Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:1788-CN2DN
Allen-Bradley 1788-CN2DN ControlNet DeviceNet Linking Device
Manufacturer: Allen-Bradley
Product No.: 1788-CN2DN
Product Type: Linking Device
Product Origin: USA
Payment:T/T, Western Union
Weight: 450g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The Allen-Bradley 1788-CN2DN is a high-performance linking device engineered to bridge communications between ControlNet and DeviceNet networks. This intelligent gateway allows a ControlNet-based controller to seamlessly access, configure, and control I/O devices on a DeviceNet network. By acting as a transparent proxy, the 1788-CN2DN reduces the complexity of multi-layered network architectures, enabling real-time data exchange across different protocols. Its robust, open-style design is tailored for industrial environments where high-speed synchronization and reliability are critical.
Technical Configuration
The 1788-CN2DN is optimized for high-speed industrial data routing:
- Protocol Conversion: Facilitates bi-directional data flow between ControlNet (RG6 coaxial) and DeviceNet (0.52 mm² wiring).
- Power System: Requires a stable 24V DC input with a typical low power consumption of 5W.
- Status Monitoring: Equipped with a comprehensive array of LED indicators for Module Status, Network Status, and Linking Activity.
- Rugged Construction: Features a zinc-plated, chromate-passivated steel DIN rail mounting system to resist corrosion and mechanical stress.
- High Survivability: Rated for an operating shock of 30G and an isolation voltage of 30V.
Technical Specifications
| Parameter | Specification |
|---|---|
| Input Power | 24V DC |
| ControlNet Media | RG6 Coaxial Cable |
| DeviceNet Media | 0.52 mm² (20 AWG) Wire |
| Operating Temperature | 0°C to 60°C (32°F to 140°F) |
| Isolation Voltage | 30V (Continuous) |
| Typical Net Weight | Approximately 0.45 kg (0.99 lbs) |
Installation Guide
Proper installation of the Allen-Bradley 1788-CN2DN is vital for maintaining network integrity. The device should be mounted on a grounded DIN rail within a protected enclosure, as it is an open-style module.
Network Integration
When connecting the ControlNet side, ensure the RG6 connectors are properly crimped and torqued. For the DeviceNet side, use standard 5-pin open style connectors. It is highly recommended to place the linking device as close to the center of the DeviceNet trunk line as possible to minimize signal drop.
Diagnostic LEDs
The LED panel provides instant feedback:
- Module Status: Solid green indicates the device is operational.
- Linking Activity: Flashing indicates data is actively being routed between networks.
- ControlNet A/B: Monitors the health of redundant ControlNet channels.
Engineering Advantages
The 1788-CN2DN is a lightweight yet powerful solution with a net weight of approximately 0.45 kg, making it easy to integrate into existing high-density control panels without significant structural changes. Its support for real-time communication protocols ensures that timing-critical data from DeviceNet sensors reaches the ControlNet master with minimal latency. Furthermore, the 30G shock rating makes it suitable for use in heavy industrial applications where machinery produces constant vibration or physical impacts.
Technical FAQs
Q1: Does this device require a separate node address on both networks?
A1: Yes, the 1788-CN2DN must be assigned a unique ControlNet node address and a DeviceNet MAC ID to be recognized by the respective network scanners.
Q2: Can I use this to bridge two ControlNet networks?
A2: No, this specific model is designed exclusively to bridge ControlNet to DeviceNet. For ControlNet-to-ControlNet bridging, you would require a different gateway module.
Q3: Is the 24V DC power provided by the DeviceNet cable?
A3: While DeviceNet carries power, it is best practice to provide a dedicated 24V DC source to the 1788-CN2DN power terminals to ensure stable operation of the internal linking logic, especially in large networks.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Can DCS Intelligent Regulation Fix Thermal Power Energy Imbalance?
This article explains how intelligent DCS regulation with MPC and cloud-based control solves energy-production imbala...
-
Can Continuous Automation Iteration Cut Factory Costs by 18-25%?
Static industrial control systems create hidden annual cost increases of 18-25%. Phased PLC and DCS program iteration...
-
Can Anti-Interference Hardware End 38% of Automation Downtime?
Field data from chemical, wind, and automotive plants proves that industrial hardware with full IEC 61000-4 EMC certi...
-
How Does Full-Lifecycle Management Optimize PLC and DCS Assets?
Traditional industrial asset management relies on manual logging and reactive troubleshooting, causing 15–20% annual ...
-
Can an Integrated Spare Chain Slash Downtime?
Unplanned equipment failures cost Chinese factories ¥636,000 per hour. Traditional cross-border spare procurement tak...
-
Why Do 30% of Automation Upgrades Fail Due to Integration Gaps?
This technical article explains how digital-intelligent fusion overcomes fragmented workshop operations using industr...
