Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:1794-OA8
Allen-Bradley 1794-OA8 Flex I/O AC Output Module
Manufacturer: Allen-Bradley
Product No.: 1794-OA8
Product Type: AC Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 150g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
Allen-Bradley 1794-OA8 Flex I/O AC Digital Output Module
Allen-Bradley 1794-OA8 | Flex I/O AC digital output module with 8 non-isolated output channels. Operates at 120V AC nominal voltage with 4.0 A output current rating. Designed for all non-hazardous industrial environments and Class 1, Division 2 areas. Weight: approximately 0.15 kg (0.33 lbs).
Key Features
8 non-isolated outputs in one group. 120V AC nominal output voltage, 85-132V AC range. 4.0 A output current rating. Minimum on-state current 5 mA per output. Maximum on-state voltage drop 1.0V at 0.5 A. Maximum off-state leakage 2.25 mA. 120V continuous isolation voltage. 80 mA Flexbus current at 5V DC. Surge current 7 A for 40 ms, repeatable every 8 seconds. Output signal delay max 1/2 cycle. Diagnostics for field devices, wiring, and power supply. Lightweight at 0.15 kg (0.33 lbs).
Technical Specifications
| Manufacturer | Rockwell Automation |
| Brand | Allen-Bradley |
| Part Number | 1794-OA8 |
| Product Type | Flex I/O Digital Output Module |
| Outputs | 8 (Non-isolated) |
| Output Voltage (Nominal) | 120V AC |
| Output Voltage Range | 85-132V AC |
| Output Current Rating | 4.0 A |
| On-State Current (Min) | 5 mA per output |
| On-State Voltage Drop | 1.0V max @ 0.5 A |
| Off-State Leakage Current | 2.25 mA max |
| Isolation Voltage | 120V continuous |
| Flexbus Current | 80 mA @ 5V DC |
| Surge Current | 7 A for 40 ms, repeatable every 8 s |
| Signal Delay (ON/OFF) | Max 1/2 cycle |
| Power Dissipation | 4.1 W @ 0.5 A; 6.3 W @ 0.75 A and 1 A |
| Thermal Dissipation | 14.0 BTU/hr @ 0.5 A; 21.2 BTU/hr @ 0.75 A; 21.4 BTU/hr @ 1 A |
| Weight | Approx. 0.15 kg (0.33 lbs) |
| UPC | 10612598137845 |
Current Derating by Temperature
| 55°C | 500 mA per output |
| 35°C | 750 mA per output |
| 30°C | 500 mA on 4 outputs; 1 A on 4 non-adjacent outputs |
Compatible Terminal Base Units
1794-TBNK, 1794-TBKD, 1794-TB3K, 1794-TBNFK, 1794-TB3SK, 1794-TBNF, 1794-TB3, 1794-TB2, 1794-TB3S, and 1794-TBN. Auxiliary terminal strips are required when using the 1794-TBN base unit.
Installation Notes
Install directly on compatible Flex I/O terminal base units. Use auxiliary terminal strips when mounting on the 1794-TBN base. Observe current derating based on ambient temperature: 500 mA per output at 55°C, 750 mA at 35°C. Verify off-state leakage does not affect connected loads. Ensure proper grounding per Allen-Bradley wiring guidelines. Suitable for non-hazardous and Class 1 Division 2 environments.
Engineering Advantages
Integrated diagnostics identify faults in field devices, wiring, and power supply, reducing commissioning and troubleshooting time. 8 outputs in a single Flex I/O module maximize channel density. High 4.0 A module rating handles demanding AC loads directly. Surge current capability of 7 A supports inductive load switching. Wide 85-132V AC range accommodates supply variations. Modular Flex I/O design enables flexible system expansion.
FAQs
Q1: How many outputs does this module provide?
A1: 8 non-isolated AC outputs in a single group.
Q2: What is the output voltage range?
A2: 85-132V AC, with a nominal rating of 120V AC.
Q3: What is the current rating at different temperatures?
A3: 500 mA per output at 55°C, 750 mA per output at 35°C, and 1 A on 4 non-adjacent outputs at 30°C.
Goşmaça spesifikasiýalar
- Çal
- Ak
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
How Does Honeywell APC Improve Refinery Yield?
Honeywell APC applies model predictive control to refinery and chemical units, reducing process variability by 30% to...
-
How Can Bently Nevada Vibration Trends Predict Machine Failures?
This article explains how maintenance teams convert raw Bently Nevada TSI vibration trends into actionable predictive...
-
How Does ABB Redundant Control Cut Downtime?
ABB redundant controller architecture removes single point of failure risk in DCS and PLC systems through hot standby...
-
How Does Honeywell Universal Transmitter Improve DCS Gas Safety?
This article examines field integration practices for Honeywell Universal Transmitters within DCS architectures at ch...
-
How Does GE Proficy HMI Design Cut Operator Response Time?
This article explains how field-proven GE Proficy HMI design principles, including tiered navigation, ISA 101 alarm c...
-
How Does ABB Cabinet FAT Cut Site Commissioning Risk?
This article explains how standardized ABB control cabinet assembly and factory acceptance testing reduce industrial ...