Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:1746-OA8
Allen-Bradley SLC 500 8-Point AC Output Module 1746-OA8
Manufacturer: Allen-Bradley
Product No.: 1746-OA8
Product Type: AC Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 350g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
Product Overview
The Allen-Bradley 1746-OA8 is an 8-point discrete AC output module engineered for the SLC 500 modular control system by Rockwell Automation. Designed for controlling AC-powered loads such as solenoids, motor starters, relays, and indicator lamps, this module operates across a nominal 120/240 V AC supply voltage with a broad operating range of 85 to 264 V AC (47–63 Hz).
Organized into two (2) individually isolated groups of four (4) output channels each, the 1746-OA8 delivers reliable signal isolation and surge protection for industrial automation systems. Weighing approximately 0.35 kg (0.77 lbs), it installs into any single slot of an SLC 500 chassis, drawing a low 185 mA at 5 V DC from the backplane power supply.
Core Technical Advantages
- Dual Grouped Channel Architecture: Features 8 AC output channels divided into two isolated groups of 4 points, enabling independent voltage source control per bank.
- High Current Output Performance: Provides up to 1.0 A per point at 30°C, offering higher power output per channel compared to high-density modules.
- Robust Surge Capability: Supports inrush surge currents up to 10 A per point for 25 ms, allowing safe switching of heavy inductive loads.
- Optical Noise Isolation & Status LEDs: Integrates optical coupling between backplane logic and field circuitry, complete with front-panel status LEDs for real-time channel diagnostics.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Brand / Manufacturer | Allen-Bradley / Rockwell Automation |
| Catalog Part Number | 1746-OA8 |
| Product Series | SLC 500 Modular I/O Series |
| Module Type | Discrete AC Output Module |
| Number of Outputs | 8 AC outputs (2 groups of 4 channels) |
| Nominal Output Voltage | 120 / 240 V AC (47 to 63 Hz) |
| Operating Voltage Range | 85 to 264 V AC |
| Continuous Current per Point | 1.00 A @ 30°C (86°F) | 0.50 A @ 60°C (140°F) |
| Continuous Current per Module | 8.0 A max @ 30°C (86°F) | 4.0 A max @ 60°C (140°F) |
| Surge Current per Point | 10.0 A maximum for 25 ms |
| On-State Voltage Drop | 1.5 V AC max @ 1.0 A load current |
| Signal Delay Times | OFF-to-ON: 1 ms | ON-to-OFF: 11.0 ms |
| Backplane Current Consumption | 185 mA @ 5 V DC |
| Slot Width & Mounting | Single slot / SLC 500 Chassis Mount |
| Estimated Shipping Weight | Approx. 0.35 kg (0.77 lbs) |
Installation & Handling Guidelines
- Chassis Power Isolation: Always turn off power to the SLC 500 rack prior to inserting or removing the 1746-OA8 module to avoid damaging backplane connections.
- Thermal Considerations: Observe temperature derating rules, limiting individual point currents to 0.50 A if operating temperatures reach 60°C (140°F).
- Wiring Isolation: Route AC output field wiring separately from low-voltage DC signals and sensor wiring to minimize noise coupling within control enclosures.
Technical FAQs
Q1: What is the continuous current rating per point for the Allen-Bradley 1746-OA8 module?
A1: It supports 1.0 A per point at 30°C, derating to 0.5 A per point at 60°C.
Q2: How much backplane current does the 1746-OA8 module consume?
A2: The module consumes 185 mA at 5 V DC from the chassis backplane power supply.
Q3: How are the output points grouped on the 1746-OA8 module?
A3: The 8 output channels are organized into two isolated groups of 4 channels each.
Goşmaça spesifikasiýalar
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
How Does TSI Integration Reduce Turbine False Trip Risks?
This article examines data-driven turbine safety monitoring and mechanical fault diagnosis within industrial automati...
-
Can turn-key automation services really cut plant downtime by 47%?
This article examines how fragmented PLC, DCS, TSI, and power-protection systems drive hidden operational losses in p...
-
Is Your Manufacturing Execution Still Stuck in Open-Loop Mode?
This article examines how closed-loop automated control resolves the critical disconnect between production planning ...
-
Can Predictive Analytics Cut Factory Automation Downtime?
This article examines how predictive abnormality pre-judgment technology addresses the economic burden of reactive fa...
-
Is Full PLC Replacement Best for Brown-Field Automation?
This technical article analyzes the hidden costs of full-scale PLC and DCS hardware replacement in brown-field plants...
-
Is Your DCS Logic Tuning Ready for Real-World Production Loads?
This article examines the critical role of physical on-site commissioning and logic tuning in industrial automation, ...