Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:1794-OA8I
Allen-Bradley 1794-OA8I Digital Output Module 120VAC
Manufacturer: Allen-Bradley
Product No.: 1794-OA8I
Product Type: Digital Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 150g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
Allen-Bradley 1794-OA8I Flex I/O AC Isolated Digital Output Module
Allen-Bradley 1794-OA8I | Flex I/O AC digital output module with 8 individually isolated output channels. Operates at 120V AC nominal voltage with 4.0 A output current rating. Designed for distributed I/O systems connecting actuators triggered by process logic. Weight: approximately 0.15 kg (0.33 lbs).
Key Features
8 individually isolated outputs. 120V AC nominal output voltage. 4.0 A output current rating (500 mA per output). Minimum on-state current 5 mA per output. Maximum on-state voltage drop 1.0V at 0.5 A. Maximum off-state leakage 2.25 mA. 120V continuous isolation (channel-to-channel and field-to-backplane). 1250V AC for 60 seconds (channel-to-channel). 80 mA Flexbus current at 5V DC. Yellow LED indicator per active output. Recommended fusing 1.6 A, 250V AC slow-blow.
Technical Specifications
| Manufacturer | Rockwell Automation |
| Brand | Allen-Bradley |
| Part Number | 1794-OA8I |
| Product Type | Flex I/O Digital Output Module |
| Outputs | 8 (Isolated) |
| Output Voltage (Nominal) | 120V AC |
| Output Current Rating | 4.0 A (500 mA per output) |
| On-State Current (Min) | 5 mA per output |
| On-State Voltage Drop | 1.0V max @ 0.5 A |
| Off-State Leakage Current | 2.25 mA max |
| Isolation Voltage (Continuous) | 120V (channel-to-channel, field-to-backplane) |
| Isolation Voltage (60 s) | 1250V AC (channel-to-channel) |
| Flexbus Current | 80 mA @ 5V DC |
| Power Dissipation | 4.1 W @ 0.5 A; 6.3 W @ 1 A |
| Thermal Dissipation | 14.0 BTU/hr @ 0.5 A |
| Recommended Fusing | 1.6 A, 250V AC slow-blow |
| Dimensions (H x W x D) | 94 x 94 x 69 mm |
| Operating Temperature | -20°C to +55°C |
| Weight | Approx. 0.15 kg (0.33 lbs) |
| UPC | 10612598179951 |
Compatible Terminal Base Units
1794-TB3S, 1794-TB2, 1794-TB3, 1794-TBN, and 1794-TBNF. Insert module into base with keyswitch set to Position 8. Connect individual isolated output to even-number terminals and 120V AC power to adjacent odd-number terminals. Connect isolated 120V AC common terminals to each output device.
Installation Notes
Install in compatible terminal base with keyswitch set to Position 8. Wire isolated outputs to even-number terminals, 120V AC power to adjacent odd-number terminals. Connect individual isolated commons to each output device. Use recommended 1.6 A, 250V AC slow-blow fuses. Verify yellow LED indicators per active output during commissioning. Operate within -20°C to +55°C ambient temperature.
Engineering Advantages
Individually isolated outputs allow each channel to switch independent circuits, simplifying mixed-voltage installations and fault isolation. 1250V AC channel-to-channel isolation protects sensitive equipment. 500 mA per output supports direct load switching without interposing relays. Yellow LED per channel simplifies field diagnostics. Compatible with multiple Flex I/O terminal bases for flexible installation. Modular design enables distributed I/O architecture.
FAQs
Q1: How many outputs does this module provide?
A1: 8 individually isolated AC outputs.
Q2: What is the isolation rating?
A2: 120V continuous (channel-to-channel, field-to-backplane) and 1250V AC for 60 seconds channel-to-channel.
Q3: What fusing is recommended?
A3: 1.6 A, 250V AC slow-blow fuses.
Goşmaça spesifikasiýalar
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
How Does the Bently Nevada 3500/42M Vibration Module Drift?
This technical guide examines the Bently Nevada 3500/42M vibration module within industrial automation architect...
-
What Causes IC694MDL Fault Codes in GE RX3i PLC Systems?
This guide explains GE RX3i IC694MDL discrete I/O fault codes, key electrical parameters, ESD and torque requirements...
-
What CFC Rules Cut PCS7 Batch Abort Rates Fast?
This article presents enforceable CFC programming governance rules for Siemens PCS7 DCS batch plants, covering b...
-
What Makes the 1769-L3ER Ideal for Compact Skid Automation?
This guide explains how the Allen-Bradley 1769 CompactLogix L3ER bridges the gap between micro PLCs and large DC...
-
Why Do SIL3 Safety Interlocks Still Trip in Industrial Plants?
This article reviews Honeywell Safety Manager SIL3 SIS architecture, wiring and cabinet installation rules, PFDa...
-
How Does Poor Grounding Cause 4-20mA Signal Drift?
This guide explains how MTL signal isolators fail through distortion, drift and EMI in PLC and DCS loops, then d...
