Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.
Haryt kody:V18345-1010121001
ABB Electro-Pneumatic Positioner TZIDC IP65 V18345-1010121001
Manufacturer: ABB
Product No.: V18345-1010121001
Product Type: Valve Positioner Module
Product Origin: Sweden
Payment:T/T, Western Union
Weight: 1700g
Shipping port: Xiamen
Warranty: 12 months
Paýlaş
- Çalt eltip berme
- 24/7 goldaw
- Hil üpjünçiligi
Düşündiriş
ABB V18345-1010121001 TZIDC Electro-Pneumatic Positioner
Product Overview
ABB V18345-1010121001 is an intelligent, configurable electro-pneumatic positioner from the TZIDC series with indicator and operator panel. Features varnished aluminum case IP65 (NEMA 4X) for mounting to linear actuators per DIN/IEC 534/NAMUR or rotary actuators per VDI/VDE 3845. Accepts 4-20mA two-wire input with LKS adapter connector plug. Single acting fail safe action. Includes plug-in analog position feedback module 4-20mA. Weight 1.7 kg.
Model Number Decoder
| Position | Code | Meaning |
|---|---|---|
| Base | V18345 | TZIDC intelligent, configurable with indicator and operator panel |
| Case/Mounting | 1 | Varnished aluminum IP65, DIN/IEC 534/NAMUR or VDI/VDE 3845 |
| Input/Communication | 1 | 4-20mA two-wire with LKS adapter connector |
| Explosion Protection | 0 | Without |
| Output/Safe Position | 1 | Single acting, fail safe |
| Connections | 2 | Cable 1/2-14 NPT, Air 1/4-18 NPT |
| Option Modules | 1 | Plug-in analog position feedback 4-20mA |
| Mech Feedback | 0 | Without |
| Design | 1 | Standard |
Technical Specifications
| Parameter | Value |
|---|---|
| Brand | ABB |
| Model | V18345-1010121001 |
| Type | TZIDC Electro-Pneumatic Positioner |
| Action | Single Acting, Fail Safe |
| Output Signal | 4 to 20 mA two-wire |
| Digital Input | 0 to 5V DC (logic 0), 11 to 30V DC (logic 1) |
| Digital Output | 5 to 11V DC per DIN 19234/NAMUR |
| Supply Pressure | 1.4 to 6 bar (20 to 90 psi) |
| Air Consumption | < 0.03 kg/h (0.015 scfm) |
| Housing Material | Aluminum, epoxy resin varnish |
| Protection Class | IP65, NEMA 4X |
| Electrical Connection | 2 threads 1/2-14 NPT or M20x1.5 |
| Pneumatic Connection | G 1/4 or 1/4-18 NPT |
| Screw Terminals | Max 1.0 mm² (options), max 2.5 mm² (analog) |
| Operating Temperature | 40°C to +85°C |
| Humidity Operational | 95% annual average, condensation permissible |
| Humidity Storage | 75% annual average, non condensing |
| Weight | 1.7 kg |
Installation
Mount on linear actuators per DIN/IEC 534/NAMUR or rotary actuators per VDI/VDE 3845. Ready for integral mounting. Connect 4-20mA two-wire input with LKS adapter. Wire electrical connection at 1/2-14 NPT or M20x1.5. Connect air supply at G 1/4 or 1/4-18 NPT with 1.4 to 6 bar pressure. Do not expose terminals to strain. Verify IP65 seal after installation.
Features
Intelligent configurable positioner with indicator and operator panel. Single acting fail safe action for power failure safety. 4-20mA two-wire input with LKS adapter connector. Plug-in analog position feedback module 4-20mA. Air consumption less than 0.03 kg/h independent of supply pressure. Aluminum case with epoxy resin varnish. IP65 NEMA 4X protection. Operating temperature 40°C to +85°C. Humidity tolerance 95% with condensation permissible.
FAQ
Q1: What is the action type and fail position?
A1: Single acting with fail safe action. In case of electrical power failure, the valve moves to its safe position. 4-20mA two-wire input with LKS adapter.
Q2: What are the pneumatic and electrical connection sizes?
A2: Electrical 1/2-14 NPT or M20x1.5. Pneumatic G 1/4 or 1/4-18 NPT. Supply pressure 1.4 to 6 bar (20 to 90 psi).
Q3: What is the air consumption and operating temperature?
A3: Air consumption less than 0.03 kg/h independent of supply pressure. Operating temperature 40°C to +85°C. IP65 NEMA 4X protection.
Goşmaça spesifikasiýalar
- Kümüş
Skalyar (V/f)
Wektor
AC tok bilen işleýän
Satyn alyş gollanmasy
- Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
- Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
- Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
- Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
- Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.
Eltip bermek we gaýtarmak
Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.
Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.
Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Çalt eltip bermek
Asyl senagat awtomatizasiýa şaýlary gyssagly iberiliş üçin bütin dünýä boýunça elýeterlidir.
-
Aňsat gaýtaryşlar
Ygtybarly satuwdan soňky gorag üçin 30 günlük yzyna gaýtarmak goldawy we 12 aýlyk kepilnama.
-
24/7 goldaw
Durnukly we netijeli işleýşi saklamaga ýardam edýän çeýe, professional goldaw.
-
Hakyky we Asyl
100% hakyky, ygtybarly senagat awtomatizasiýasy öndürijilerinden gönüden-göni üpjün edilýär.
Tehniki we satyn alyş gollanmasy
-
How Does the Bently Nevada 3500/42M Vibration Module Drift?
This technical guide examines the Bently Nevada 3500/42M vibration module within industrial automation architect...
-
What Causes IC694MDL Fault Codes in GE RX3i PLC Systems?
This guide explains GE RX3i IC694MDL discrete I/O fault codes, key electrical parameters, ESD and torque requirements...
-
What CFC Rules Cut PCS7 Batch Abort Rates Fast?
This article presents enforceable CFC programming governance rules for Siemens PCS7 DCS batch plants, covering b...
-
What Makes the 1769-L3ER Ideal for Compact Skid Automation?
This guide explains how the Allen-Bradley 1769 CompactLogix L3ER bridges the gap between micro PLCs and large DC...
-
Why Do SIL3 Safety Interlocks Still Trip in Industrial Plants?
This article reviews Honeywell Safety Manager SIL3 SIS architecture, wiring and cabinet installation rules, PFDa...
-
How Does Poor Grounding Cause 4-20mA Signal Drift?
This guide explains how MTL signal isolators fail through distortion, drift and EMI in PLC and DCS loops, then d...