Skip to content
Automation parts, worldwide supply
Skip to product information
1 of 3

SKU:1788-CN2DN

Allen-Bradley 1788-CN2DN ControlNet DeviceNet Linking Device

In stock (11 units), ready to be shipped
  • Manufacturer: Allen-Bradley

  • Product No.: 1788-CN2DN

  • Product Type: Linking Device

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 450g

  • Shipping port: Xiamen

  • Warranty: 12 months

30-Day Return Policy · 12-Month Warranty
  • Fast Delivery
  • 24/7 Support
  • Quality Assurance

Description

Product Overview

The Allen-Bradley 1788-CN2DN is a high-performance linking device engineered to bridge communications between ControlNet and DeviceNet networks. This intelligent gateway allows a ControlNet-based controller to seamlessly access, configure, and control I/O devices on a DeviceNet network. By acting as a transparent proxy, the 1788-CN2DN reduces the complexity of multi-layered network architectures, enabling real-time data exchange across different protocols. Its robust, open-style design is tailored for industrial environments where high-speed synchronization and reliability are critical.

Technical Configuration

The 1788-CN2DN is optimized for high-speed industrial data routing:

  • Protocol Conversion: Facilitates bi-directional data flow between ControlNet (RG6 coaxial) and DeviceNet (0.52 mm² wiring).
  • Power System: Requires a stable 24V DC input with a typical low power consumption of 5W.
  • Status Monitoring: Equipped with a comprehensive array of LED indicators for Module Status, Network Status, and Linking Activity.
  • Rugged Construction: Features a zinc-plated, chromate-passivated steel DIN rail mounting system to resist corrosion and mechanical stress.
  • High Survivability: Rated for an operating shock of 30G and an isolation voltage of 30V.

Technical Specifications

Parameter Specification
Input Power 24V DC
ControlNet Media RG6 Coaxial Cable
DeviceNet Media 0.52 mm² (20 AWG) Wire
Operating Temperature 0°C to 60°C (32°F to 140°F)
Isolation Voltage 30V (Continuous)
Typical Net Weight Approximately 0.45 kg (0.99 lbs)

Installation Guide

Proper installation of the Allen-Bradley 1788-CN2DN is vital for maintaining network integrity. The device should be mounted on a grounded DIN rail within a protected enclosure, as it is an open-style module.

Network Integration

When connecting the ControlNet side, ensure the RG6 connectors are properly crimped and torqued. For the DeviceNet side, use standard 5-pin open style connectors. It is highly recommended to place the linking device as close to the center of the DeviceNet trunk line as possible to minimize signal drop.

Diagnostic LEDs

The LED panel provides instant feedback:

  • Module Status: Solid green indicates the device is operational.
  • Linking Activity: Flashing indicates data is actively being routed between networks.
  • ControlNet A/B: Monitors the health of redundant ControlNet channels.

Engineering Advantages

The 1788-CN2DN is a lightweight yet powerful solution with a net weight of approximately 0.45 kg, making it easy to integrate into existing high-density control panels without significant structural changes. Its support for real-time communication protocols ensures that timing-critical data from DeviceNet sensors reaches the ControlNet master with minimal latency. Furthermore, the 30G shock rating makes it suitable for use in heavy industrial applications where machinery produces constant vibration or physical impacts.

Technical FAQs

Q1: Does this device require a separate node address on both networks?
A1: Yes, the 1788-CN2DN must be assigned a unique ControlNet node address and a DeviceNet MAC ID to be recognized by the respective network scanners.

Q2: Can I use this to bridge two ControlNet networks?
A2: No, this specific model is designed exclusively to bridge ControlNet to DeviceNet. For ControlNet-to-ControlNet bridging, you would require a different gateway module.

Q3: Is the 24V DC power provided by the DeviceNet cable?
A3: While DeviceNet carries power, it is best practice to provide a dedicated 24V DC source to the 1788-CN2DN power terminals to ensure stable operation of the internal linking logic, especially in large networks.

🏷️ Tags: Linking Device

Scalar (V/f)

Vector

AC-powered

  • Confirm the exact model, part number, and specifications before ordering.
  • Ensure compatibility with your current machinery or control systems.
  • Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
  • Review delivery options, lead times, and shipping requirements.
  • Follow manufacturer instructions and best practices during installation.

In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.

Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.

For more details, please review our Shipping & Return Policy.

View Product Details

ENSURE RELIABLE MACHINERY PERFORMANCE

Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.