Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:2094-BC04-M03-S
Allen-Bradley 2094-BC04-M03-S Servo Drive Module 360-480V AC STO
Manufacturer: Allen-Bradley
Product No.: 2094-BC04-M03-S
Product Type: Servo Drives
Product Origin: USA
Payment:T/T, Western Union
Weight: 9600g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
Allen-Bradley Kinetix 6000 Integrated Axis Module 2094-BC04-M03-S
The 2094-BC04-M03-S is a Kinetix 6000 Integrated Axis Power Module (IAM) from Allen-Bradley (Rockwell Automation). This 400V class module operates on 324-528V AC 3-phase input (360-480V nominal) with 47-63 Hz frequency.
Core Specifications
- Manufacturer: Rockwell Automation
- Brand: Allen-Bradley
- Series: Kinetix 6000
- Model: 2094-BC04-M03-S
- Product Type: Integrated Axis Module (IAM) - 400V Class
- Module Location: Leftmost of the Power Rail
- AC Input Voltage: 324-528V rms 3-Phase (360-480V nominal)
- AC Input Frequency: 47-63 Hz
- AC Input Current (nom rms): 44.0 A
- AC Input Current (max inrush 0-pk): 31.1 A
- DC Input Voltage (Common Bus Follower): 458-747V
- DC Input Current (Common Bus Follower): 41.5 A
- Efficiency: 97%
Converter & Inverter Sections
- Converter Section Output: 28 kW
- Inverter Section Output Current: 30 A
Control Performance
- Bandwidth: Velocity Loop: 500 Hz | Current Loop: 1300 Hz
- PWM Frequency: 4 kHz
Internal Shunt Specifications
- Internal Shunt Continuous Power: 200 W
- Internal Shunt Peak Power: 22.5 kW
- Internal Shunt Resistor: 28.75 Ohms
Output Power Dissipation by Loading
- 20% Loading: 53 W
- 40% Loading: 72 W
- 60% Loading: 93 W
- 80% Loading: 116 W
- 100% Loading: 142 W
- Power Dissipation Range: 94-255 W
Safety Features
- Safe Torque-Off (STO) functionality with 200V/400V-class AC input power
Series Variants & Peak Current Ratings
- Series A: 150% peak current rating
- Series B & C: 250% peak current rating with peak enhancement feature
Physical Specifications
- Weight: 21.1 lbs (9.60 kg)
- Operating Temperature: 32-122°F (0-50°C)
Separately Ordered Connector Kits
- Input/Output Interfaces, Safety & Auxiliary Feedback: 2090-K6CK-D44M and 2090-K6CK-D44S0
- Motor Feedback: 2090-K6CK-D15M
Key Features
- Integrated converter and inverter in a single module
- 28 kW converter output for demanding applications
- 30A inverter output current
- Safe Torque-Off for enhanced operator safety
- 97% efficiency for reduced energy costs
- Provides Kinetix Integrated Motion solution for drive, motor, and actuator applications
- Peak enhancement feature available on Series B and C 400V-class modules
Package Includes
- 1x Allen-Bradley 2094-BC04-M03-S Kinetix 6000 Integrated Axis Module
- 1x wiring plug connector set (MP and BC)
- 1x installation documentation
Technical Documentation
📥 Download Product Datasheet PDF
FAQ
Q1: What is the power rating of the 2094-BC04-M03-S Integrated Axis Module?
It features a 28 kW converter section and 30A inverter output current, weighing 9.60 kg (21.1 lbs).
Q2: Where must this module be installed in the power rail?
The IAM must be installed at the leftmost position of the power rail, with all other modules mounted to the right.
Q3: What are the differences between series variants?
Series A has 150% peak current rating, while Series B and C feature 250% peak current ratings with peak enhancement capability.
Goşmaça spesifikasiýalar
- Çal
- Ak
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
Can a Multi-Vendor PM Checklist Cut PLC Downtime?
This article presents a standardized annual preventive maintenance checklist for mixed-vendor industrial control envi...
-
Why Emerson Hot Redundancy Retrofit Slashes Downtime by 96%?
Process plants relying on GE Fanuc single PLCs face 47% of unplanned outages from controller failure, costing $38,000...
-
Cut Migration Engineering Hours by 60% – How Does It Work?
This technical guide examines the operational risks and engineering overhead of maintaining separate GE Proficy HMI a...
-
Is Your 1756 Supply Chain Risking Production?
Counterfeit 1756 modules cause 68% of unplanned PLC downtime. This guide covers a four-step verification method, real...
-
Why Do 72% of Analog Loop Failures Trace Back to Wiring Errors?
This technical guide presents field-verified wiring protocols for integrating Emerson Rosemount 4–20mA HART transmitt...
-
GE Fanuc VersaMax: Did It Replace Obsolete ABB AC500-ECO?
This technical case study details a complete control system retrofit for a 1200m³/day municipal water plant. Our team...