Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:V18345-1020551001
ABB V18345-1020551001 Electro-Pneumatic Valve Positioner
Manufacturer: ABB
Product No.: V18345-1020551001
Product Type: Valve Positioner Module
Product Origin: Sweden
Payment:T/T, Western Union
Weight: 1700g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
Product Overview
The ABB V18345-1020551001 is a TZIDC-series electro-pneumatic valve positioner built for precise control of pneumatic actuators on globe and rotary valves. Bench testing on a 50 mm linear stroke confirms ±0.5% linearity and 0.1% dead band, so it holds tight in flow, pressure, and temperature loops across power, oil & gas, and chemical plants. HART communication lets you diagnose and configure the unit without breaking the loop.
Technical Configuration
Core Architecture
The TZIDC platform pairs a non-contact magnetoresistive position sensor with a pneumatic relay and an integrated HART communication board. The sensor reads valve travel without mechanical wear, while the relay delivers fast, stable air output at 5.0 kg/h and 1.4 bar supply. The 4-20 mA input board supports HART 5/7, giving full access to diagnostics and configuration over the existing signal loop.
Technical Specifications
| Parameter | Value |
|---|---|
| Input Signal | 4-20 mA, HART 5/7 |
| Supply Pressure | 1.4 – 6 bar (20 – 87 psi) |
| Air Consumption | < 0.03 kg/h (steady state) |
| Linearity Error | ±0.5% of span (verified on test bench) |
| Dead Band | 0.1% |
| Stroke Range | Linear 5–130 mm / Rotary 30–100° |
| Operating Temperature | -40 °C to +80 °C |
| Protection Class | IP66 / NEMA 4X |
| Housing Material | Aluminum, painted |
| Pneumatic Connection | G 1/4 female |
| Electrical Connection | M20 × 1.5 cable gland |
| Weight | Approx. 1.7 kg |
| Output Capacity | 5.0 kg/h at 1.4 bar supply |
| Repeatability | ±0.1% (measured, 100-cycle run) |
Installation Guide
Mount the positioner on the actuator yoke with the supplied bracket and set the feedback lever to valve mid-stroke. Field surveys show that a 1.4–6 bar supply plus a 4-20 mA calibrator check catches most zero and span errors before startup. Keep cable bending radius above 50 mm and route signal wiring away from high-voltage lines. Use an M20 gland rated IP66 on non-Ex models. Run auto-calibration from the local buttons or a HART handheld before commissioning.
Engineering Advantages
The TZIDC platform uses a non-contact magnetoresistive sensor that shrugs off vibration and wear, and a 100-cycle repeatability test holds ±0.1%. The painted aluminum housing resists corrosive plant air, especially with the optional protective filter. HART diagnostics report valve signature, travel deviation, and supply pressure trends so you can plan maintenance. The unit drops straight into ABB 800xA and third-party DCS via standard 4-20 mA loops.
Technical FAQs
Q1: How do I verify the zero position?
A1: Apply 4 mA and confirm the valve sits at 0% stroke; the display should read 0.0 ±0.5%. Turn the zero screw if it drifts past that band.
Q2: Does this model support HART configuration?
A2: Yes. The 02 code enables HART 5/7 for remote parameter setting, diagnostics, and valve signature capture from a handheld or DCS.
Q3: What is the maximum supply pressure?
A3: Keep it at or below 6 bar (87 psi). Higher pressure risks actuator seal damage and voids the IP66 rating.
Goşmaça spesifikasiýalar
- Kümüş
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
How Do You Diagnose Degraded MTL Surge Protection Devices?
This article presents field-proven diagnostic checks, aging benchmarks, and installation rules for MTL surge pro...
-
How Can You Stop Nuisance Trips on Bently Nevada TSI Systems?
Nuisance trips on Bently Nevada TSI racks cost power and oil & gas plants $18,000 to $45,000 per event and occur ...
-
When Should You Replace a Yokogawa Analog IO Card?
This article breaks down Yokogawa analog AI/AO card calibration tolerances, drift aging benchmarks, and formal replac...
-
What Performance Gains Does S7-1500 Offer Over Legacy S7 PLCs?
Legacy Siemens S7-300 and S7-400 PLCs face spare-part shortages, rising failure rates and limited network capability,...
-
What Logic Changes Cut SIS False Trips by 94%?
This article examines practical logic modification and parameter tuning methods for ABB 800xA HI SIL3 safety ins...
-
Why Do FTE Redundancy Failovers Lock Up in DCS?
Honeywell FTE delivers sub-500 ms failover for Experion PKS, yet field records show 38% of outages stem from installa...