5094-OB16S Allen-Bradley Ple Cat 4 Digital Output Module

Skladda bar (21 sany), ibermek üçin taýýar
  • Manufacturer: Allen-Bradley

  • Product No.: 5094-OB16S

  • Product Type: Output Module

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 200g

  • Shipping port: Xiamen

  • Warranty: 12 months

30 günlük yzyna gaýtaryş syýasaty · 12 aýlyk kepillik
  • Çalt eltip berme
  • 24/7 goldaw
  • Hil üpjünçiligi

Description

Product Overview

The 5094-OB16S is a high-reliability, 16-channel digital sourcing safety output module from the advanced FLEX 5000 I/O platform engineered by Allen-Bradley (Rockwell Automation). Specifically architected for functional safety deployment within critical industrial automation networks, this premium hardware card delivers sixteen safety-rated sourcing outputs operating across an 18 to 32V DC range. Weighing a compact 0.2 kg (0.44 lbs), the module provides distributed safety control and automated diagnostic coverage directly at the machine layer, acting as a core protection node for machinery safety systems.

Core Technical Advantages

  • High-Fidelity Safety Integrity: Attains rigorous global safety certifications up to SIL 3 (IEC 61508), Category 4 / PL e (ISO 13849-1), making it ideal for managing safety-critical emergency stops, light curtains, and safety interlocking perimeters.
  • Rapid Safety Reaction Profile: Features an ultra-responsive, deterministic safety reaction time capped at a maximum of 4.5 ms, ensuring rapid de-energization of hazardous machinery zones when an override or fault condition triggers.
  • Advanced Sourcing Output Design: Provides 16 independent sourcing channels rated at 0.5 Amperes per point, utilizing integrated solid-state pulse testing to continuously monitor field wiring lines for short circuits or cross-faults.
  • Industrial Dielectric Boundary: Equipped with a robust 250V continuous isolation barrier that protects internal backplane logic components from dangerous high-voltage spikes, transient noise, or ground loop interference on the shop floor.

Technical Specifications

Parameter Specification Details
Model Catalog Number 5094-OB16S
Product Line Platform Allen-Bradley FLEX 5000 Safety I/O Platform
Functional Safety Rating SIL 3 / Category 4 / Performance Level e (PL e)
Output Configuration 16-Point Sourcing Safetey Outputs (Current Source to Load)
On-State Operating Voltage 18 to 32V DC field power distribution window
Maximum Output Current 0.5 Amperes maximum continuous load per individual point
Maximum Safety Reaction Time 4.5 milliseconds absolute response threshold
Continuous Isolation Voltage 250V continuous operational testing boundary barrier
Thermal Power Dissipation 3.5 Watts maximum structural energy release
Physical Net Mass 0.2 kg (approx. 0.44 lbs) hardware chassis

Industrial Solutions

  • Robotic Workcell Interlocking: Safeguards automated manufacturing cells by immediately cutting power to robotic arm tooling actuators whenever optoelectronic light curtains or safety gates are breached.
  • Emergency Stop Arrays: Collects and processes localized hardwired E-stop loop buttons across vast packaging facilities, ensuring fail-safe equipment shutdowns under SIL 3 standards.
  • High-Risk Material Converters: Controls heavy hydraulic safety valves and mechanical shear brakes, executing millisecond-accurate torque-off commands to prevent operator injury.
  • Chemical Batching Security: Manages safety shutoff valves in explosive or dangerous fluid handling loops, operating reliably across harsh, volatile plant conditions.

Wiring & Installation

Upstream Power Isolation

Isolate and lock out all primary facility electrical links and secondary auxiliary 24V DC field power lines before handling the module. Working on live safety infrastructure can cause unintended safety trips, lead to localized short-circuits, or introduce corrupted diagnostic data into the active safety controller's memory.

Module Mounting and Seat Verification

Align the 5094-OB16S module with the keyway channels on your pre-installed FLEX 5000 terminal base mounting assembly. Push the module firmly onto the backplane track until the integrated retaining latch clicks home. Verify that the housing sits flush and square against the terminal base to guarantee steady, low-resistance electrical communication.

Field Safety Conductor Termination

Strip your field-side safety wiring conductors carefully to expose the underlying core. Insert copper wires (sized between 22 and 14 AWG) directly into the push-in terminal points, strictly matching your pre-engineered SIL 3 safety channel schematic. Sinking lines from your field actuators must trace back directly to the same master DC common ground rail.

Pulse Testing and Diagnostic Setup

Apply 24V DC field-side actuator power and boot up the GuardLogix control rack. When configuring the module within Studio 5000 Logix Designer, determine if your field devices require active pulse testing; these brief diagnostic pulses verify cable integrity and help identify short circuits or ground faults automatically without disrupting your actuators.

Engineering Advantages

  • Seamless GuardLogix Syncing: Fully compatible with ControlLogix 5580S and CompactLogix 5380S safety controllers, making it easy to configure safety logic using standard safety function blocks.
  • Integrated Smart Pulse Testing: Features onboard pulse-testing algorithms that scan for external wire-to-wire shorts, field cross-talk, and open-circuit states, preventing dangerous unmonitored faults.
  • Studio 5000 Add-On Profiles: Leverages native software integration inside Studio 5000 Logix Designer, reducing engineering layout time and allowing you to adjust safety parameters online.

Technical FAQs

Q1: Why is a max 4.5 ms safety reaction time critical for a SIL 3 output module?
A1: In machinery safety applications, milliseconds save lives. A deterministic 4.5 ms reaction time guarantees that the moment a safety violation occurs, the module drops power almost instantly, helping you meet strict safety distance standards for hazardous machine parts.

Q2: Can I combine copper and aluminum wiring when connecting field devices to the 5094-OB16S?
A2: No. The terminal block clamps are rated strictly for 22 to 14 AWG copper wire. Mixing metals can trigger galvanic corrosion and cause loose connections over time, which compromises your safety loop and can lead to nuisance trips.

Q3: What does a sourcing safety output do if it detects an external short-circuit to ground?
A3: The 5094-OB16S uses smart solid-state switches that detect overcurrent states instantly. If an output wire shorts to ground, the module shuts down that specific channel immediately, signals a diagnostic fault to the main controller, and turns on a front-panel fault LED for easy troubleshooting.

🏷️ Tags: Output Module
  • Red

Scalar (V/f)

Vector

AC-powered

  • Sargyt etmezden ozal takyk modeli, bölek belgisini we aýratynlyklary tassyklaň.
  • Bar bolan enjamyňyz ýa-da dolandyryş ulgamlaryňyz bilen laýyklygyny üpjün ediň.
  • Tehniki kömek üçin sale@etowonauto.com ýa-da +8617859788089 arkaly habarlaşyň.
  • Eltip beriş mümkinçiliklerini, öňdebaryş möhletlerini we iberiş talaplaryny gözden geçiriň.
  • Gurnama wagty öndürijiniň görkezmelerine hem-de iň oňat tejribelere eýeriň.

Stokda bar bolan harytlar adatça şol bir iş gününde ugradylýar. Häzir stokda bolmadyk önümler üçin iberiş wagty elýeterliligine görä üýtgäp biler. Halkara eltip bermek mümkindir we eltip bermek tölegleri barýan ýeriňe, agramyna we daşaýjynyň saýlanmagyna görä hasaplanýar.

Harytlar ulanylman we asyl ýagdaýynda bolmak şerti bilen, alnan gününden başlap 30 günüň içinde yzyna gaýtarmak kabul edilýär. Yzyna iberiş üçin eltip bermek çykdajylary müşderiniň jogapkärçiliginde. Yzyna gaýtarmak baradaky rugsaty almak üçin, haýsydyr bir harydy yzyna ugratmazdan öň biziň bilen habarlaşmagyňyzy haýyş edýäris.

Has giňişleýin maglumat üçin, biziň Iberiş we yzyna gaýtarmak syýasatymyzy.

Önüm jikme-jikliklerini gör

Enjamlaryň ygtybarly işlemegini üpjün ediň

Iň täze köpugurly elektronika çözüwleri bilen öýüňizi özgertmegiňiz mümkin — akylly yşyklandyryşdan başlap, ses arkaly dolandyrylýan enjamlara çenli; bularyň hemmesi durmuşy has aňsat, has howpsuz we has baglanyşykly etmek üçin döredilen. Amallaryňyzy Bently Nevada 3500 Gözegçilik ulgamy bilen optimizirlaň, ol näsazlyklaryň öňüni almak we işleme döwrüni iň ýokary derejede saklamak üçin hakyky wagt režiminde wibrasiýa we enjamyň ýagdaýyna gözegçilik edýär.