Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:1734-IM2
Allen-Bradley | 2 Input AC Module | 220V AC 1734-IM2
Manufacturer: Allen-Bradley
Product No.: 1734-IM2
Product Type: Digital Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 30g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
Product Overview
The Allen-Bradley 1734-IM2 is a POINT I/O 1734 series digital AC input module with 2 inputs rated at 220V AC. It ranks among the smallest input modules in the series due to its compact 2-point design. Weighing approximately 30.9 g (1.09 oz), this open-style module mounts on a DIN rail and requires the mounting base keyswitch rotated to position 8.
Technical Configuration
This module provides 2 non-isolated sink inputs in a single group of 2. It accepts an external AC power supply of 220V AC at 60 Hz with an input voltage range of 159 to 264V AC at 47 to 63 Hz. Status indicators allow real-time monitoring of input states. The module installs on 1734-TB, 1734-TBS, 1734-TOP, or 1734-TOPS terminal base units and accepts 14 to 22 AWG solid or stranded copper wire rated at 75°C.
Technical Specifications
| Parameter | Value |
|---|---|
| Manufacturer | Rockwell Automation |
| Brand | Allen-Bradley |
| Part Number | 1734-IM2 |
| Series | POINT I/O |
| Module Type | Digital AC Input Module |
| Inputs | 2 (1 group of 2), non-isolated sink |
| Input Voltage | 220V AC nominal |
| Input Voltage Range | 159-264V AC at 47-63 Hz |
| On-State Current | 6.2 mA @ 159V AC; 8.5 mA @ 220V AC; 10.2 mA @ 264V AC |
| Off-State Voltage/Current | Max 43V AC / max 2.9 mA |
| Nominal Input Impedance | 22.3 kΩ |
| POINTBus Current | 75 mA at 5V DC |
| Power Dissipation | Max 0.48 W at 264V AC |
| Thermal Dissipation | Max 1.63 BTU/hour at 264V AC |
| Isolation Voltage | 240V continuous (field to system) |
| Key Switch Position | 8 |
| Compatible Terminal Bases | 1734-TB, 1734-TBS, 1734-TOP, 1734-TOPS |
| Wire Size | 14-22 AWG copper, 75°C rated |
| Dimensions | 2.21 x 0.47 x 2.97 in |
| Weight | 30.9 g (1.09 oz) |
| Operating Temperature | -20 to 55°C |
| Relative Humidity | 5-95% non-condensing |
| Operating Vibration | 5 g at 10-500 Hz |
| Operating Shock | 30 g |
Installation Guide
Rotate the terminal base keyswitch to position 8 before mounting the module. Install on a DIN rail using a 1734-TB, 1734-TBS, 1734-TOP, or 1734-TOPS terminal base unit. Wire field connections with 14 to 22 AWG solid or stranded copper wire rated at 75°C. Verify the external AC supply delivers 220V AC at 60 Hz within the 159-264V AC input range. Confirm the 240V continuous isolation between field side and system before energizing the module.
Engineering Advantages
This module's 2-point design provides a space-efficient solution for applications needing only minimal AC input channels. The wide 159-264V AC input range tolerates supply fluctuations common in industrial power systems. 240V continuous isolation between field side and system protects the POINT bus from hazardous voltages. Status indicators enable immediate visual confirmation of input states without programming tools. The 22.3 kΩ input impedance and low 2.9 mA off-state current reduce leakage concerns in AC circuits.
Technical FAQs
Q1: How many inputs does the 1734-IM2 provide?
A1: This module provides 2 non-isolated sink inputs in one group of 2, rated at 220V AC nominal with a 159-264V AC range.
Q2: What key switch position is required for this module?
A2: The mounting base keyswitch must be rotated to position 8 before installing the 1734-IM2.
Q3: What terminal base units are compatible?
A3: Compatible terminal bases include 1734-TB, 1734-TBS, 1734-TOP, and 1734-TOPS, using 14 to 22 AWG copper wire rated at 75°C.
Goşmaça spesifikasiýalar
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
When Should You Replace a Yokogawa Analog IO Card?
This article breaks down Yokogawa analog AI/AO card calibration tolerances, drift aging benchmarks, and formal replac...
-
What Performance Gains Does S7-1500 Offer Over Legacy S7 PLCs?
Legacy Siemens S7-300 and S7-400 PLCs face spare-part shortages, rising failure rates and limited network capability,...
-
What Logic Changes Cut SIS False Trips by 94%?
This article examines practical logic modification and parameter tuning methods for ABB 800xA HI SIL3 safety ins...
-
Why Do FTE Redundancy Failovers Lock Up in DCS?
Honeywell FTE delivers sub-500 ms failover for Experion PKS, yet field records show 38% of outages stem from installa...
-
How Does the Bently Nevada 3500/42M Vibration Module Drift?
This technical guide examines the Bently Nevada 3500/42M vibration module within industrial automation architect...
-
What Causes IC694MDL Fault Codes in GE RX3i PLC Systems?
This guide explains GE RX3i IC694MDL discrete I/O fault codes, key electrical parameters, ESD and torque requirements...