Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:1746-IM4
Allen-Bradley 1746-IM4 SLC 500 | 4-Point AC Input Module 240V
Manufacturer: Allen-Bradley
Product No.: 1746-IM4
Product Type: AC Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 320g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
Product Overview
The Allen-Bradley 1746-IM4 is a 4-channel Digital AC Input Module for the SLC 500 PLC system. It accepts 170-265V AC signals from field devices such as limit switches, pushbuttons, and proximity sensors. This module mounts directly into the 1746 I/O chassis, providing reliable AC input monitoring for general-purpose industrial control applications.
Core Functionality
The 1746-IM4 converts 200-240V AC field signals into logic-level inputs for the SLC 500 processor. Each of the four input channels features a nominal input current of 12mA at 240V AC. Signal delay times are 35ms for ON transitions and 45ms for OFF transitions. Off-state leakage current is limited to 2.0mA maximum, preventing false triggering. Circuit isolation is tested at 1500V AC between the backplane and I/O, protecting the control system from field-side faults.
Technical Specifications
| Parameter | Value |
| Part Number | 1746-IM4 |
| Series | SLC 500 |
| Module Type | Digital AC Input Module |
| Inputs | 4 |
| Voltage Range | 170-265V AC (47-63 Hz) |
| Nominal Input Current | 12mA @ 240V AC |
| Backplane Current (5V DC) | 35 mA |
| Backplane Current (24V DC) | 0 A |
| ON Signal Delay | 35 ms (max) |
| OFF Signal Delay | 45 ms (max) |
| Off-State Leakage Current | 2.0 mA (max) |
| Off-State Voltage Loss | 50V AC (max) |
| Surge Current per Point | 1.6A (500µs duration) |
| Power Dissipation | 1.6W |
| Isolation (Backplane to I/O) | 1500V AC |
| Weight | Approx. 0.32 kg (0.7 lbs) |
| Operating Temperature | 0°C to 60°C (32°F to 140°F) |
| Storage Temperature | -40°C to 85°C (-40°F to 185°F) |
| Humidity | 5-95% (non-condensing) |
| Shock Rating | 30G |
| Vibration Rating | 2.5G (57-500 Hz) |
| Certifications | UL-A196, CSA, C-UL (hazardous locations) |
| Noise Immunity | NEMA ICS 2-230 |
Installation Guide
Install the 1746-IM4 in any available slot of the SLC 500 1746 I/O chassis. Ensure the chassis is powered off before insertion. Align the module with the card guides and push firmly until the connector seats fully with the backplane. Secure the module with the retaining screw. Connect field wiring using 1746-HT or 1746-HCA I/O connection cables. Observe polarity: AC inputs are not polarity-sensitive but maintain consistent wiring practices for troubleshooting.
Engineering Advantages
The 1746-IM4 provides reliable AC input monitoring with 1500V AC isolation, protecting the SLC 500 backplane from field-side transients. The 35ms ON and 45ms OFF delays filter contact bounce and electrical noise, ensuring stable input states. Off-state leakage current of just 2.0mA prevents false triggering from residual current in long cable runs. The module is rated for 30G shock and 2.5G vibration, making it suitable for heavy machinery environments. UL and CSA certifications allow installation in hazardous locations. The lightweight design at approximately 0.32 kg (0.7 lbs) simplifies installation and reduces chassis loading.
Technical FAQs
Q1: Can the 1746-IM4 accept 120V AC inputs?
A1: No. The 1746-IM4 is designed for 170-265V AC (200-240V AC nominal). For 120V AC inputs, use the 1746-IA4 or 1746-IA8 module instead.
Q2: What is the purpose of the 35ms ON delay?
A2: The ON delay filters electrical noise and contact bounce from mechanical switches, preventing false transitions and ensuring stable processor input states.
Q3: Is the 1746-IM4 compatible with 1746 chassis of any series?
A3: Yes. The 1746-IM4 works with all SLC 500 1746-series chassis, including the 1746-A4, A7, A10, and A13 models.
Goşmaça spesifikasiýalar
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
How Does TSI Integration Reduce Turbine False Trip Risks?
This article examines data-driven turbine safety monitoring and mechanical fault diagnosis within industrial automati...
-
Can turn-key automation services really cut plant downtime by 47%?
This article examines how fragmented PLC, DCS, TSI, and power-protection systems drive hidden operational losses in p...
-
Is Your Manufacturing Execution Still Stuck in Open-Loop Mode?
This article examines how closed-loop automated control resolves the critical disconnect between production planning ...
-
Can Predictive Analytics Cut Factory Automation Downtime?
This article examines how predictive abnormality pre-judgment technology addresses the economic burden of reactive fa...
-
Is Full PLC Replacement Best for Brown-Field Automation?
This technical article analyzes the hidden costs of full-scale PLC and DCS hardware replacement in brown-field plants...
-
Is Your DCS Logic Tuning Ready for Real-World Production Loads?
This article examines the critical role of physical on-site commissioning and logic tuning in industrial automation, ...