Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:1734-IK
Allen-Bradley 1734-IK | POINT I/O Incremental Encoder Module
Manufacturer: Allen-Bradley
Product No.: 1734-IK
Product Type: Encoder Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 36g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
Product Overview
The Allen-Bradley 1734-IK is a POINT I/O incremental encoder module with 1 counter input. It accepts 15-24V DC input voltage with 6.1 mA current at 15V DC and 10.2 mA at 24V DC. Weighing 0.08 pounds, this open-style module processes frequencies up to 1 MHz and returns counts as a 24-bit binary number in a 32-bit long word. The key switch position is 2 with wiring category 1 on all signal ports.
Technical Configuration
This module provides one input group with A/A, B/B, and Z/Z returns for differential or single-ended encoder feedback. It receives signals from pulse generators, differential or single-ended encoders, and mechanical limit switches. Five status indicators show module state, network status, and A, B, and Z input states. The module mounts on a DIN rail and is compatible with 1734-TB, 1734-TBS, 1734-TB3, or 1734-TB3S wiring base assemblies using 22 to 14 AWG copper wire.
Technical Specifications
| Parameter | Value |
|---|---|
| Manufacturer | Rockwell Automation |
| Brand | Allen-Bradley |
| Part Number | 1734-IK |
| Series | POINT I/O |
| Module Type | Incremental Encoder Module |
| Counter | 1 |
| Input Voltage | 15-24V DC (nominal 24V DC) |
| Input Current | 6.1 mA @ 15V DC; 10.2 mA @ 24V DC |
| Max Frequency | 1 MHz |
| Count Format | 24-bit binary (0-16,777,215) in 32-bit long word |
| Off-State Current/Voltage | ≤ 0.250 mA / ≤ 1.8V DC |
| On-State Current/Voltage | ≥ 5 mA / ≤ 12.5V DC |
| Max POINT Bus Current | 160 mA |
| Max Power Dissipation | 1.5 W at rated load |
| Max Thermal Dissipation | 5.1 BTU/hour at rated load |
| Key Switch Position | 2 |
| Wiring Category | 1 |
| Status Indicators | 5 LEDs (module, network, A, B, Z) |
| Enclosure Type | None (Open-Style) |
| Dimensions | 2.21 x 0.47 x 2.97 in |
| Weight | 0.08 lbs |
| Operating Temperature | -20 to 55°C |
| Relative Humidity | 5-95% non-condensing |
| Operating Vibration | 5 g at 10-500 Hz |
Installation Guide
Mount the 1734-IK on a DIN rail using a compatible 1734-TB, 1734-TBS, 1734-TB3, or 1734-TB3S wiring base assembly. Wire connections with 22 to 14 AWG stranded or solid copper wire. No external DC power supply is required for operation. Verify input signals from differential or single-ended encoders, pulse generators, or mechanical limit switches connect to the A/A, B/B, and Z/Z returns. Confirm key switch position 2 and wiring category 1 requirements during commissioning.
Engineering Advantages
This module processes encoder frequencies up to 1 MHz, supporting high-speed motion and counting applications. The 24-bit binary count resolution enables precise position tracking across 16,777,215 counts. Five LED indicators provide immediate visibility into module, network, and input states for rapid troubleshooting. Compatibility with both differential and single-ended encoders plus mechanical limit switches offers flexible field device integration. The open-style design eliminates external DC power supply requirements, simplifying cabinet wiring.
Technical FAQs
Q1: What encoder types does the 1734-IK support?
A1: This module accepts feedback from differential or single-ended encoders and pulse generators, plus mechanical limit switches, with A/A, B/B, and Z/Z input returns.
Q2: What is the maximum input frequency?
A2: The 1734-IK processes frequencies up to 1 MHz and returns counts as a 24-bit binary number in a 32-bit long word.
Q3: What wiring base assemblies are compatible?
A3: Compatible wiring bases include 1734-TB, 1734-TBS, 1734-TB3, and 1734-TB3S, using 22 to 14 AWG copper wire.
Goşmaça spesifikasiýalar
- Gara
- Çal
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
When Should You Replace a Yokogawa Analog IO Card?
This article breaks down Yokogawa analog AI/AO card calibration tolerances, drift aging benchmarks, and formal replac...
-
What Performance Gains Does S7-1500 Offer Over Legacy S7 PLCs?
Legacy Siemens S7-300 and S7-400 PLCs face spare-part shortages, rising failure rates and limited network capability,...
-
What Logic Changes Cut SIS False Trips by 94%?
This article examines practical logic modification and parameter tuning methods for ABB 800xA HI SIL3 safety ins...
-
Why Do FTE Redundancy Failovers Lock Up in DCS?
Honeywell FTE delivers sub-500 ms failover for Experion PKS, yet field records show 38% of outages stem from installa...
-
How Does the Bently Nevada 3500/42M Vibration Module Drift?
This technical guide examines the Bently Nevada 3500/42M vibration module within industrial automation architect...
-
What Causes IC694MDL Fault Codes in GE RX3i PLC Systems?
This guide explains GE RX3i IC694MDL discrete I/O fault codes, key electrical parameters, ESD and torque requirements...