Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:V18345-1010521001
ABB V18345-1010521001 TZIDC Positioner 4-20mA Double Acting
Manufacturer: ABB
Product No.: V18345-1010521001
Product Type: Valve Positioner Module
Product Origin: Sweden
Payment:T/T, Western Union
Weight: 1700g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
ABB V18345-1010521001 Electro-Pneumatic Positioner TZIDC
Product Overview
ABB V18345-1010521001 is an intelligent, configurable electro-pneumatic positioner from the TZIDC series with indicator and operator panel. Features aluminum case IP65 (NEMA 4X) without mechanical indicator. Accepts 4-20mA input with LKS adapter. Double acting with fail freeze action. Electrical connection 1/2-14 NPT and air connection 1/4-18 NPT. Includes plug-in module for analog position feedback 4-20mA two-wire. Weight 1.7 kg.
Model Number Decoder
| Position | Code | Meaning |
|---|---|---|
| Base | V18345 | TZIDC intelligent, configurable with indicator and operator panel |
| Case | 10 | Aluminum Case IP65 (NEMA 4X) No Mechanical Indicator |
| Input/Communication | 1 | 4-20mA with LKS Adapter |
| Protection | 0 | None |
| Action | 5 | Double Acting, Fail Freeze |
| Connections | 2 | Electrical 1/2-14 NPT; Air 1/4-18 NPT |
| Analog Feedback | 1 | Plug-in module 4-20mA two-wire |
| Mech Feedback | 00 | None |
| Design | 1 | Standard |
Technical Specifications
| Parameter | Value |
|---|---|
| Brand | ABB |
| Model | V18345-1010521001 |
| Type | Electro-Pneumatic Positioner TZIDC |
| Action | Double Acting, Fail Freeze |
| Signal Range | 4 to 20 mA |
| Characteristic Curve | Linear, equal percentage 1:25/1:50/25:1/50:1, configurable 20 points |
| Characteristic Deviation | ≤ 0.5% |
| Tolerance Band | 0.3 to 10% adjustable |
| Dead Band | 0.1 to 10% adjustable |
| Resolution A/D | > 4000 steps |
| Sample Rate | 20 ms |
| Temp Influence | ≤ 0.5% per 10°C |
| Vibration Influence | ≤ ±1% up to 10g and 80Hz |
| Seismic | DIN/IEC 68-3-3 Class III |
| Mounting Orientation | No effect |
| Electrical Connection | 1/2-14 NPT |
| Air Connection | 1/4-18 NPT |
| Protection | IP65, NEMA 4X |
| Weight | 1.7 kg |
Installation
Mount positioner with no effect from mounting orientation. Connect 4-20mA signal input. Wire electrical connection at 1/2-14 NPT and air supply at 1/4-18 NPT. Configure characteristic curve via 20 reference points. Adjust tolerance band 0.3 to 10% and dead band 0.1 to 10% per application. Verify IP65 protection seal after installation.
Features
Intelligent configurable positioner with indicator and operator panel. 4-20mA input with LKS adapter. Double acting with fail freeze action. Aluminum case IP65 NEMA 4X. Plug-in analog position feedback 4-20mA two-wire. Characteristic deviation ≤0.5%. Resolution >4000 steps. Sample rate 20 ms. Seismic rated per DIN/IEC 68-3-3 Class III. No effect from mounting orientation.
FAQ
Q1: What is the input signal and action type?
A1: 4-20mA input with LKS adapter. Double acting with fail freeze action. Plug-in analog feedback module 4-20mA two-wire included.
Q2: What are the connection thread sizes?
A2: Electrical connection 1/2-14 NPT. Air connection 1/4-18 NPT. Aluminum case rated IP65 and NEMA 4X.
Q3: What is the characteristic deviation and resolution?
A3: Characteristic deviation ≤0.5%. Resolution >4000 steps. Sample rate 20 ms. Dead band adjustable 0.1 to 10%.
Goşmaça spesifikasiýalar
- Kümüş
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
How Does the Bently Nevada 3500/42M Vibration Module Drift?
This technical guide examines the Bently Nevada 3500/42M vibration module within industrial automation architect...
-
What Causes IC694MDL Fault Codes in GE RX3i PLC Systems?
This guide explains GE RX3i IC694MDL discrete I/O fault codes, key electrical parameters, ESD and torque requirements...
-
What CFC Rules Cut PCS7 Batch Abort Rates Fast?
This article presents enforceable CFC programming governance rules for Siemens PCS7 DCS batch plants, covering b...
-
What Makes the 1769-L3ER Ideal for Compact Skid Automation?
This guide explains how the Allen-Bradley 1769 CompactLogix L3ER bridges the gap between micro PLCs and large DC...
-
Why Do SIL3 Safety Interlocks Still Trip in Industrial Plants?
This article reviews Honeywell Safety Manager SIL3 SIS architecture, wiring and cabinet installation rules, PFDa...
-
How Does Poor Grounding Cause 4-20mA Signal Drift?
This guide explains how MTL signal isolators fail through distortion, drift and EMI in PLC and DCS loops, then d...