Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:1794-OF8IH
Allen-Bradley 1794-OF8IH Flex I/O 4-20mA HART Module
Manufacturer: Allen-Bradley
Product No.: 1794-OF8IH
Product Type: Analog Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 90g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
Product Overview
The Allen-Bradley 1794-OF8IH is a Flex I/O isolated analog output module with HART capability. Weighing approximately 90 g, it provides 8 single ended isolated outputs configurable for 0-20 mA and 4-20 mA with 16 bit resolution for precise control of HART enabled field devices.
Key Features
8 isolated analog output channels configurable for 0-20 mA and 4-20 mA. 16 bit unipolar resolution with 0.305 µA per count. HART pass through messaging with 1 or 2 connections supporting 8 queues per connection. Lead breakage detection plus overrange and underrange alarms. Factory calibrated, no external power supply required. Keyswitch position 4 for terminal base installation. Lightweight 90 g design. 6 WORD HART data register with IEEE 754 single precision floating point.
Technical Specifications
| Manufacturer | Rockwell Automation |
| Brand | Allen-Bradley |
| Part Number | 1794-OF8IH |
| Series | Flex I/O 1794 |
| Module Type | Isolated Analog Output HART Module |
| Number of Outputs | 8 Isolated |
| Output Signals | 0-20 mA, 4-20 mA |
| Resolution | 16 Bit Unipolar (0.305 µA/count) |
| Conversion Method | 16 Bit Digital to Analog Converter |
| Conversion Rate | 10 ms |
| Settling Time | 70 ms |
| Data Formats | Engineering Units, Percent of Full Scale, RAW/Proportional Count |
| HART Support | Pass Through Messaging |
| Compatible Terminal Bases | 1794-TB3, 1794-TB3S |
| Flexbus Current | 80 mA at 5 V DC |
| Power Dissipation | 5.0 W at 24 V DC Max |
| Thermal Dissipation | 17.06 BTU/hr at 24 V DC Max |
| Operating Temperature | 32 to 131°F (0 to 55°C) |
| Weight | Approximately 90 g |
Installation Guide
Install the 1794-OF8IH (approx. 90 g) on a compatible terminal base such as 1794-TB3 or 1794-TB3S. Rotate the keyswitch to position 4 to lock the module in place. No external power supply is required as the module draws 80 mA at 5 V DC from the Flexbus. Configure each channel independently for 0-20 mA or 4-20 mA as required. Wire type depends on the terminal base used. Ensure operating temperature remains between 0 and 55°C.
Engineering Advantages
HART pass through messaging enables communication with smart field devices without additional hardware. 8 isolated outputs prevent ground loops and channel interference. Independent channel configuration eliminates jumpers and switches for faster commissioning. Lead breakage detection and current alarms improve system reliability. Factory calibration eliminates field adjustment. Lightweight 90 g compact 1794 Flex I/O design integrates with existing ControlNet, DeviceNet, and EtherNet/IP networks.
Frequently Asked Questions
Q1: How many outputs does the 1794-OF8IH provide?
A1: It provides 8 isolated analog output channels configurable for 0-20 mA and 4-20 mA.
Q2: Does this module support HART communication?
A2: Yes, it supports HART pass through messaging with up to 2 connections and 8 queues per connection.
Q3: Does this module require an external power supply?
A3: No, it draws power from the Flexbus at 80 mA and 5 V DC.
Goşmaça spesifikasiýalar
- Çal
- Ak
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
Why Do SIL3 Safety Interlocks Still Trip in Industrial Plants?
This article reviews Honeywell Safety Manager SIL3 SIS architecture, wiring and cabinet installation rules, PFDa...
-
How Does Poor Grounding Cause 4-20mA Signal Drift?
This guide explains how MTL signal isolators fail through distortion, drift and EMI in PLC and DCS loops, then d...
-
What Bench Tests Prove a Series 90-30 Module Works?
GE Series90 PLCs remain in service long after factory support ended in 2023, and unverified third-party spares carry ...
-
Is Staged Hot Cutover the Right Path for Legacy DCS Upgrade?
This article explains how continuous process plants migrate Yokogawa CS3000 to CENTUM VP through staged hot cutover, ...
-
How Do You Fix ControlLogix Redundancy Switchover Failures?
This article examines the hidden causes of Allen-Bradley 1756 redundant CPU switchover failures on oil and gas ski...
-
Why Is INFI90 End-of-Life a Growing Risk for Power DCS?
This article examines ABB Bailey INFI90 end-of-life risks in power DCS environments and presents a three-tier moderni...