Transform your home with the latest multi-electronics solutions, from intelligent lighting to vOptimize your operations with the Bently Nevada 3500 Monitoring System, offering real-time vibration and machinery condition monitoring to prevent failures and maximize uptime.oice-controlled devices all designed to make life easier, safer, and more connected.
SKU:3BDH000690R1
ABB 3BDH000690R1 CI920AS Advant AC800M Communication Interface
Manufacturer: ABB
Product No.: 3BDH000690R1
Product Type: Communication Interface Module
Product Origin: SE
Payment:T/T, Western Union
Weight: 140g
Shipping port: Xiamen
Warranty: 12 months
Share
- Fast Delivery
- 24/7 Support
- Quality Assurance
Description
Product Overview
The ABB 3BDH000690R1 CI920AS is a high-performance Communication Interface module belonging to the Advant AC800M and S900 I/O series. Engineered for critical process automation, this module facilitates robust data exchange between the controller and I/O stations. Designed specifically for hazardous environments, the CI920AS features ATEX Zone 1 certification and intrinsic safety, ensuring reliable operation in explosive or flammable atmospheres. At a lightweight 0.14 kg, it combines a compact form factor with industrial-grade redundancy for maximum system availability.
Technical Configuration
Model Analysis: 3BDH000690R1 CI920AS
- 3BDH000690R1: Specific ABB global part number for the CI920AS hardware.
- CI920AS: Communication Interface module for S900 I/O within the AC800M architecture.
- Redundancy Mode: Supports dual-channel redundancy to prevent system downtime during signal failure.
- Hazardous Rating: Certified for ATEX Zone 1 and intrinsic safety (IS) applications.
Technical Specifications
| Parameter | Specification |
|---|---|
| Series | Advant AC800M / S900 I/O |
| Unit Weight | 0.14 kg (0.31 lbs) |
| Operating Temperature | -20°C to +60°C |
| Hazardous Certification | ATEX Zone 1 / Intrinsic Safety |
| Corrosion Resistance | ISA-S71.04 G3 Compliant |
| Dimensions (HxWxD) | 104 x 20 x 104 mm |
Installation & Engineering Guide
Maintaining the integrity of the AC800M communication bus requires strict adherence to environmental standards:
- Redundancy Setup: When configured in redundancy mode, ensure that both CI920AS modules are mounted on a compatible redundant terminal base to facilitate automatic bumpless switchover.
- Corrosive Protection: With a G3-compliant coating, this 0.14 kg module is ideal for paper mills or chemical plants. Ensure the enclosure maintains the required humidity levels (max 93%) to prevent condensation.
- Hazardous Area Wiring: All connections in ATEX Zone 1 must follow intrinsic safety wiring protocols. Use blue-colored IS cables to distinguish these circuits from standard power lines.
- Mounting Space: The slim 20mm width allows for high-density installation. However, allow for vertical airflow to maintain the +60°C upper operating limit.
Engineering Advantages
- Explosion Protection: The ATEX Zone 1 rating allows for the module to be installed closer to the field sensors in hazardous locations, reducing long-run cabling costs.
- High Availability: Integrated redundancy ensures that communication with the S900 I/O station continues uninterrupted even if one interface module fails.
- Environmental Resilience: Designed for harsh climates, the CI920AS operates reliably in temperatures as low as -20°C, suitable for outdoor cabinets in colder regions.
- Compliance: Fully RoHS and CE compliant, meeting the latest European standards for environmental protection and electronic safety.
Technical FAQs
Q1: What is the primary function of the CI920AS?
A1: It serves as the bridge between the PROFIBUS DP fieldbus and the S900 I/O modules, providing a certified intrinsically safe interface for hazardous area signals.
Q2: Is the 0.14 kg weight standard for this series?
A2: Yes, the CI920AS is designed to be ultra-lightweight and compact (20mm wide) to maximize cabinet space and minimize mechanical stress on the DIN rail assembly.
Q3: Does this module support G3 harsh environment ratings?
A3: Yes, it meets the ISA-S71.04 G3 standard, which means it is specially coated to resist corrosion from gases like hydrogen sulfide and chlorine.
Additional Specifications
Scalar (V/f)
Vector
AC-powered
Buying Guide
- Confirm the exact model, part number, and specifications before ordering.
- Ensure compatibility with your current machinery or control systems.
- Reach out via sale@etowonauto.com or +8617859788089 for technical assistance.
- Review delivery options, lead times, and shipping requirements.
- Follow manufacturer instructions and best practices during installation.
Shipping And Return
In-stock items are typically dispatched the same business day. For products not currently in stock, dispatch times may vary based on availability. International shipping is available, and shipping costs are calculated according to destination, weight, and carrier selection.
Returns are accepted within 30 days of receipt, provided items are unused and in original condition. Return shipping costs are the responsibility of the customer. Please contact us before returning any item to receive return authorization.
For more details, please review our Shipping & Return Policy.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Fast Shipping
Original industrial automation parts available for prompt shipment worldwide.
-
Easy Returns
30-day return support with a 12-month warranty for reliable after-sales protection.
-
24/7 support
Responsive professional support to help maintain stable and efficient operations.
-
Genuine & Original
100% authentic, sourced directly from trusted industrial automation manufacturers.
Technical & Buying Guide
-
Can DCS Intelligent Regulation Fix Thermal Power Energy Imbalance?
This article explains how intelligent DCS regulation with MPC and cloud-based control solves energy-production imbala...
-
Can Continuous Automation Iteration Cut Factory Costs by 18-25%?
Static industrial control systems create hidden annual cost increases of 18-25%. Phased PLC and DCS program iteration...
-
Can Anti-Interference Hardware End 38% of Automation Downtime?
Field data from chemical, wind, and automotive plants proves that industrial hardware with full IEC 61000-4 EMC certi...
-
How Does Full-Lifecycle Management Optimize PLC and DCS Assets?
Traditional industrial asset management relies on manual logging and reactive troubleshooting, causing 15–20% annual ...
-
Can an Integrated Spare Chain Slash Downtime?
Unplanned equipment failures cost Chinese factories ¥636,000 per hour. Traditional cross-border spare procurement tak...
-
Why Do 30% of Automation Upgrades Fail Due to Integration Gaps?
This technical article explains how digital-intelligent fusion overcomes fragmented workshop operations using industr...