça Elektrik Saklamasynda PLC-ni DCS bilen Integrirlemeli?
Bu makalada GE Fanuc 90 PLC bilen Emerson DCS-iň integrasiýasynyň elektrik ulgamlary boýunça iri göwrümli saklaýyş mü...
-
Ýarym-gurluşyk önümçiliginde “gatnap” galanyňyz barmy? Arzan “PLC-DCS” garyşyk ulgamy synap görüň.
Kiçi partiýaly himiki önüm öndürijiler gadagan ediji çykdajylarsyz Senagat 4.0-ä geçip bilerler. Rockwell PLC we ABB ...
-
ABB Marine PLC deňizde 50 g wibrasiýa şertlerinde işläp bilýärmi?
Bu makalada Emerson Kappa DCS we ABB Marine PLC ulgamlarynyň deňizdäki himiki gämileri dolandyrmakdaky agyr şertlerdä...
-
Haky Önümler Bökdençsiz Durmuş Wagty 70% Azaldyp Bilermi?
Könelen PLC we DCS enjamlary meýilleşdirilmedik dykylmalaryň köpüsine sebäp bolýar. Bu gollanma näsazlyk töwekgelçili...
-
Markaly PLC-DCS ulgamlarynyň utgaşykly işlemegi akylly portlardaky maglumat siloslaryna çözgüt bolup biler mi?
Bu tehniki makala akylly port gurşawlarynda maglumat izolýasiýasyny we meýilnama ýetmezçiliklerini çözmekde GE Fanuc ...
-
Dürli Öndürijili PLC we DCS Ulgamlary Birikdirilip Bökdençsiz Işläp Bilermi?
Bu makalada dürli görnüşli senagat dolandyryş ulgamlarynyň işjeňlige edýän täsiri seljerilip, Allen-Bradley, ABB, GE ...
